arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2502.14524physics.med-ph
收藏

基于多笔形束激发的加速X射线荧光计算机断层扫描

Accelerated X-Ray Fluorescence Computed Tomography via Multi-Pencil-Beam Excitation

Ryder M. Schmidt, Daiki Hara, Jorge D. Vega, Marwan Abuhaija, Brett Bocian, Wendi Ma, Nesrin Dogan, Alan Pollack, Ge Wang, John C. Ford, Junwei Shi

AI总结:

针对台式XFCT成像时间长的问题,本研究结合蒙特卡罗模拟与3D打印开发多笔形束准直器,实验验证2束激发可2倍加速且不损失对比噪声比,模拟证实4束可实现至少4倍加速,有望将成像时间从小时级缩至分钟级。

摘要:

X射线荧光计算机断层扫描(XFCT)是X射线分子成像的一种形式,可为高原子序数金属纳米颗粒(MNP)提供精细的定量成像能力,这类纳米颗粒因在多功能诊疗一体化中的应用而被广泛研究。台式XFCT原型机因成本低廉、易于获取,通常采用搭配单笔形束(SPB)X射线激发的单像素探测器(SPD)。这种设计类似于第一代CT的几何结构,虽能实现可靠的检测灵敏度,但受限于成像时间过长的问题。采用同步多笔形束(MPB)激发是大幅缩短成像时间的一种极具前景的解决方案。本研究中,我们开发了一套可重复的工作流程,结合蒙特卡罗(MC)模拟与3D打印技术来设计Nbeam-MPB准直器,其中Nbeam为准直器产生的光束数量。作为初步测试,我们制作了一款2-MPB准直器,并在植入了含氯化金(H[AuCl4])琼脂糖微球的物理体模与小动物身上,评估了基于2-MPB的XFCT成像性能。结果表明,成像采集速度提升了2倍,且未降低对比噪声比(CNR)。我们进一步在MC计算XFCT系统上探究了Nbeam-MPB加速的概念,证实了采用4-MPB激发可实现至少4倍加速的可行性。结合额外的系统优化(如X射线束流优化),XFCT成像可进一步提速,将采集时间从数小时缩短至数分钟,满足常规MNP成像的需求。

英文摘要:

X-ray fluorescence computed tomography (XFCT), a form of X-ray molecular imaging, offers detailed quantitative imaging capabilities for high-Z metal nanoparticles (MNPs), which are widely studied for their applications in multifunctional theranostics. Due to its affordability and accessibility, the benchtop XFCT prototype typically employs a single-pixel detector (SPD) with single-pencil-beam (SPB) X-ray excitation. While this design (resembling the first-generation CT geometry) achieves reliable detection sensitivity, it is hindered by long imaging times. The use of simultaneous multiple-pencil-beam (MPB) excitation presents a promising solution to significantly reduce imaging times. In this study, we developed a repeatable workflow that combines Monte Carlo (MC) simulations and 3D printing to design Nbeam-MPB collimator, where Nbeam is the number of beams generated by the collimator. As an initial test, we fabricated a 2-MPB collimator and evaluated the performance of 2-MPB-based XFCT imaging on a physical phantom and small animals surgically implanted with agarose pellets containing gold chloride (H[AuCl4]). The results demonstrated a 2x acceleration in image acquisition without compromising the contrast-to-noise ratio (CNR). We further investigated the concept of Nbeam-MPB acceleration on the MC computational XFCT system, which confirmed the feasibility of achieving at least 4x acceleration with 4-MPB excitation. Combined with additional system optimization, such as X-ray beam flux optimization, XFCT imaging could be further accelerated, reducing acquisition time from hours to minutes and meeting the requirements for routine MNP imaging.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑