arXiv 2307.08335physics.med-ph

PET中数据驱动的改进采样

Data-driven Improved Sampling in PET

Pablo Galve, Alejandro Lopez-Montes, Jose M Udias, Stephen C Moore, Joaquin L Herraiz

AI总结:

本文提出一种数据驱动的PET插值采样方法,通过重建后估计虚拟subLOR计数并进行两到三次超级迭代,突破探测器几何采样限制,显著改善空间分辨率。

摘要:

正电子发射断层扫描(PET)扫描仪的设计通常旨在在灵敏度、分辨率、视野大小和成本之间取得最佳折中。因此,很难在不影响其他一些重要参数的情况下,通过硬件改进来提高PET扫描仪的分辨率。诸如有序子集期望最大化(OSEM)算法之类的迭代图像重建方法,能够通过使用包含所有相关物理效应的真实系统响应矩阵来获得一定的分辨率恢复。尽管如此,这种分辨率恢复通常受到由探测器几何结构决定的投影空间采样减少的限制。本工作的目标是通过利用数据驱动的插值数据增加采样,将分辨率提高到超越探测器尺寸的限制。在完成一次完整图像重建后,对每条虚拟子响应线(subLOR)中的计数进行最大似然估计,同时保留初始数据集的统计特性。新的估计被用于下一次完整重建。该方法通常需要两到三次这样的完整重建(超级迭代)。我们针对SMI制造的Argus和Super Argus临床前PET扫描仪,通过模拟和真实采集对其进行了评估,并考虑了不同类型的增加采样。针对标准OSEM和连续超级迭代,对每次迭代中恢复和分辨率随噪声的演变进行的定量测量显示出良好结果。该过程能够显著降低大晶体中相互作用深度的影响,并改善空间分辨率。所提出的方法相当通用,可应用于其他扫描仪和配置。

英文摘要:

Positron Emission Tomography (PET) scanners are usually designed with the goal to obtain the best compromise between sensitivity, resolution, field-of-view size, and cost. Therefore, it is difficult to improve the resolution of a PET scanner with hardware modifications, without affecting some of the other important parameters. Iterative image reconstruction methods such as the ordered subsets expectation maximization (OSEM) algorithm are able to obtain some resolution recovery by using a realistic system response matrix that includes all the relevant physical effects. Nevertheless, this resolution recovery is often limited by reduced sampling in the projection space, determined by the geometry of the detector. The goal of this work is to improve the resolution beyond the detector size limit by increasing the sampling with data-driven interpolated data. A maximum-likelihood estimation of the counts in each virtual sub-line-of-response (subLOR) is obtained after a complete image reconstruction, conserving the statistics of the initial data set. The new estimation is used for the next complete reconstruction. The method typically requires two or three of these full reconstructions (superiterations). We have evaluated it with simulations and real acquisitions for the Argus and Super Argus preclinical PET scanners manufactured by SMI, considering different types of increased sampling. Quantitative measurements of recovery and resolution evolution against noise per iteration for the standard OSEM and successive superiterations show promising results. The procedure is able to reduce significantly the impact of depth-of-interaction in large crystals, and to improve the spatial resolution. The proposed method is quite general and it can be applied to other scanners and configurations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑