arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2409.07309astro-ph.IMastro-ph.EPastro-ph.GA
收藏

22/43/88/132 GHz频段的大地测量与天体测量甚长基线干涉测量实验

A Geodetic and Astrometric VLBI Experiment at 22/43/88/132 GHz

Shuangjing Xu, Taehyun Jung, Bo Zhang, Ming Hui Xu, Do-Young Byun, Xuan He, Nobuyuki Sakai, Oleg Titov, Fengchun Shu, Hyo-Ryoung Kim, Jungho Cho, Sung-Moon Yoo,… 展开作者

Shuangjing Xu, Taehyun Jung, Bo Zhang, Ming Hui Xu, Do-Young Byun, Xuan He, Nobuyuki Sakai, Oleg Titov, Fengchun Shu, Hyo-Ryoung Kim, Jungho Cho, Sung-Moon Yoo, Byung-Kyu Choi, Woo Kyoung Lee, Yan Sun, Xiaofeng Mai, Guangli Wang

AI总结:

本研究利用韩国甚长基线干涉网开展首次多频段大地测量模式VLBI实验,引入频率相位转移方法校准大气相位波动,提升了毫米波段弱源探测率与测量精度,验证了毫米波段用于高精度大地测量和天体测量的可行性。

摘要:

将大地测量与天体测量甚长基线干涉测量(VLBI)观测从传统厘米波段拓展至毫米波段具备诸多科学潜力与优势,但受毫米波段大气不透明度及湍流效应增强等多种因素影响,该方向此前被认为极具挑战性。本文展示了首次大地测量模式VLBI实验的结果,该实验利用韩国甚长基线干涉网(KVN)在22/43/88/132 GHz(K/Q/W/D波段)同时观测了82个射电源。我们将频率相位转移(FPT)方法引入大地测量VLBI数据分析,该方法通过转移低频段的相位解算结果来校准高频段的大气相位波动。在2分钟扫描时长下,FPT提升了绝大多数干涉条纹的信噪比(SNR),部分条纹信噪比提升超100%,进而提高了毫米波段弱源的探测率。此外,FPT降低了群延迟与延迟率中的系统误差:拟合后残差的加权均方根(WRMS)在W波段从25.0皮秒降至20.5皮秒,在D波段从39.3皮秒降至27.6皮秒。对于KVN基线,在K波段(WRMS=12.4皮秒)和Q波段(WRMS=11.8皮秒)校准大气相位波动时未观测到显著差异。本实验证明毫米波段可用于高精度的大地测量与天体测量应用。

英文摘要:

Extending geodetic and astrometric Very Long Baseline Interferometry (VLBI) observations from traditional centimeter wavebands to millimeter wavebands offers numerous scientific potentials and benefits. However, it was considered quite challenging due to various factors, including the increased effects of atmospheric opacity and turbulence at millimeter wavelengths. Here, we present the results of the first geodetic-mode VLBI experiment, simultaneously observing 82 sources at 22/43/88/132 GHz (K/Q/W/D bands) using the Korean VLBI Network (KVN). We introduced the frequency phase transfer (FPT) method to geodetic VLBI analysis, an approach for calibrating atmospheric phase fluctuations at higher frequencies by transferring phase solutions from lower frequencies. With a 2-minute scan, FPT improved the signal-to-noise ratio (SNR) of most fringes, some by over 100%, thereby enhancing the detection rate of weak sources at millimeter wavebands. Additionally, FPT reduced systematic errors in group delay and delay rate, with the weighted root-mean-squares (WRMS) of the post-fitting residuals decreasing from 25.0 ps to 20.5 ps at the W band and from 39.3 ps to 27.6 ps at the D band. There were no notable differences observed in calibrating atmospheric phase fluctuations at the K band (WRMS = 12.4 ps) and Q band (WRMS = 11.8 ps) with the KVN baselines. This experiment demonstrated that the millimeter waveband can be used for geodetic and astrometric applications with high precision.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑