arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2501.11528physics.opticsastro-ph.IMgr-qcphysics.ins-det
收藏

可调谐相干激光干涉仪:演示40dB的杂光抑制和与共振光学腔的兼容性

Tunable coherence laser interferometry: demonstrating 40dB of straylight suppression and compatibility with resonant optical cavities

University of Hamburg(汉堡大学);Max Planck Institute for Gravitational Physics (Albert Einstein Institute)(马克斯·普朗克引力物理研究所(爱因斯坦研究所));Leibniz University Hannover(汉诺威莱布尼茨大学);Helmut Schmidt University(赫尔穆特·施密特大学);E.L. Ginzton Laboratory, Stanford University(斯坦福大学Ginz顿实验室)

Daniel Voigt, Leonie Eggers, Katharina-Sophie Isleif, Sina M. Koehlenbeck, Melanie Ast, Oliver Gerberding

AI总结:

本研究通过伪随机噪声相位调制调节激光相干性,实现40dB杂光抑制,并验证了在共振光学腔中使用该技术的可行性。

摘要:

激光连续波干涉仪的主要限制是寄生光场,如鬼束、散射或杂光,这些光场会引起非线性噪声。这在基于激光干涉的地面引力波探测器中尤其相关。增加灵敏度,特别是在低于10Hz的频率范围内,受到寄生光子影响的威胁。这些光子可以将低频扰动上转换为相位和幅度噪声。通过人工调节激光的相干性,使用伪随机噪声(PRN)相位调制,可以抑制寄生光场的影响。由于这些光场经过不同路径传播,因此不牺牲相干性以换取有意干涉。我们通过实验验证了该技术的可行性,在迈克尔逊干涉仪中实现了低于30厘米的人工相干长度的噪声抑制水平为40dB。我们探讨了抑制程度如何依赖于延迟不匹配和PRN序列长度。我们还证明了光学共振腔可以在PRN调制下运行,通过测量带有和不带此类调制的线性腔体的行为。通过匹配共振腔的往返长度和PRN序列重复长度,可以恢复经典的响应。

英文摘要:

A major limitation of laser interferometers using continuous wave lasers are parasitic light fields, such as ghost beams, scattered or stray light, which can cause non-linear noise. This is especially relevant for laser interferometric ground-based gravitational wave detectors. Increasing their sensitivity, particularly at frequencies below 10 Hz, is threatened by the influence of parasitic photons. These can up-convert low-frequency disturbances into phase and amplitude noise inside the relevant measurement band. By artificially tuning the coherence of the lasers, using pseudo-random-noise (PRN) phase modulations, this influence of parasitic fields can be suppressed. As it relies on these fields traveling different paths, it does not sacrifice the coherence for the intentional interference. We demonstrate the feasibility of this technique experimentally, achieving noise suppression levels of 40 dB in a Michelson interferometer with an artificial coherence length below 30 cm. We probe how the suppression depends on the delay mismatch and length of the PRN sequence. We also prove that optical resonators can be operated in the presence of PRN modulation by measuring the behavior of a linear cavity with and without such a modulation. By matching the resonators round-trip length and the PRN sequence repetition length, the classic response is recovered.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑