arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2308.04903eess.IVphysics.med-ph

低场强下胎儿体部定量T2* MRI与分割的自动化流程

An automated pipeline for quantitative T2* fetal body MRI and segmentation at low field

Kelly Payette, Alena Uus, Jordina Aviles Verdera, Carla Avena Zampieri, Megan Hall, Lisa Story, Maria Deprez, Mary A. Rutherford, Joseph V. Hajnal, Sebastien Ou… 展开作者

Kelly Payette, Alena Uus, Jordina Aviles Verdera, Carla Avena Zampieri, Megan Hall, Lisa Story, Maria Deprez, Mary A. Rutherford, Joseph V. Hajnal, Sebastien Ourselin, Raphael Tomi-Tricot, Jana Hutter

AI总结:

本文提出一种低场强胎儿体部定量T2* MRI半自动流程,结合可变形切片到体积重建和半监督神经网络分割十个器官,并验证T2*值与胎龄的相关性及对运动伪影的鲁棒性。

摘要:

低场强胎儿磁共振成像正成为围产期健康领域一个令人振奋的方向。临床低场(0.55T)扫描仪由于减少了磁化率伪影、提高了T2*值,并具有更宽的孔径(为日益增多的肥胖孕妇群体拓宽了检查通道),因而对胎儿成像具有优势。然而,缺乏标准的自动化图像处理工具(如分割和重建)阻碍了其更广泛的临床应用。在本研究中,我们引入了一个在低场强下使用定量MRI对胎儿体部进行成像的半自动流程,能够对所有主要胎儿体部器官进行快速且详细的定量T2*弛豫分析。我们采集了胎儿体部的多回波动态序列,并利用可变形切片到体积重建将其重建为单个高分辨率体积,同时生成结构性和定量T2*三维体积。我们创建了一个采用半监督方法训练的神经网络,用于将这些胎儿体部三维体积自动分割为十个不同器官(10个器官中有8个的Dice值大于0.74)。T2*值显示与胎龄在肺、肝和肾实质中存在强相关性(R^2>0.5)。该流程已成功应用于广泛的胎龄范围(17-40周),并且对运动伪影具有鲁棒性。低场胎儿MRI可用于执行高级MRI分析,是临床扫描的一种可行选择。

英文摘要:

Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R^2>0.5). This pipeline was used successfully for a wide range of GAs (17-40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.