基于数据驱动的多级水轮机不稳流模态分解分析

Data-Driven Modal Decomposition Analysis of Unsteady Flow in a Multi-Stage Turbine

University of California, Irvine(加州大学尔湾分校)

Yalu Zhu, Feng Liu

AI总结:

本文对比了POD与四种DMD方法在多级水轮机不稳流分析中的性能,发现基于幅值、Tissot准则及SP-DMD的DMD方法在重建精度上与POD相当,但POD模式的时间演化无法准确反映系统动态特征。

摘要:

两种数据驱动的模态分析方法,即proper orthogonal decomposition(POD)和dynamic mode decomposition(DMD),被应用于分析通过求解雷诺平均纳维-斯托克斯(RANS)方程得到的1.5级轴向水轮机不稳流。POD和四种DMD变体在下游定子中的减少阶重建压力、主导模态形状及这些主导模态的动态特征进行了比较。发现基于幅值准则、Tissot准则和稀疏促进DMD(SP-DMD)的DMD方法在重建精度上与POD相当,而频率准则对当前问题不适用。第二和第三POD和DMD模式捕捉了定子中的主导压力波动结构,对应的POD和DMD空间模式有相似性。不稳流主要由具有高幅值和低频率的中性DMD模式支配,这些频率对应于由转子通过频率驱动的基本和谐波频率。尽管POD分析为原始快照提供了准确的重建,但每个POD模式的时间演化并不反映系统的真正动态特征。特别是,它们错误地代表了问题的基本频率。此外,还探讨了下游定子中主导模式与水轮机绝热效率之间的相关性,不同定子时钟配置下发现,具有更高绝热效率的时钟配置对应第二和第三DMD模式对的更大空间和时间成分,以及类似的第二POD模式。

英文摘要:

Two data-driven modal analysis approaches, proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD), are applied to analyze the unsteady flow obtained by solving the Reynolds-averaged Navier-Stokes (RANS) equations in a 1.5-stage axial turbine. The reduced-order reconstructed pressure, dominant mode shapes, and dynamic features of these dominant modes in the downstream stator of the turbine are compared between POD and four DMD variants. It is found that the DMD methods based on the amplitude criterion, the Tissot criterion, and the sparsity-promoting DMD (SP-DMD) achieve reconstruction accuracy comparable to that of POD, while the frequency criterion proves unsuitable for the present problem. The second and third POD and DMD modes capture the dominant pressure fluctuation structures within the stator, and there is similarity between the corresponding POD and DMD spatial modes. The unsteady flow is primarily governed by neutral DMD modes characterized by high amplitudes and low frequencies corresponding to the basic and harmonic frequencies driven by the rotor passing frequency. While the POD analysis provides accurate reconstruction for the original snapshots, the time evolution of each POD mode does not reflect the true dynamic feature of the system. In particular, they misrepresent the fundamental frequencies of the problem. In addition, the correlations between the dominant modes in the downstream stator and the turbine adiabatic efficiency are explored across different stator clocking configurations. It is found that a clocking configuration with higher adiabatic efficiency at 50% span corresponds to a larger spatial and time component of the second and third DMD mode pair, and similarly a larger second POD mode.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑