Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study
M. Dadgar, S. Parzych, F. Tayefi Ardebili, J. Baran, N. Chug, C. Curceanu, E. Czerwinski, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon… 展开作者
M. Dadgar, S. Parzych, F. Tayefi Ardebili, J. Baran, N. Chug, C. Curceanu, E. Czerwinski, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Niedzwiecki, D. Panek, E. Perez del Rio, L. Raczynski, S. Sharma, Shivani, R. Y. Shopa, M. Skurzok, K. Tayefi Ardebili, S. Vandenberghe, W. Wislicki, E. Stepien, P. Moskal
The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.
A tissue-informed deep learning-based method for positron range correction in preclinical 68Ga PET imaging
University Complutense of Madrid (UCM)(马德里康普顿斯大学);Instituto de Investigación Sanitaria, Hospital Clínico San Carlos (IdISSC)(圣卡洛斯临床医院卫生研究所 (IdISSC));Memorial Sloan Kettering Cancer Center(纪念斯隆-凯特琳癌症中心);Weill Cornell Graduate School(韦尔康奈尔研究生院)
Quantitative In Vivo Cherenkov Luminescence Imaging and Dosimetry of Yttrium-86-NM600
University of Wisconsin School of Medicine and Public Health, University of Wisconsin–Madison(威斯康星大学麦迪逊分校医学院与公共卫生学院);Thayer School of Engineering at Dartmouth(达特茅斯学院塔耶尔工程学院)
Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging
Université de Sherbrooke(谢布鲁克大学);Interdisciplinary Institute for Technological Innovation(跨学科技术创新研究所);Sherbrooke Molecular Imaging Center of CRCHUS(CRCHUS谢布鲁克分子成像中心);Institut Fresnel(弗雷内尔研究所);Aix Marseille Univ(艾克斯-马赛大学);Centrale Med(中央医学院);Imaging Research & Technology (IR&T) Inc.(成像研究与技术公司)
Analytic Model of Trans-axial Sensitivity in Cylindrical PET Systems Based on Solid Angle
School of Software Engineering, Huazhong University of Science and Technology(华中科技大学软件学院);RAYSOLUTION healthcare Co., ltd(锐思健康科技有限公司);School of Information Science and Technology, University of Science and Technology of China(中国科学技术大学信息科学与技术学院);Department of Biomedical Engineering, Huazhong University of Science and Technology(华中科技大学生物医学工程系)
A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer
前列腺癌是男性最常见的疾病,也是癌症死亡的第二大原因。用于癌症诊断的通用大型成像仪器具有灵敏度、空间分辨率和对比度,不足以完成对诸如前列腺的小器官的细节进行成像的任务。此外,多模态成像可以发挥重要作用,合并来自同步PET和MRI的解剖和功能细节。事实上,多参数PET/MRI被证明可以提高诊断,但它有太多的假阳性。为了解决当前技术的上述限制,我们已经提出,建立和测试,由于TOPEM项目由意大利国家核物理研究所资助的直肠内PET-TOF/MRI探头的原型。在应用的放大PET几何结构中,性能由放置在更靠近源的高分辨率探测器主导。所选几何结构中的预期空间分辨率约为1.5 mm FWHM,效率为常规PET扫描仪的2倍。在我们的实验研究中,我们已经获得了约320 ps的FWHM的时间分辨率,并在同一时间的相互作用深度(DOI)的分辨率为1毫米以下。测试还表明,相互不利的PET-MR效应是最小的。此外,还设计、制造和测试了匹配的直肠内射频线圈。在接下来计划的研究中,我们希望受益于闪烁体晶体表面处理、SiPM技术和相关电子学的进一步进展,将使我们能够显著提高TOF分辨率
CRYSP: a Total-Body PET based on cryogenic cesium iodide crystals
Donostia International Physics Center(多诺斯蒂亚国际物理中心);Ikerbasque (Basque Foundation for Science)(伊克拉巴斯基(巴斯克科学基金会));Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València(分子成像仪器研究所(I3M),CSIC-瓦伦西亚理工大学联合中心);Universidad del País Vasco (UPV/EHU)(巴斯克大学);Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València(粒子物理研究所(IFIC),CSIC与瓦伦西亚大学)