多摄像头系统自动校准:用于3D手术场景重建的有限重叠视场校准

Automatic Calibration of a Multi-Camera System with Limited Overlapping Fields of View for 3D Surgical Scene Reconstruction

Research in Orthopedic Computer Science(骨科计算机科学研究);University Hospital Balgrist(巴尔格斯特大学医院);University of Zurich(苏黎世大学);Computer Vision and Geometry(计算机视觉与几何);ETH Zurich(苏黎世联邦理工学院)

Tim Flückiger, Jonas Hein, Valery Fischer, Philipp Fürnstahl, Lilian Calvet

AI总结:

本研究提出了一种基于多尺度标记投影的自动校准方法,用于解决多摄像头系统在3D手术场景重建中的有限重叠视场问题,实现了高精度和鲁棒性。

摘要:

本研究旨在开发一种自动化且精确的外部摄像头校准方法,用于用于3D手术场景重建(3D-SSR)的多摄像头系统,以消除对操作员干预或专业知识的需求。该方法特别针对由显著的光学变焦水平和摄像头位置差异导致的有限重叠视场问题。我们贡献了一种基于多尺度标记(MSMs)投影的新型、快速且完全自动化的校准方法。MSMs由在不同尺度上投影的2D图案组成,确保在显著不同的视角和变焦水平下准确提取分布良好的点对应关系。通过在模拟手术室(mock-up OR)中捕获的合成和真实数据进行验证,与传统手动标记方法以及无标记校准方法进行比较。该方法在准确性上与手动、依赖操作员的校准方法相当,同时在显著的变焦水平差异条件下表现出更高的鲁棒性。此外,我们证明了最先进的结构从运动(SfM)流水线在3D-SSR设置中是无效的,即使在手术室地板上投影额外纹理时也是如此。使用安装在天花板上的入门级投影机被证明是传统依赖操作员的标记方法的有效替代方案,为完全自动化的3D-SSR铺平了道路。

英文摘要:

The purpose of this study is to develop an automated and accurate external camera calibration method for multi-camera systems used in 3D surgical scene reconstruction (3D-SSR), eliminating the need for operator intervention or specialized expertise. The method specifically addresses the problem of limited overlapping fields of view caused by significant variations in optical zoom levels and camera locations. We contribute a novel, fast, and fully automatic calibration method based on the projection of multi-scale markers (MSMs) using a ceiling-mounted projector. MSMs consist of 2D patterns projected at varying scales, ensuring accurate extraction of well distributed point correspondences across significantly different viewpoints and zoom levels. Validation is performed using both synthetic and real data captured in a mock-up OR, with comparisons to traditional manual marker-based methods as well as markerless calibration methods. The method achieves accuracy comparable to manual, operator-dependent calibration methods while exhibiting higher robustness under conditions of significant differences in zoom levels. Additionally, we show that state-of-the-art Structure-from-Motion (SfM) pipelines are ineffective in 3D-SSR settings, even when additional texture is projected onto the OR floor. The use of a ceiling-mounted entry-level projector proves to be an effective alternative to operator-dependent, traditional marker-based methods, paving the way for fully automated 3D-SSR.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑