Charge collection efficiency of thimble ionization chambers exposed to ultra-high dose per pulse
Universidade de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学);Physikalisch-Technische Bundesanstalt(德国联邦物理技术研究院);Instituto de Investigacion Sanitaria de Santiago (IDIS)(圣地亚哥卫生研究所);Complexo Hospitalario Universitario de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学医院综合体)
José Paz-Martín, Andreas Schüller, Marvin Apel, Araceli Gago-Arias, Juan Pardo-Montero, Faustino Gómez
Background: Commercially available ionization chambers (ICs) exposed to ultra-high dose per pulse (UHDP) exhibit deviations from a linear dose response due to volume recombination. Simulation models have been developed to describe the charge collection efficiency (CCE) but focused on parallel-plate ICs. This study aims to measure and simulate the CCE and polarity effect of thimble ICs in UHDP. Methods: The response of two PinPoint3D T31022 (PP3D) and two PinPoint T31023 (PP) ICs was investigated experimentally at the national metrology institute of Germany (PTB). The ICs were irradiated using the UHDP reference electron beam with dose per pulse up to 9.3 Gy for different voltages. A novel finite element code capable of simulating 1D and 2D geometries was developed. Results: Thimble ICs exhibit a pronounced polarization effect when irradiated with UHDP. When the sign of the collected charge is negative, the CCE is larger than when it is positive. The major contribution to the polarity effect can be attributed to the polarity-dependent charge transport and recombination. Experimental and simulated CCE (polarity effect correction factor) agrees within 1.4 % (7.0 %) and 1.6 % (3.2 %) for the PP3D and PP ICs, respectively. The CCE of parallel-plate and thimble ICs is related through a geometrical rule. Conclusions: The PP IC shows greater CCE due to its smaller external radius. The numerical model is able to satisfactory reproduce the actual CCE and polarity effect for these two chambers. At UHDP, thimble ICs should be used with caution due to their large polarity effect.
Surface and buildup region dose measurements with Markus parallel-plate ionization chamber, Gafchromic EBT3 film and MOSFET detector for high energy photon beams
本研究的目的是调查表面和建立区域剂量为6 MV和15 MV光子束使用马库斯平行板电离室,GafChromic EBT 3膜,和MOSFET探测器不同的字段大小和光束角度。在水等效固体体模中,在表面和6 MV和15 MV光子束的积聚区域中,在100 cm的源-探测器距离处,针对5 x 5、10 x 10和20 x 20 cm 2的射野尺寸和0、30、60和80光束角度进行测量。对于Markus室、EBT 3膜和MOSFET探测器,发现使用6 MV光子束对于10 × 10 cm 2场尺寸的表面剂量分别为20.3%、18.8%和25.5%。对于Markus室、EBT 3膜和MOSFET探测器,使用15 MV光子束对于10 × 10 cm 2场尺寸的表面剂量分别为14.9%、13.4%和16.4%。所有剂量计的表面剂量随射野大小而增加。随着入射辐射束的角度变得更加倾斜,表面剂量增加。剂量计的有效测量深度各不相同;因此,测量结果可能不同。该问题可能导致表面和累积剂量测定错误,必须予以考虑。
Characterization of a novel plastic scintillation detector for in vivo electron dosimetry
University Medical Centre Mannheim, Heidelberg University(海德堡大学曼海姆医学中心);DKFZ-Hector Cancer Institute, University Medical Centre Mannheim(德国癌症研究中心-海克特癌症研究所,曼海姆医学中心);Mannheim Institute for Intelligent Systems in Medicine (MIISM), Medical Faculty Mannheim, Heidelberg University(海德堡大学曼海姆医学院曼海姆智能医学系统研究所)
Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination
Université libre de Bruxelles (ULB)(布鲁塞尔自由大学);Ion Beam Applications SA(离子束应用公司)
Low noise optimization of an electron beam current transformer for conventional radiotherapy up to ultra high dose rate irradiations
超高剂量率电子束,也称为FLASH放射治疗,在一些临床前癌症治疗研究中变得越来越重要。然而,由于在辐照会话期间使用的剂量率,迄今为止不存在实时剂量监测装置。在这项工作中,我们提出了一个束电流互感器(BCT)的发展,从铁磁组件的选择和实现的屏蔽的前端电子设计的基础上的跨阻抗电路,以执行低噪声优化的检测器。BCT样机能够监测1.2 \textmu A ~ 200 mA的束流,信号的上升时间常数优于20 ns,下降速率低于0.05 $\cdot$ s $^{-1}$。初步的现场测量也提出。目标是将实时测量射束电流的BCT系统与监测射束形状和位置的电离室相结合,以提供可靠的剂量监测系统。
Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance
设计、制造和测试了用于放射治疗质量保证的液体异辛烷(C $_{8}$ H $_{18}$)填充电离线阵。探测器由128个像素组成,每个像素的面积为1.7 mm $\times$ 1.7 mm,间隙为0.5 mm。小像素尺寸使探测器非常适合高梯度射束轮廓,如强度调制放射治疗(IMRT)和放射外科中存在的那些。作为读出电子设备,我们使用由CCLRC开发的带有Xchip的X射线数据采集系统(XDAS)。为了优化器件的操作,已经进行了关于收集效率对极化电压和剂量率的依赖性的研究。在第一次测试中,我们研究了剂量率和能量依赖性以及信号再现性。在固体水中,剂量率依赖性低于2.5%,直至5 Gy min $^{-1}$,能量依赖性低于2.1%,直至20 cm深度。几个矩形领域的输出因子和半影已被测量的线性阵列,并与0.125厘米的$^{3}$空气电离室和射线照相胶片,分别获得的结果进行了比较。最后,我们已经获得了配置文件的调强放射治疗领域和虚拟楔形。这些配置文件也进行了比较与射线照相胶片测量。所有的比较都显示出良好的对应关系。在测试期间(约三个月),信号再现性在2%以内。该装置已被证明具有良好的空间分辨率和信噪比的在线验证治疗光束的能力。