arXiv 2307.02806eess.SP

一种基于奇异值并使用高分辨率电图和多导联心电图检测心房颤动的标记方法

A Singular-value-based Marker for the Detection of Atrial Fibrillation Using High-resolution Electrograms and Multi-lead ECG

Hanie Moghaddasi, Richard C. Hendriks, Borbala Hunyadi, Paul Knops, Mathijs S van Schie, Natasja M. S. de Groot, Alle-Jan van der Veen

AI总结:

本文提出一种基于心外膜测量矩阵奇异值的非参数方法,通过动作电位形态的空间变化检测房颤,并验证其在多导联心电图中的有效性。

摘要:

心房颤动(AF)的严重程度可通过术中心外膜测量(高分辨率电图)进行评估,所用指标包括传导阻滞(CB)和连续传导延迟与阻滞(cCDCB)。这些特征捕捉了传导速度和波前传播的差异。然而,在患者处于窦性心律时,这些特征无法清楚地区分不同房颤程度的患者,因此需要补充特征。在本工作中,我们关注动作电位的形态,并推导用于检测心房电位波形变化的特征。方法:我们表明,单次心搏期间心房电位形态的空间变化可以通过心外膜测量矩阵奇异值的变化来描述。该方法是非参数的,且几乎不需要预处理。相应的奇异值图可指示存在碎裂和阻滞的区域。此外,我们设计了一项实验,同时测量电图(EGMs)和多导联心电图。结果:采集到的数据表明,房颤期间心搏的归一化奇异值高于窦性心律期间,并且如果电极放置在有利位置,这种差异在(无创)心电图数据中比在电图数据中更为明显。结论:总体而言,基于奇异值的特征是一种用于检测和评估房颤的有用指标。意义:所提出的方法可能有助于在不估计局部激活时间的情况下识别组织中的电病理区域。

英文摘要:

The severity of atrial fibrillation (AF) can be assessed from intra-operative epicardial measurements (high-resolution electrograms), using metrics such as conduction block (CB) and continuous conduction delay and block (cCDCB). These features capture differences in conduction velocity and wavefront propagation. However, they do not clearly differentiate patients with various degrees of AF while they are in sinus rhythm, and complementary features are needed. In this work, we focus on the morphology of the action potentials, and derive features to detect variations in the atrial potential waveforms. Methods: We show that the spatial variation of atrial potential morphology during a single beat may be described by changes in the singular values of the epicardial measurement matrix. The method is non-parametric and requires little preprocessing. A corresponding singular value map points at areas subject to fractionation and block. Further, we developed an experiment where we simultaneously measure electrograms (EGMs) and a multi-lead ECG. Results: The captured data showed that the normalized singular values of the heartbeats during AF are higher than during SR, and that this difference is more pronounced for the (non-invasive) ECG data than for the EGM data, if the electrodes are positioned at favorable locations. Conclusion: Overall, the singular value-based features are a useful indicator to detect and evaluate AF. Significance: The proposed method might be beneficial for identifying electropathological regions in the tissue without estimating the local activation time.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑