Single channel PICOSEC Micromegas detector with improved time resolution
A. Utrobicic, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, G. Fanourakis, D. Fiorina, K. J. Floet… 展开作者
A. Utrobicic, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, M. Lupberger, I. Maniatis, J. McKisson, Y. Meng, H. Muller, E. Oliveri, G. Orlandini, A. Pandey, T. Papaevangelou, M. Pomorski, L. Ropelewski, D. Sampsonidis, L. Scharenberg, T. Schneider, L. Sohl, M. van Stenis, Y. Tsipolitis, S. E. Tzamarias, I. Vai, R. Veenhof, P. Vitulo, X. Wang, S. White, W. Xi, Z. Zhang, Y. Zhou
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
CERN(欧洲核子研究组织);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊国家加速器装置);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);University of Bonn(波恩大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁杰尔·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Signal Processing and Machine Learning Algorithms for Precise Timing with PICOSEC Micromegas Detectors
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Centre for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);University of Hamburg(汉堡大学)
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);CERN(欧洲核子研究组织);Stony Brook University(石溪大学);NCSR Demokritos(德墨忒勒斯国家科学研究中心);University of Bonn(波恩大学);LIP(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊实验室);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁德·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
European Organization for Nuclear Research (CERN)(欧洲核子研究组织);University of Turin(都灵大学);Middle East Technical University(中东技术大学);Technion - Israel Institute of Technology(以色列理工学院);IRFU, CEA, Université Paris-Saclay(巴黎萨克雷大学CEA IRFU);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Weizmann Institute of Science(魏茨曼科学研究所);Università di Pavia(帕维亚大学);INFN Sezione di Pavia(意大利国家核物理研究院帕维亚分部);Stony Brook University(石溪大学)
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Ruđer Bošković Institute(鲁杰尔博什科维奇研究所);University of Zagreb, Faculty of Electrical Engineering and Computing(萨格勒布大学电气工程和计算学院);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas(粒子物理实验与仪器实验室);Helsinki Institute of Physics, University of Helsinki(赫尔辛基大学赫尔辛基物理研究所);Jefferson Lab(杰斐逊国家加速器设施);University of Science and Technology of China(中国科学技术大学);Helmholtz-Institut für Strahlen- und Kernphysik, University of Bonn(波恩大学赫尔姆霍茨射线与核物理研究所);Physikalisches Institut, University of Bonn(波恩大学物理研究所);CEA-LIST(法国原子能和替代能源委员会列表研究所);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);National Technical University of Athens(雅典国立技术大学)
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);CERN(欧洲核子研究中心);Stony Brook University(石溪大学);NCSR Demokritos(德墨忒尔国家科学研究中心);University of Bonn(波恩大学);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理实验与仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰弗逊实验室);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);CEA-List, Diamond Sensors Laboratory, CEA-Saclay(CEA-列表,钻石传感器实验室,CEA-萨克雷);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁德·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Thomas Jefferson National Accelerator Facility(托马斯·杰斐逊国家加速器设施);IRFU, CEA, Université Paris-Saclay(IRFU, 法国原子能和替代能源委员会, 巴黎萨克雷大学);Department of Physics, Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学物理系);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Department for Medical Physics, Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学医学物理系);European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Dipartimento di Fisica, Università di Pavia(帕维亚大学物理系);INFN Sezione di Pavia(意大利国家核物理研究所帕维亚分部);Department of Physics and Astronomy, Stony Brook University(石溪大学物理与天文学系);Institute of Nuclear and Particle Physics, NCSR Demokritos(国家科学研究中心德谟克利特研究所核与粒子物理研究所)
A low background Micromegas detector for the CAST experiment
在欧洲核子研究中心的CAST实验第一阶段(2002-2004年),一个低本底Micromegas探测器一直在运行,用于搜索太阳轴子。由于其良好的空间和能量分辨率以及在探测器构造中使用的低放射性材料,该探测器有效运行并实现了非常低水平的背景抑制($5\times 10^{-5}$计数keV $^{-1}$ cm $^{-2}$ s $^{-1}$)。在实验的第二阶段(2005-2007年),将对探测器进行升级,增加一个屏蔽装置并包括聚焦光学系统。这些改进应允许优于两个数量级的背景抑制。
Detection of collinear high energetic di-photon signatures with Micromegas Detectors
近年来,对弱相互作用的、与光子耦合的轻粒子的研究受到了极大的关注。当这些粒子以高能量产生时,它们在衰变后会产生两个几乎共线的光子,因此可以被电磁量热计系统检测到。寻找这些高能弱粒子的典型主导背景是单个高能光子,它们在标准量热计系统中留下类似的特征。一个有希望的方法来分离信号从背景事件是采用一个专门的预簇射探测器在前面的量热计,可以区分单和双光子签名。在这项工作中,我们提出了这种探测器的概念设计,它能够从两个共线光子信号中分离出一个,对于两个相距0.1mm至2mm的光子,效率在20%至80%之间,能量高于300 GeV,背景抑制率超过90%。我们的预簇射探测器设计具有10cm x 10cm的有效表面积,深度为230mm,基于Micromegas探测器,因此提供了一种具有成本效益的解决方案。