arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2008.02228eess.SP
收藏

基于深度递归神经网络的远程心房颤动负荷估计

Remote atrial fibrillation burden estimation using deep recurrent neural network

Armand Chocron, Julien Oster, Shany Biton, Mandel Franck, Meyer Elbaz, Yehoshua Y. Zeevi, Joachim Behar

摘要:

房颤负荷(AFB)定义为在足够长的监测期内房颤(AF)持续时间的百分比。最近的研究表明,与二元诊断相比,使用AFB可获得额外的预后价值。我们首次评估了使用深度递归神经网络(DRNN)方法在长期连续记录中估计AFB的能力。研究方法:这些模型是在p= 2,891例患者的大型数据库中开发和评估的,在弗吉尼亚大学心脏站获得的连续心电图(ECG)记录总计t= 68,800小时。具体而言,从单个便携式ECG通道获得24小时逐搏时间序列。该网络表示为ArNet,以梯度增强(XGB)模型为基准,在21个特征上进行训练,包括样本熵系数(CosEn)和AFEvidence。数据分为训练集和测试集,而患者根据AF的存在和严重程度进行分层。ArNet和XGB的泛化也在独立测试PhysioNet LTAF数据库上进行了评估。结果如下:对于AF个体,测试集上的绝对AF负荷估计误差|E_AF|、中位数和四分位数对于ArNet为1.2(0.1-6.7),对于XGB为3.1(0.0-11.7)。LTAF的泛化结果与ArNet的2.6(1.1-14.7)和XGB的3.6(1.0-16.7)的E_AF一致。结论:本研究证明了利用DRNN的最新进展从24小时心跳间期时间序列估计AFB的可行性。意义:新的数据驱动方法可以实现强大的AF远程诊断和表型分析。

英文摘要:

The atrial fibrillation burden (AFB) is defined as the percentage of time spend in atrial fibrillation (AF) over a long enough monitoring period. Recent research has demonstrated the added prognosis value that becomes available by using the AFB as compared with the binary diagnosis. We evaluate, for the first time, the ability to estimate the AFB over long-term continuous recordings, using a deep recurrent neutral network (DRNN) approach. Methods: The models were developed and evaluated on a large database of p=2,891 patients, totaling t=68,800 hours of continuous electrocardiography (ECG) recordings acquired at the University of Virginia heart station. Specifically, 24h beat-to-beat time series were obtained from a single portable ECG channel. The network, denoted ArNet, was benchmarked against a gradient boosting (XGB) model, trained on 21 features including the coefficient of sample entropy (CosEn) and AFEvidence. Data were divided into training and test sets, while patients were stratified by the presence and severity of AF. The generalizations of ArNet and XGB were also evaluated on the independent test PhysioNet LTAF database. Results: the absolute AF burden estimation error |E_AF|, median and interquartile, on the test set, was 1.2 (0.1-6.7) for ArNet and 3.1 (0.0-11.7) for XGB for AF individuals. Generalization results on LTAF were consistent with E_AF of 2.6 (1.1-14.7) for ArNet and 3.6 (1.0-16.7) for XGB. Conclusion: This research demonstrates the feasibility of AFB estimation from 24h beat-to-beat interval time series utilizing recent advances in DRNN. Significance: The novel data-driven approach enables robust remote diagnosis and phenotyping of AF.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑