Towards 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors
S. J. Smith, J. S. Adams, S. R. Bandler, S. Beaumont, J. A. Chervenak, A. M. Datesman, F. M. Finkbeiner, R. Hummatov, R. L. Kelly, C. A. Kilbourne, A. R. Minius… 展开作者
S. J. Smith, J. S. Adams, S. R. Bandler, S. Beaumont, J. A. Chervenak, A. M. Datesman, F. M. Finkbeiner, R. Hummatov, R. L. Kelly, C. A. Kilbourne, A. R. Miniussi, F. S. Porter, J. E. Sadleir, K. Sakai, N. A. Wakeham, E. J. Wassell, M. C. Witthoeft, K. Ryu
备注:
7 pages, 5 figures. Low Temperature Detectors 18 Conference, Milan Italy
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associated with arrays of individual TESs. Hydras are under development for the next generation of space telescope such as Lynx. Lynx is a NASA concept under study that will combine a < 1 arcsecond angular resolution optic with 100,000-pixel microcalorimeter array with energy resolution of deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and 50 micron pitch are studied. Arrays incorporate, for the first time, microstrip buried wiring layers of suitable pitch and density required to readout a full-scale Lynx array. The resolution from the coadded energy histogram including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at an energy of 1.5 keV for the 25 micron and 50 micron absorber designs respectively. Position discrimination is demonstrated from parameterization of the rise-time.
The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector physics and describe the recent breakthroughs in the TES design that are opening the way towards the fabrication and the read-out of very large arrays of pixels with unprecedented energy resolution. The most challenging low temperature instruments for space- and ground-base experiments will be described.
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-based spectrometers. In this contribution we report on the development and the characterization of a uniform 32$\times$32 pixel array with 140$\times$30 $μ$m$^2$ Ti/Au TESs with Au X-ray absorber. We re…
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would …
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects and phenomena. Signal readout is a critical enabling technology. Multiplexed readout, in which signals from multiple pixels are combined into a single amplifier channel, allows a kilo pixel-scale microc…
The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out system for kilopixel arrays of such TESs. Each TES is voltage biased at a specific frequency in the range 1 to 5 MHz. Isolation between the individual pixels is obtained through very narrow-band (high-Q) lithographic LC resonators. To prevent energy resolution degradation due to intermodulation line noise, the bias frequencies are distributed on a regular grid. …
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electroni…
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from …
ATHENA is a large-class ESA mission selected for launch in 2031. It is designed to address the science theme "The Hot and Energetic Universe", performing X-ray observations (0.2-12 keV) at the L2 Sun-Earth Lagrangian point. The X-IFU is one of the two instruments of the payload. It is a cryogenic spectrometer providing spatially resolved high-resolution spectroscopy. The core of the instrument is a large array of TES microcalorimeters, operated at a 50 mK thermal bath. The X-IFU performances would be strongly degraded by the particle background expected in the L2 environment, thus advanced red…
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 …
Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power. To reach these demanding requirements, every aspect of the TES design has to be optimized. Here we present the experimental results of tests on different devices where the coupling between the x-ray absorber and the TES sensor is varied. In particular, we look at the effects of the diameter of the coupling stems and the distance between the stems and the TES…
When an X-ray is incident onto the silicon absorber array of a detector, it liberates a large number of electrons, which tend to diffuse outward into what is referred to as the charge cloud. This number can vary from tens to thousands across the soft X-ray bandpass (0.1 - 10 keV). The charge cloud can then be picked up by several pixels, and forms a specific pattern based on the exact incident location of the X-ray. We present experimental results on subpixel resolution for a custom H2RG with 36 micron pixels, presented in Bray 2018, and compare the data to simulated images . We then apply the…
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorpora…
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray back…