The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric pressure. At higher energies (MeV scale), these measurements are more complicated due to the difficulty in confining the events in the chamber, although there is no fundamental reason why resolutions of 1% FWHM or below could not be reached. There is much motivation to demonstrate experimentally this fact in Xe mixtures due to the possible application of Micromegas readouts to the Double Beta Decay search of $^{136}$Xe, or in other experiments needing calorimetry and topology in the same detector. In this paper, we report on systematic measurements of energy resolution with state-of-the-art Micromegas using a 5.5 MeV alpha source in high pressure Ar/isobutane mixtures. Values as low as 1.8% FWHM have been obtained, with possible evidence that better resolutions are achievable. Similar measurements in Xe, of which a preliminary result is also shown here, are under progress.
CAST microbulk micromegas in the Canfranc Underground Laboratory
在CAST实验的最后一次数据采集活动中,微兆气体探测器已经实现了$\approx 5 \times 10^{-6}$ keV $^{-1}$ cm $^{-2}$ s $^{-1}$在2和9 keV之间的背景水平。这种性能是可能的,这要归功于微批量技术的引入,屏蔽的实施和歧视算法的发展。它激发了新的研究,以更深入地了解CAST探测器的背景。其中一条工作线包括建造一个微型气体探测器在CAST中使用的装置的复制品,并将其安装在Canfranc地下实验室。由于地下和地面探测器性能之间的比较,屏蔽升级等,对探测器背景的不同贡献进行了评估。特别地,已经获得了检测器的本征背景的上限$< 2 \times 10^{-7}$ keV $^{-1}$ cm $^{-2}$ s $^{-1}$。这项工作意味着在地下实验室中对最新的micromegas技术的潜力进行了首次评估,这是最适合稀有事件探测的环境。
The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136
在寻找$^{136}$氘的无中微子双β衰变过程中,高压氙时间投影室(HPXe-TPC)与液体氙TPC相比具有两个优势:更好的能量分辨率和拓扑特征,这可以提供额外的背景事件区分。PandaX-III实验最近提出了一个基于Micromegas读出平面的200 kg HPXe-TPC,位于中国锦屏地下实验室。它的探测概念基于T-REX项目中获得的两个结果:Micromegas读数可以在极低的放射性水平下构建;在现实实验条件下在10 bar的氙-三甲胺中操作已证明在感兴趣区域的能量分辨率为3% FWHM。在这项工作中,两个歧视的方法被施加到一个通用的200公斤HPXe-TPC的模拟信号和背景数据,基于两个著名的图论算法:识别的连接和搜索的最长路径。拒绝因子大于100的小像素尺寸和40%的信号效率。此外,一个新的可观察的(斑点电荷密度)拒绝更好的表面污染,这使得触发信号($T_0$)的使用在这个实验中不是必要的。
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
我们报告的性能10大气压氙/三甲胺时间投影室(TPC)的X射线(30千电子伏)和γ射线(0.511-1.275兆电子伏)的检测结合相关电子的准确跟踪。当在如此高的压力和1%的混合物中操作时,除了形成方便的潘宁-荧光混合物之外,三甲胺(TMA)赋予氙极低的电子扩散(1.3 ± 0.13 mm-σ(纵向),0.8 ± 0.15 mm-σ(横向),沿1 m漂移)。TPC在其有效体积中容纳1.1 kg气体,在电荷放大模式下连续运行100个生存日。读出是通过最近推出的microbulk Micromegas技术和AFTER芯片进行的,为大约10 cm/MeV长的电子径迹提供了8 mm x 8 mm x 1.2mm的3D体素化。这项工作是作为NEXT合作的研发计划的一部分开发的,用于未来的探测器升级,以寻找136 kB中的0 bbnu衰变,特别是那些基于新型气体混合物的探测器。因此,我们最终专注于重建的MeV电子轨道的量热和拓扑性质。
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Micromegas探测器由于具有良好的空间和时间分辨能力,是稀有事件搜索实验的良好候选者。最近的X射线的背景水平,这些探测器在CAST实验中实现了进一步的研究,在测量的背景水平的性质。特别是,不同的屏蔽配置已在Canfranc地下实验室进行了测试,使用微散装型探测器,这是以前运行在CAST实验。地下的第一个结果表明,这种技术是由低辐射材料制成的,在适当的屏蔽下,能够达到高达$2 \times 10^{-7}$ keV $^{-1}$ s $^{-1}$ cm $^{-2}$的背景水平。此外,Geant 4模拟补充了实验背景测量,可以了解背景的起源,并优化未来的屏蔽设置。