A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
X. Wang, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, D. Fiorina, K. J. Floethner,… 展开作者
X. Wang, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, I. Maniatis, J. McKisson, Y. Meng, H. Muller, E. Oliveri, G. Orlandini, A. Pandey, T. Papaevangelou, M. Pomorski, L. Ropelewski, D. Sampsonidis, L. Scharenberg, T. Schneider, L. Shang, M. Shao, L. Sohl, M. van Stenis, Y. Tsipolitis, S. E. Tzamarias, A. Utrobicic, I. Vai, R. Veenhof, P. Vitulo, S. White, W. Xi, Z. Zhang, Y. Zhou
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
European Organization for Nuclear Research (CERN)(欧洲核子研究组织);University of Turin(都灵大学);Middle East Technical University(中东技术大学);Technion - Israel Institute of Technology(以色列理工学院);IRFU, CEA, Université Paris-Saclay(巴黎萨克雷大学CEA IRFU);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Weizmann Institute of Science(魏茨曼科学研究所);Università di Pavia(帕维亚大学);INFN Sezione di Pavia(意大利国家核物理研究院帕维亚分部);Stony Brook University(石溪大学)
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
CERN(欧洲核子研究组织);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊国家加速器装置);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);University of Bonn(波恩大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁杰尔·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Signal Processing and Machine Learning Algorithms for Precise Timing with PICOSEC Micromegas Detectors
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Centre for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);University of Hamburg(汉堡大学)
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);CERN(欧洲核子研究组织);Stony Brook University(石溪大学);NCSR Demokritos(德墨忒勒斯国家科学研究中心);University of Bonn(波恩大学);LIP(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊实验室);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁德·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Ruđer Bošković Institute(鲁杰尔博什科维奇研究所);University of Zagreb, Faculty of Electrical Engineering and Computing(萨格勒布大学电气工程和计算学院);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas(粒子物理实验与仪器实验室);Helsinki Institute of Physics, University of Helsinki(赫尔辛基大学赫尔辛基物理研究所);Jefferson Lab(杰斐逊国家加速器设施);University of Science and Technology of China(中国科学技术大学);Helmholtz-Institut für Strahlen- und Kernphysik, University of Bonn(波恩大学赫尔姆霍茨射线与核物理研究所);Physikalisches Institut, University of Bonn(波恩大学物理研究所);CEA-LIST(法国原子能和替代能源委员会列表研究所);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);National Technical University of Athens(雅典国立技术大学)
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);CERN(欧洲核子研究中心);Stony Brook University(石溪大学);NCSR Demokritos(德墨忒尔国家科学研究中心);University of Bonn(波恩大学);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理实验与仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰弗逊实验室);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);CEA-List, Diamond Sensors Laboratory, CEA-Saclay(CEA-列表,钻石传感器实验室,CEA-萨克雷);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁德·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Thomas Jefferson National Accelerator Facility(托马斯·杰斐逊国家加速器设施);IRFU, CEA, Université Paris-Saclay(IRFU, 法国原子能和替代能源委员会, 巴黎萨克雷大学);Department of Physics, Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学物理系);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Department for Medical Physics, Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学医学物理系);European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Dipartimento di Fisica, Università di Pavia(帕维亚大学物理系);INFN Sezione di Pavia(意大利国家核物理研究所帕维亚分部);Department of Physics and Astronomy, Stony Brook University(石溪大学物理与天文学系);Institute of Nuclear and Particle Physics, NCSR Demokritos(国家科学研究中心德谟克利特研究所核与粒子物理研究所)
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area
European Organization for Nuclear Research (CERN)(欧洲核子研究中心);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Institut de Recherche sur les lois Fondamentales de l’Univers (IRFU, CEA)(基础定律宇宙研究所);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学)