arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2312.09459eess.SP
收藏

一种基于一维生成对抗网络的新型框架,利用恢复的腕部光电容积脉搏波信号进行心房颤动检测

A Novel 1D Generative Adversarial Network-based Framework for Atrial Fibrillation Detection using Restored Wrist Photoplethysmography Signals

Faizul Rakib Sayem, Mosabber Uddin Ahmed, Saadia Binte Alam, Sakib Mahmud, Md. Mamun Sheikh, Abdulrahman Alqahtani, Md Ahasan Atick Faisal, Muhammad E. H. Chowdhury

AI总结:

本研究提出基于一维CycleGAN恢复腕部PPG信号并结合Self-AFNet模型检测心房颤动,在21,278个片段上验证,恢复后准确率显著提升,与ECG检测性能相当,有助于降低中风风险。

摘要:

心房颤动(AF)会增加中风风险。心电图(ECG)用于检测心房颤动,而光电容积脉搏波(PPG)使用简单且适合长期监测。我们开发了一种从智能手表腕部PPG信号中检测心房颤动的新方法。据我们所知,这是首次采用一维CycleGAN(循环生成对抗网络)来重建一维腕部PPG信号的研究,因为腕部PPG信号由于运动伪影和采集部位的限制而质量非常差。我们提出的方法在包含21,278个10秒长腕部PPG片段的数据集上进行了验证。该数据集被分成两半,进行了两次实验。一半用于训练,另一半用于测试,反之亦然。我们的分类模型(Self-AFNet)结合一维CycleGAN进行信号恢复,在两个分割上的准确率分别达到96.41%和97.09%。与未恢复的PPG相比,恢复后的信号在准确率上有显著提升(测试分割分别提升2.94%和5.08%)。还使用与匹配PPG信号对应的ECG信号进行了心房颤动检测任务,以评估使用重建的基于PPG的心房颤动分类的有效性。Self-AFNet在使用两个ECG分割时分别达到了98.07%和98.97%的准确率,这与使用重建的PPG片段进行心房颤动检测的性能相当。这项研究表明,从可穿戴设备获取的重建腕部PPG信号可用于可靠地检测心房颤动,这有助于显著降低中风风险。

英文摘要:

Atrial fibrillation (AF) increases the risk of stroke. Electrocardiogram (ECG) is used for AF detection, while photoplethysmography (PPG) is simple to use and appropriate for long-term monitoring. We have developed a novel approach to detect AF from smartwatch-based wrist PPG signals. To the best of our knowledge, this is the first study to employ 1D CycleGAN for the reconstruction of 1D wrist PPG signals, since the quality of wrist PPG signals is very poor due to motion artifacts and acquisition site limitations. Our proposed approach is validated on a dataset of 21,278 10s long wrist PPG segments. The dataset was divided into two halves and two experiments were conducted. One half was used for training and the other half for testing and vice versa. Our classification model (Self-AFNet) with 1D-CycleGAN for restoration achieves an accuracy of 96.41% and 97.09% for both splits, respectively. There is a noteworthy improvement in accuracy (2.94% and 5.08% for test splits, respectively) for restored signals as compared to unrestored PPG. AF detection task was also performed using ECG signals with the matched PPG signals to assess the validity of employing reconstructed PPG-based AF classification. Self-AFNet managed to achieve an accuracy of 98.07% and 98.97%, respectively using two ECG splits which is comparable to the performance of AF detection utilizing reconstructed PPG segments. This study reflects that reconstructed wrist PPG signals acquired from wearable devices can be used for reliable detection of atrial fibrillation, which can significantly help in the reduction of the risk of stroke.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑