Purpose: The purpose of the work was experimental investigations of the breast dose distributions with adaptive filtration. Adaptive filtration reduces detector dynamic range and improves image quality. The adaptive filter with predetermined shape is placed at the x-ray beam such that the x-ray intensity at the detector surface is flat. However, adaptive filter alters the mean dose to the breast, as well as volume distribution of the dose. Methods: The dose was measured using a 14 cm diameter cylindrical acrylic breast phantom. An acrylic adaptive filter was fabricated to match the 14 cm diameter of the phantom. The dose was measured using ion chamber inserted into holes distributed along the radius of the phantom from the center to the edge. The radial distribution of dose was measured and fitted by an analytical function and the volume distribution and mean value of dose was calculated. The measurements were performed at 40, 60, 90, and 120 kVp tube voltages and 6.6 mGy air kerma. Results: The adaptive filter decreased mean breast dose by a factor of 1.6-2.2 depending on the tube voltage. To maintain image quality, the tube output was increased by these factors when adaptive filter was used. The adaptive filter provided uniform volume distribution of dose at 40 kVp and 60 kVp tube voltages, but the distribution was non-uniform at 90 kVp and 120 kVp tube voltages. Conclusion: While adaptive filtration helps with detector dynamic range, CT number uniformity, and CT noise uniformity, the volume non-uniformity of the dose with adaptive filter depends on tube voltage. On the other hand, at the same average breast dose, volume non-uniformity of the dose with adaptive filter was not higher that that without adaptive filter. The results allowed also to determine necessary dose increase factor to compensate for x-ray absorption in the adaptive filter.
New dosimetry planning strategy based on continuous dose gradient used to reduce dose estimation errors due to respiratory motion in breast radiation therapy
A volumetric Modulated Arc Therapy (VMAT) combined with deep inspiration breath hold (DIBH) technique for adjuvant irradiation for left sided breast cancer
Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising
The University of Melbourne(墨尔本大学);The University of Sydney(悉尼大学);Eastern Health(东部健康);Monash Health(莫纳什健康);Monash University(莫纳什大学);Australian Synchrotron, ANSTO(澳大利亚同步辐射中心,ANSTO);Commonwealth Scientific and Industrial Research Organisation(澳大利亚联邦科学与工业研究组织)
Organ dose optimization for a point-of-care forearm X-ray photon-counting CT
Institut of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne (UNIL)(放射物理研究所(IRA),洛桑大学医院(CHUV)和洛桑大学(UNIL));Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL)(诊断与介入放射科,洛桑大学医院(CHUV)和洛桑大学(UNIL));University of Otago(奥塔哥大学)
Breast biomecanical modeling for compression optimization in digital breast tomosynthesis
乳房X光检查是一种特殊类型的乳房成像,使用低剂量X射线来检测早期癌症。在检查过程中,妇女的乳房被压缩在两个板之间,直到获得几乎均匀的乳房厚度。该技术提高了图像质量并减少了剂量,但也可能是患者不适的来源,有时甚至是疼痛。因此,允许减少乳房压迫的替代技术是潜在的兴趣。这项工作的目的是开发一个三维生物力学有限元(FE)乳房模型,以分析各种乳房压缩策略及其对图像质量和辐射剂量的影响。利用ANSYS软件对该模型进行了大变形模拟。由于重力和边界条件(胸部解剖结构,MRI机内患者的位置),特别注意模型中残余应力的计算。先前开发的生物力学乳房模型通过仅对脂肪和纤维腺体组织建模来使用简化的乳房解剖结构(Rajagopal等人,Wiley Intermittep Rev:Syst Biol Med 2:293- 304,2010)。然而,乳房再造手术已经证明了悬韧带和乳房筋膜对乳房力学的重要性(Lockwood in Plast Reconstr Surg 103:1411- 1420,1999)。因此,我们考虑使用更真实的乳房解剖结构,包括皮肤,肌肉和悬韧带。乳腺组织被建模为neo-Hookean材料。乳房的物理正确建模需要无应力乳房配置的知识。这里,这种未变形的形状(即,没有任何残余应力)使用Eiben等人提出的预测-校正迭代方案(Ann of Biomed Eng 44:154- 173,201…
Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation
Radboud University Medical Center(拉德堡德大学医学中心);Netherlands Cancer Institute(荷兰癌症研究所);The University of Chicago(芝加哥大学);University of Pennsylvania(宾夕法尼亚大学);Lund University(隆德大学);Vall d’Hebron Institute of Oncology(巴尔德希伯伦肿瘤研究所);University of Barcelona(巴塞罗那大学);Dutch Expert Centre for Screening (LRCB)(荷兰筛查专家中心)
Voxel-Based Dose Prediction with Multi-Patient Atlas Selection for Automated Radiotherapy Treatment Planning
放射治疗计划过程的自动化是一个技术上具有挑战性的问题。大多数自动化方法集中于定制和推断剂量体积目标以用于计划优化。在这项工作中,我们概述了一个多病人的图集为基础的剂量预测方法,学习预测剂量每体素的一个新的病人直接从计算机断层成像(CT)计划扫描,而不需要指定任何目标。我们的方法学会自动为新患者选择最有效的图谱,然后将这些图谱中的剂量映射到新患者身上。我们扩展我们以前的工作,包括一个有条件的随机场的联合分布之前,匹配的互补目标的准确的空间分布的剂量分布,同时仍然坚持所需的剂量体积直方图的优化。然后,所得到的分布可以用于具有新的空间剂量目标的逆规划,或者用于为规范优化管道创建典型的剂量体积目标。我们调查了6个治疗部位(633例患者用于培训,113例患者用于测试),并评估了所有DVH的临床和预测剂量分布的平均绝对差(MAD)。与我们以前的方法相比,平均结果是有利的(1.91 vs 2.57)。将我们的方法与有和没有图谱选择进行比较,进一步验证了图谱选择平均改善了全乳腺中的剂量预测。(0.64 vs 1.59),前列腺(2.13对4.07),和直肠(1.46 vs 3.29),而在乳腺腔中不太重要(0.79 vs 0.92)和肺(1.33 vs 1.27),具有高度一致性和最小剂量成形。在CNS脑中,图谱选择具有潜在的影响力(3.65 vs 5.09),但选择理想的图谱是最具挑战性的。