arXiv 2604.13623physics.flu-dyn
收藏

通过相位锁定循环与壁面振荡优化热对流

Optimizing thermal convection by phase-locking circulation to wall oscillations

Beijing University of Aeronautics and Astronautics(北京航空航天大学);National Supercomputing Center in Shenzhen(国家超级计算深圳中心)

YaLin Zhu, Jian-Chao He, Xi Chen

AI总结:

研究通过相位锁定机制优化热对流,发现最佳频率下大尺度循环与壁面振荡同步,显著提升热传输效率,频率偏离最佳条件会导致循环响应时间变化,影响热传递效率。

摘要:

本文数值研究了在底部板水平振荡作用下二维Rayleigh-Benard对流,Pr=4.3,Ra范围为5e6至1e8,振荡频率f在0.0001至0.5之间。施加的振荡打破经典系统的上下对称性,导致全局热传输有强频率依赖性,最大努塞尔数增强超过未受控情况的60%。核心控制效率在于相位锁定机制:在最佳频率下,大尺度循环(LSC)的固有响应时间通过体积平均角动量符号恢复锁定精确到壁面振荡周期,使LSC反转完美同步。偏离最佳条件会导致明显不匹配;频率超过最佳时LSC响应时间显著变长,低于最佳时则显著变短。相比之下,边界层速度仅跟随壁面振荡,无法区分控制效率。傅里叶模态分析显示,在最佳频率下,单卷模式在整个周期内主导,促进高效烟流传输,而更高频率导致不完全反转,更低频率产生双卷结构,降低热传递效率。此频率锁定机制在所研究的整个Rayleigh数范围内持续存在,为热驱动湍流的主动控制策略提供稳健见解。

英文摘要:

This study numerically investigates two-dimensional Rayleigh-Benard convection subjected to horizontal oscillation of the bottom plate, with Prandtl number Pr=4.3, Rayleigh numbers Ra ranging from 5e6 to 1e8, and oscillation frequencies f between 0.0001 and 0.5. The imposed oscillation breaks the up-down symmetry of the classical system, inducing a strong frequency-dependent response in global heat transport, with the maximum Nusselt number enhancement exceeding 60% compared to the uncontrolled case. Central to this control efficiency is a phase-locking mechanism: at the optimal frequency, the intrinsic response time of the large-scale circulation (LSC), quantified by the sign-recovery of volume-averaged angular momentum, locks precisely to the wall oscillation period, enabling perfectly synchronized LSC reversals. Deviations from this optimal condition lead to a marked mismatch; the LSC response time becomes substantially longer when frequency exceeds the optimum and significantly shorter when frequency falls below it. In contrast, boundary layer velocities simply follow the wall oscillations and fail to distinguish control efficiency. Fourier mode analysis reveals that at the optimal frequency, a single-roll mode remains dominant throughout the cycle, facilitating efficient plume transport, whereas higher frequencies yield incomplete reversals and lower frequencies produce a double-roll structure that diminishes heat-transfer efficiency. This frequency-locking mechanism is shown to persist for optimal controls across the entire investigated Rayleigh number range, thus offering robust insight for active control strategies in thermally driven turbulent flows.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑