arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2409.02030physics.ins-det
收藏

用于CEE谱仪的大型超导二极磁铁设计

Design of a large-scale superconducting dipole magnet for the CEE spectrometer

Yuquan Chen, Wei You, Jiaqi Lu, Yujin Tong, Luncai Zhou, Beimin Wu, Enming Mei, Wentian Feng, Xianjin Ou, Wei Wu, Qinggao Yao, Peng Yang, Yuhong Yu, Zhiyu Sun

AI总结:

本文针对CEE谱仪提出一种线圈主导型超导二极磁铁设计,采用跑道形截面导体、热铁轭、19股NbTi/Cu绞缆及主动失超保护与失超反冲相结合的方法,实现0.5 T中心场和5%均匀度。

摘要:

CSR外靶实验(CEE)是兰州重离子研究装置(HIRFL)正在建设的大型谱仪,用于研究高重子密度下核物质的相结构以及超饱和密度下核物质的状态方程。其关键部件之一是一台大接受度二极磁铁,中心场强为0.5 T,在长1 m、宽1.2 m、高0.9 m的孔径内均匀度为5%。探测器将安装在该孔径内。本文提出了一种超越常规方法的超导探测器磁铁创新设计。该磁铁设计为线圈主导型,导体离散布置在跑道形截面上以产生所需磁场。采用热铁轭来增强中心场并减小杂散场。磁铁总尺寸为长3.4 m、高2.7 m、宽4.3 m。线圈将采用由12根NbTi超导线和7根铜线组成的19股绞缆绕制。该缆线的铜超比为6.9。龙骨支撑作为线圈的主要结构支撑,以承受电磁力。线圈将通过三个外部氦容器中的液氦进行间接冷却。为确保磁铁在失超时得到可靠保护,采用了主动保护方法并结合失超反冲效应。本文主要介绍该谱仪磁铁的磁场、结构、失超保护和低温恒温器的详细设计。

英文摘要:

The CSR External-target Experiment (CEE) is a large-scale spectrometer under construction at the Heavy Ion Research Facility in Lanzhou (HIRFL) for studying the phase structure of nuclear matter at high baryon density and the equation of states of nuclear matter at supra-saturation densities. One of the key components is a large acceptance dipole magnet with a central field of 0.5 T and the homogeneity of 5% within a 1 m long, 1.2 m wide, and 0.9 m high aperture. Detectors will be installed within this aperture. An innovative design for the superconducting detector magnet is proposed that goes beyond the conventional approach. The magnet is designed as a coil-dominant type, with conductors discretized on a racetrack-shaped cross-section to generate the necessary fields. A warm iron yoke is used to enhance the central field and minimize the stray field. The magnet has overall dimensions of 3.4 meters in length, 2.7 meters in height, and 4.3 meters in width. The coils will be wound using a 19-strand rope cable comprised of 12 NbTi superconducting wires and 7 copper wires. The ratio of copper to superconductor of the cable is 6.9. The keel supports serve as the primary structural support for the coils to withstand the electromagnetic force. The coils will be indirectly cooled by liquid helium within three external helium vessels. To ensure reliable protection of the magnet during a quench, an active protection method combined with quench-back effect is employed. In this paper, we mainly present the detailed design of the magnetic field, structure, quench protection and cryostat for the spectrometer magnet.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑