In this paper, we present our submission to the LUMIR25 task of Learn2Reg 2025, which ranked 1st overall on the test set. Extended from LUMIR24, this year's task focuses on zero-shot registration under domain shifts (e.g., high-field MRI, pathological brains, and various MRI contrasts), while the training data comprises only in-domain T1-weighted brain MRI. We start with a meticulous analysis of LUMIR24 winners to identify the main contributors to strong monomodal registration performance. We highlight the importance of registration-specific inductive biases, including multi-resolution pyramids, inverse and group consistency, topological preservation or diffeomorphism, and correlation-based correspondence establishment. To further generalize to diverse contrasts, we employ three simple but effective strategies: (i) a multimodal loss based on the modality-independent neighborhood descriptor (MIND), (ii) intensity randomization for unseen contrast augmentation, and (iii) lightweight instance-specific optimization (ISO) on feature encoders at inference time. On the validation set, the proposed approach substantially improves T1-T2 registration accuracy, demonstrating robust cross-contrast generalization without relying on explicit image synthesis. These results suggest a practical step toward a registration foundation model that can leverage a single training domain yet remain robust across domain shifts.
Initialize globally before acting locally: Enabling Landmark-free 3D US to MRI Registration
Technische Universität München(慕尼黑工业大学);Konica Minolta Laboratory Europe(柯尼卡美能达欧洲实验室);Johns Hopkins University(约翰斯·霍普金斯大学);Trinity College Dublin(都柏林圣三一学院)
Motion correction of dynamic contrast enhanced MRI of the liver
Center for Image Sciences, University Medical Center Utrecht, the Netherlands(荷兰乌得勒支大学医学中心影像科学中心);Department of Radiology, University Medical Center Utrecht, the Netherlands(荷兰乌得勒支大学医学中心放射科)
Groupwise Registration with Physics-Informed Test-Time Adaptation on Multi-parametric Cardiac MRI
Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, United States Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Germany Department of Imaging Physics, Delft University of Technology, Netherlands TUM School of Computation, Information;Technology, Technische Universität München, Germany Department of Surgery, Taipei Veterans General Hospital, Taiwan
GSMorph: Gradient Surgery for cine-MRI Cardiac Deformable Registration
University of Leeds(利兹大学);Radboud University Medical Centre(拉德堡德大学医学中心);Netherlands Cancer Institute(荷兰癌症研究所);Shenzhen University(深圳大学);Shenzhen RayShape Medical Technology Co., Ltd(深圳睿心医疗科技有限公司)
Learning accurate rigid registration for longitudinal brain MRI from synthetic data
1 Division of Biomedical Imaging, KTH Royal Institute of Technology, Huddinge, Sweden 2 Athinoula A.\ Martinos Center for Biomedical Imaging, Charlestown, USA 3 Department of Radiology, Massachusetts General Hospital, Boston, USA 4 Department of Radiology, Harvard Medical School, Boston, USA 5 Computer Science \& Artificial Intelligence Laboratory, MIT, Cambridge, USA
Joint Progressive and Coarse-to-fine Registration of Brain MRI via Deformation Field Integration and Non-Rigid Feature Fusion
Britton Chance Center for Biomedical Photonics(布里顿·钱斯生物医学光子学研究中心);Wuhan National Laboratory for Optoelectronics(武汉光电国家研究中心);MoE Key Laboratory for Biomedical Photonics(教育部生物医学光子学重点实验室);Collaborative Innovation Center for Biomedical Engineering(生物医学工程协同创新中心);School of Engineering Sciences, Huazhong University of Science and Technology(华中科技大学工程科学学院)
To deform or not: treatment-aware longitudinal registration for breast DCE-MRI during neoadjuvant chemotherapy via unsupervised keypoints detection
Radboud University Medical Centre(拉德堡德大学医学中心);The Netherlands Cancer Institute(荷兰癌症研究所);Macao Polytechnic University(澳门理工大学);Maastricht University Medical Centre(马斯特里赫特大学医学中心)
Deep learning-based group-wise registration for longitudinal MRI analysis in glioma
Erasmus MC(伊拉斯姆斯大学医学中心);Medical Delta(医疗三角洲);Delft University of Technology(代尔夫特理工大学);Amsterdam UMC / VU Medical Center(阿姆斯特丹大学医学中心/自由大学医学中心);Princess Máxima Center for Pediatric Oncology(马克西玛公主儿童肿瘤中心);The Jackson Laboratory for Genomic Medicine(杰克逊基因组医学实验室)
Robust joint registration of multiple stains and MRI for multimodal 3D histology reconstruction: Application to the Allen human brain atlas
University College London(伦敦大学学院);Inria(法国国家信息与自动化研究所);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);Massachusetts Institute of Technology(麻省理工学院)
Weakly-supervised Biomechanically-constrained CT/MRI Registration of the Spine
Technische Universität München(慕尼黑工业大学);ScintHealth GmbH(ScintHealth有限公司);Reply SpA(Reply股份公司);Helmholtz Zentrum München(慕尼黑亥姆霍兹中心);Helmholtz AI(亥姆霍兹人工智能研究所)
TimeFlow: Temporal Conditioning for Longitudinal Brain MRI Registration and Aging Analysis
Technical University of Munich, TUM University Hospital(慕尼黑工业大学,慕尼黑工业大学附属医院);Munich Center for Machine Learning (MCML)(慕尼黑机器学习中心);Munich Data Science Institute (MDSI)(慕尼黑数据科学研究所);Imperial College London(伦敦帝国理工学院)
Diffeomorphic Multi-Resolution Deep Learning Registration for Applications in Breast MRI
Auckland Bioengineering Institute(奥克兰生物工程研究所);University of Auckland(奥克兰大学);Faculty of Medical and Health Sciences(医学与健康科学学院);MGH/HST Martinos Center for Biomedical Imaging(麻省总医院/哈佛健康科学技术生物医学成像马蒂诺斯中心);Harvard Medical School(哈佛医学院);MIT(麻省理工学院)
Multimodal Deformable Image Registration for Long-COVID Analysis Based on Progressive Alignment and Multi-perspective Loss
University of Oxford(牛津大学);Nuffield Department of Population Health, University of Oxford(牛津大学纳菲尔德人口健康系);Big Data Institute, University of Oxford(牛津大学大数据研究所);Oxford University Hospitals NHS Foundation Trust(牛津大学医院 NHS 基金会信托基金);Oxford Radiology Research Unit(牛津放射学研究单元)
Variational U-Net with Local Alignment for Joint Tumor Extraction and Registration (VALOR-Net) of Breast MRI Data Acquired at Two Different Field Strengths
University of Peshawar(白沙瓦大学);Danube Private University(多瑙河私立大学);University of Engineering & Technology, Peshawar(白沙瓦工程与技术大学);Medical University of Vienna(维也纳医科大学);Karl Landsteiner Society(卡尔·兰施泰纳学会);University of Cambridge(剑桥大学)
Deformable MRI Sequence Registration for AI-based Prostate Cancer Diagnosis
Radboudumc(拉德堡德大学医学中心);Fraunhofer MEVIS(弗劳恩霍夫梅维斯研究所);Universität zu Lübeck(吕贝克大学);University Medical Center Groningen(格罗宁根大学医学中心);Netherlands Cancer Institute(荷兰癌症研究所);Norwegian University of Science and Technology(挪威科技大学)
Uncertainty-Aware Cortical Surface Reconstruction and Spherical Registration for Heterogeneous Brain MRI
Danish Research Centre for Magnetic Resonance, Department of Radiology and Nuclear Medicine, Copenhagen University Hospital – Amager and Hvidovre(丹麦磁共振研究中心,放射科与核医学科,哥本哈根大学医院-阿马格和维多弗);Department of Health Technology, Technical University of Denmark(技术丹麦大学健康技术系);Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital(阿蒂努拉·A·马丁诺斯生物医学成像中心,麻省总医院);Computer Science and Artificial Intelligence Lab, Massachusetts Institute of Technology(麻省理工学院计算机科学与人工智能实验室);Department of Radiology, Harvard Medical School(哈佛医学院放射学系);Hawkes Institute, University College London(霍克斯研究所,伦敦大学学院)
DRIMET: Deep Registration for 3D Incompressible Motion Estimation in Tagged-MRI with Application to the Tongue
Johns Hopkins University(约翰斯·霍普金斯大学);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);University of Maryland School of Medicine(马里兰大学医学院)
Deformable Medical Image Registration with Effective Anatomical Structure Representation and Divide-and-Conquer Network
National Engineering Laboratory for Integrated Aero-Space-Ground-Ocean Big Data Application Technology, School of Computer Science and Engineering, Northwestern Polytechnical University(集成空天地海大数据应用技术国家工程实验室,计算机科学与工程学院,西北工业大学)
Deep learning and classical computer vision techniques in medical image analysis: Case studies on brain MRI tissue segmentation, lung CT COPD registration, and skin lesion classification
University of Exeter(埃克塞特大学);Georgia Institute of Technology(佐治亚理工学院);Emory University(埃默里大学);Sorbonne Université(索邦大学)
GuidedMorph: Two-Stage Deformable Registration for Breast MRI
Department of Electrical and Computer Engineering, Duke University(电子工程系,杜克大学);Department of Biostatistics & Bioinformatics, Duke University(生物统计学与生物信息学系,杜克大学);Department of Health Outcomes and Biomedical Informatics, College of Medicine, University of Florida(健康结果与生物医学信息学系,医学院,佛罗里达大学)
Generative Aging of Brain Images with Diffeomorphic Registration
KTH Royal Institute of Technology(瑞典皇家理工学院);Karolinska Institute(卡罗林斯卡学院);Karolinska University Hospital(卡罗林斯卡大学医院);University Fernando Pessoa Canarias(费尔南多·佩索阿加那利群岛大学);King’s College London(伦敦国王学院)