arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2412.10031eess.IVcs.CV

FM2S:迈向零样本荧光显微镜图像去噪中的空间相关噪声建模

FM2S: Towards Spatially-Correlated Noise Modeling in Zero-Shot Fluorescence Microscopy Image Denoising

Harbin Institute of Technology(哈尔滨工业大学);The Hong Kong Polytechnic University(香港理工大学)

Jizhihui Liu, Qixun Teng, Qing Ma, Junjun Jiang

AI总结:

针对荧光显微镜图像去噪中空间相关混合噪声问题,提出零样本方法FM2S,通过噪声注入、两阶段学习和超轻量网络,实现高效去噪,性能优于现有方法。

摘要:

荧光显微镜图像(FMI)去噪面临严峻挑战,原因在于复合的混合泊松-高斯噪声具有强空间相关性,且在动态生物医学场景中获取配对的含噪/干净数据不切实际。虽然基于合成噪声(如高斯/泊松)训练的监督方法存在分布外泛化问题,但现有的自监督方法因过度简化的噪声假设和计算密集的深度架构,在真实FMI噪声下性能下降。本文提出荧光显微图到自身(FM2S),一种零样本去噪器,通过三项关键创新实现高效FMI去噪:1)噪声注入模块,通过自适应泊松-高斯合成确保训练数据充足,同时保留FMI噪声的空间相关性和全局统计特性,以增强模型泛化能力;2)两阶段渐进学习策略,首先通过预去噪目标恢复结构先验,然后通过噪声分布对齐细化高频细节;3)超轻量网络(3.5k参数),实现快速收敛,训练和推理速度比最先进方法快270倍。在FMI数据集上的大量实验证明了FM2S的优越性:其平均PSNR比CVF-SID高1.4dB,而参数仅为AP-BSN的0.1%。值得注意的是,FM2S在不同噪声水平下保持稳定性能,证明了其对具有多样传感器特性的显微镜平台的实用性。代码和数据集将发布。

英文摘要:

Fluorescence microscopy image (FMI) denoising faces critical challenges due to the compound mixed Poisson-Gaussian noise with strong spatial correlation and the impracticality of acquiring paired noisy/clean data in dynamic biomedical scenarios. While supervised methods trained on synthetic noise (e.g., Gaussian/Poisson) suffer from out-of-distribution generalization issues, existing self-supervised approaches degrade under real FMI noise due to oversimplified noise assumptions and computationally intensive deep architectures. In this paper, we propose Fluorescence Micrograph to Self (FM2S), a zero-shot denoiser that achieves efficient FMI denoising through three key innovations: 1) A noise injection module that ensures training data sufficiency through adaptive Poisson-Gaussian synthesis while preserving spatial correlation and global statistics of FMI noise for robust model generalization; 2) A two-stage progressive learning strategy that first recovers structural priors via pre-denoised targets then refines high-frequency details through noise distribution alignment; 3) An ultra-lightweight network (3.5k parameters) enabling rapid convergence with 270$\times$ faster training and inference than SOTAs. Extensive experiments across FMI datasets demonstrate FM2S's superiority: It outperforms CVF-SID by 1.4dB PSNR on average while requiring 0.1% parameters of AP-BSN. Notably, FM2S maintains stable performance across varying noise levels, proving its practicality for microscopy platforms with diverse sensor characteristics. Code and datasets will be released.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑