arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2603.24992cs.CV

C2W-Tune:用于3D晚期钆增强磁共振中薄心房壁分割的腔体到壁迁移学习

C2W-Tune: Cavity-to -Wall Transfer Learning for Thin Atrial Wall Segmentation in 3D Late Gadolinium-enhanced Magnetic Resonance

Systems and Computer Engineering, Carleton University(卡莱顿大学系统与计算机工程系);Department of Radiology, University of Ottawa(渥太华大学放射科部)

Yusri Al-Sanaani, Rebecca Thornhill, Sreeraman Rajan

AI总结:

本文提出C2W-Tune框架,通过高精度左心房腔体模型提升薄壁分割精度,实验显示在2018年左心房分割挑战数据集上,Dice系数和边界误差显著降低。

摘要:

准确分割3D晚期钆增强MRI(LGE-MRI)中的左心房(LA)壁对于壁厚度映射和纤维化定量至关重要,但因壁薄、解剖复杂和对比度低而具有挑战性。我们提出C2W-Tune,一种两阶段腔体到壁迁移框架,利用高精度LA腔体模型作为解剖先验,改进薄壁分割。使用带有ResNeXt编码器和实例归一化的3D U-Net,第一阶段预训练网络分割LA腔体,学习稳健的房室表示。第二阶段转移这些权重并调整网络进行LA壁分割,通过渐进式层解冻计划保留内膜特征并实现壁特异性细化。在2018年LA分割挑战数据集上的实验显示,与从头训练的基线模型相比,壁Dice系数从0.623提升至0.814,1毫米表面Dice系数从0.553提升至0.731。边界误差显著降低,95百分位Hausdorff距离(HD95)从2.95毫米降至2.55毫米,平均对称表面距离(ASSD)从0.71毫米降至0.63毫米。此外,即使在减少监督(70个训练体积从相同训练池采样)的情况下,C2W-Tune仍实现了Dice分数0.78和HD95 3.15毫米,保持了竞争性表现并超过了多类基准通常报告的Dice分数约0.6-0.7。这些结果表明,具有受解剖约束的任务迁移与受控微调能提高3D LGE-MRI中薄LA壁分割的边界精度。

英文摘要:

Accurate segmentation of the left atrial (LA) wall in 3D late gadolinium-enhanced MRI (LGE-MRI) is essential for wall thickness mapping and fibrosis quantification, yet it remains challenging due to the wall's thinness, complex anatomy, and low contrast. We propose C2W-Tune, a two-stage cavity-to-wall transfer framework that leverages a high-accuracy LA cavity model as an anatomical prior to improve thin-wall delineation. Using a 3D U-Net with a ResNeXt encoder and instance normalization, Stage 1 pre-trains the network to segment the LA cavity, learning robust atrial representations. Stage 2 transfers these weights and adapts the network to LA wall segmentation using a progressive layer-unfreezing schedule to preserve endocardial features while enabling wall-specific refinement. Experiments on the 2018 LA Segmentation Challenge dataset demonstrate substantial gains over an architecture-matched baseline trained from scratch: wall Dice improves from 0.623 to 0.814, and Surface Dice at 1 mm improves from 0.553 to 0.731. Boundary errors were substantially reduced, with the 95th-percentile Hausdorff distance (HD95) decreasing from 2.95 mm to 2.55 mm and the average symmetric surface distance (ASSD) from 0.71 mm to 0.63 mm. Furthermore, even with reduced supervision (70 training volumes sampled from the same training pool), C2W-Tune achieved a Dice score of 0.78 and an HD95 of 3.15 mm, maintaining competitive performance and exceeding multi-class benchmarks that typically report Dice values around 0.6-0.7. These results show that anatomically grounded task transfer with controlled fine-tuning improves boundary accuracy for thin LA wall segmentation in 3D LGE-MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑