arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2402.12892hep-exhep-ph
收藏

利用CAPP主轴子实验在1 GHz以上对轴子暗物质的大范围搜寻

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

Saebyeok Ahn, JinMyeong Kim, Boris I. Ivanov, Ohjoon Kwon, HeeSu Byun, Arjan F. van Loo, SeongTae Par, Junu Jeong, Soohyung Lee, Jinsu Kim, Çağlar Kutlu, Andrew… 展开作者

Saebyeok Ahn, JinMyeong Kim, Boris I. Ivanov, Ohjoon Kwon, HeeSu Byun, Arjan F. van Loo, SeongTae Par, Junu Jeong, Soohyung Lee, Jinsu Kim, Çağlar Kutlu, Andrew K. Yi, Yasunobu Nakamura, Seonjeong Oh, Danho Ahn, SungJae Bae, Hyoungsoon Choi, Jihoon Choi, Yonuk Chong, Woohyun Chung, Violeta Gkika, Jihn E. Kim, Younggeun Kim, Byeong Rok Ko, Lino Miceli, Doyu Lee, Jiwon Lee, Ki Woong Lee, MyeongJae Lee, Andrei Matlashov, Pallavi Parashar, Taehyeon Seong, Yun Chang Shin, Sergey V. Uchaikin, SungWoo Youn, Yannis K. Semertzidis

AI总结:

CAPP利用12 T超导磁体、37升超轻铜腔和稀释制冷机等创新技术,在1.025-1.185 GHz范围对轴子暗物质进行高灵敏度搜寻,获得了该频段迄今最严格的轴子-光子耦合排除极限。

摘要:

我们报告了在轴子与精密物理研究中心(CAPP)进行的1 GHz以上轴子暗物质的高灵敏度大范围搜寻。利用轴子与光子之间的耦合进行的腔共振搜寻,探索了1.025 GHz(4.24 μeV)至1.185 GHz(4.91 μeV)的频率(质量)范围。我们在该领域引入了一系列创新,展示了优化轴子haloscope所有相关参数的实用方法,扩展了现有可用技术。CAPP 12 T磁体孔径为320 mm,由Nb3Sn和NbTi超导体制成,围绕一个37升超轻铜腔,预计每秒可将DFSZ轴子转换为约10^2个微波光子。一台强大的稀释制冷机能够将核心系统保持在40 mK以下,结合量子噪声极限的读出电子学,实现了约200 mK或更低的总系统噪声,这对应于轴子带宽内约每秒4×10^3个光子的背景。所有这些改进的结合提供了前所未有的搜寻性能,在该频率范围内对轴子-光子耦合施加了迄今为止最严格的排除极限。这些结果还表明,该实验能力适用于在1 GHz以上对轴子暗物质进行高灵敏度搜寻。

英文摘要:

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑