arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2603.05101astro-ph.IMphysics.optics
收藏

利用仅强度测量的同时误对准和模式不匹配传感在光学腔体中

Simultaneous Misalignment and Mode Mismatch Sensing in Optical Cavities Using Intensity-Only Measurements

Université Paris Cité(巴黎西岱大学);CNRS, Astroparticule et Cosmologie(法国国家科学研究中心,粒子与宇宙学研究所);Institute for Gravitational Wave Astronomy, Henan Academy of Sciences(河南省科学院引力波天文研究院)

Liu Tao, Eleonora Capocasa, Yuhang Zhao, Jacques Ding, Isander Ahrend, Matteo Barsuglia

AI总结:

本文提出一种基于深度学习的两阶段框架,利用仅强度图像进行光学腔体的误对准和模式不匹配传感,实现高精度波前传感和模式不匹配诊断,提升精密光学系统的稳定性和灵敏度。

摘要:

精确感知和控制空间模式内容对于精密光学系统性能至关重要,特别是在干涉仪引力波探测器中,误对准和模式不匹配可能导致显著的光学损耗和降质的量子噪声抑制。传统方法包括异频波前传感和相位相机技术,但受限于硬件复杂性和参考光束重叠的系统误差。本文提出了一种新颖的两阶段深度学习管道,基于仅强度图像进行稳健的光束诊断。第一阶段,多强度图像卷积神经网络(CNN)进行准确的模式分解,恢复畸变光束的复杂模态内容。第二阶段,预测的模式系数被输入到下游回归网络中,同时估计所有八个自由度(DoFs)相关的误对准和模式不匹配,包括光束倾斜、横向偏移以及横向方向的光束腰大小和位置不匹配。所提出的基于CNN的框架在模式分解阶段的平均绝对误差(MAE)为0.0034,传播到最终阶段的总MAE为0.0062。这对应于每个自由度的平均残余光学损耗为39 ppm(总310 ppm)。该方法仅依赖标准CCD成像,对随机强度噪声具有鲁棒性,消除了复杂干涉仪硬件的需求。结果表明,所提出的深度学习管道能够实现实时高精度波前传感和模式不匹配诊断,提供了一种可扩展且硬件高效的工具,用于改进精密光学系统的稳定性和灵敏度。

英文摘要:

Precise sensing and control of spatial mode content is essential for the performance of precision optical systems, particularly interferometric gravitational-wave detectors, where misalignment and mode mismatch can lead to significant optical losses and degraded quantum noise suppression. Conventional approaches, including heterodyne wavefront sensing and phase camera techniques, are effective but can be limited by hardware complexity and systematic uncertainties arising from restricted reference-beam overlap. This paper presents a novel two-step deep learning pipeline for robust beam diagnostics based solely on beam intensity images. In the first stage, a multi-intensity-image convolutional neural network (CNN) performs accurate mode decomposition, recovering the complex modal content of distorted beams. In the second stage, the predicted mode coefficients are fed into a downstream regression network that simultaneously estimates all eight degrees of freedom (DoFs) associated with misalignment and mode mismatch, including beam tilt, lateral offset, and waist size and position mismatches in both transverse directions. The proposed CNN-based framework achieves a mean absolute error (MAE) of 0.0034 in the mode decomposition stage, which propagates to a total MAE of 0.0062 in the recovered beam imperfection parameters at the final stage. This corresponds to an average residual optical loss of 39 ppm per DoF (310 ppm total). This approach relies only on standard CCD imaging and is robust to random intensity noise, eliminating the need for complex interferometric hardware. The results demonstrate that the proposed deep learning pipeline enables real-time, high-accuracy wavefront sensing and mode-mismatch diagnostics, providing a scalable and hardware-efficient tool for improving the stability and sensitivity of precision optical systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑