We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the active volume of liquid-xenon time projection chambers. Low-energy helium recoils were produced by degrading $α$ particles from $^{210}$Po with a gold foil situated on the cathode of a liquid xenon time-projection chamber. The resulting population of helium recoil events is well separated from electron recoils and is also offset from the expected position of xenon nuclear recoil events.
We perform a theoretical study of the scintillation efficiency in the low-energy region crucial for liquid-xenon dark-matter detectors. We develop a computer program to simulate the cascading process of the recoiling xenon nucleus in liquid xenon and calculate the nuclear quenching effect due to atomic collisions. We use the electronic stopping power extrapolated from the experimental data to the low-energy region, and take into account the effects of electrons escaping from the electron-ion pair recombination using the generalized Thomas-Imel model fitted to scintillation data. Our result agr…
Nuclear Recoil Migdal Effect in Liquid Xenon Dark Matter Experiments
Lawrence Livermore National Laboratory (LLNL)(劳伦斯利弗莫尔国家实验室);University of California, Santa Barbara(加州大学圣塔芭芭拉分校);C.N. Yang Institute for Theoretical Physics, Stony Brook University(纽约州立大学石溪分校陈省身理论物理研究所);SLAC National Accelerator Laboratory(斯坦福直线加速器中心)
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models, but few xenon recoil calibrations above 100 keV are currently available. In this work, we measured the scintillation and ionization yields of xenon recoils up to 426 keV. The experiment uses 14.1 MeV neutrons to scatter off xenon in a compact liquid xenon time projection chamber and produce quasi-monoenergetic xenon recoils between 39 keV and 426 keV. We rep…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. The measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted $γ$ cascades can provide the nuclei with up to $0.3$ keV$_\text{nr}$ of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below…
The ionization yield in the two-phase liquid xenon dark-matter detector has been studied in keV nuclear-recoil energy region. The newly-obtained nuclear quenching as well as the recently-measured average energy required to produce an electron-ion pair are used to calculate the total electric charges produced. To estimate the fraction of the electron charges collected, the Thomas-Imel model is generalized to describing the field dependence for nuclear recoils in liquid xenon. With free parameters fitted to experiment measured 56.5 keV nuclear recoils, the energy dependence of ionization yield f…
Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below $0.3$ keV$_\text{NR}$ via the asymmetric emission of $γ$ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimi…
Low-energy electronic recoil caused by solar neutrinos in multi-ton xenon detectors is an important subject not only because it is a source of the irreducible background for direct searches of weakly-interacting massive particles (WIMPs), but also because it provides a viable way to measure the solar $pp$ and $^{7}\textrm{Be}$ neutrinos at the precision level of current standard solar model predictions. In this work we perform $\textit{ab initio}$ many-body calculations for the structure, photoionization, and neutrino-ionization of xenon. It is found that the atomic binding effect yields a siz…
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ~ 30 ns…
The search for dark matter, the missing mass of the Universe, is one of the most active fields of study within particle physics. The XENON1T experiment recently observed a 3.5$σ$ excess potentially consistent with dark matter, or with solar axions. Here, we will use the Noble Element Simulation Technique (NEST) software to simulate the XENON1T detector, reproducing the excess. We utilize different detector efficiency and energy reconstruction models, but they primarily impact sub-keV energies and cannot explain the XENON1T excess. However, using NEST, we can reproduce their excess in multiple,…
We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm, using a three-dimensional sensitive liquid xenon time projection chamber with high energy and position resolutions. Our measurement of signal responses to nuclear recoils agrees with predictions from the NEST model. However, our measured ionization (scintillation) yields for electronic recoils are consistently higher (lower) than those from the NEST model by ab…
Measuring dark matter (DM) signals via electron recoil provides an important means for direct detection of light DM particles. The recent XENON1T anomaly with electron recoil energy around $\,E_R^{}\!=\!(2-3)$keV can be naturally explained by DM inelastic scattering which injects energy to the recoiled electrons and gives a narrow peak structure in the recoil spectrum. We present an effective field theory (EFT) approach to exothermic inelastic DM signals for the Xenon electron recoil detection. For relatively heavy mediator, we fairly formulate the DM-lepton interactions by effective contact o…
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further inves…
Taking liquid xenon detectors as a case study, the importance of a robust recoil energy calibration as a prerequisite to a search for light-mass Weakly Interacting Massive Particles (WIMPs) is emphasized. Important shortfalls in the analysis of existing measurements of the relative scintillation efficiency and ionization yield for nuclear recoils in liquid xenon are described, leading to the conclusion that recent attempts to extract light-WIMP sensitivity limits from the XENON10 and XENON100 detectors are premature and overly optimistic.
Dual-phase liquid xenon (LXe) detectors lead the direct search for particle dark matter. Understanding the signal production process of nuclear recoils in LXe is essential for the interpretation of LXe based dark matter searches. Up to now, only two experiments have simultaneously measured both the light and charge yield at different electric fields, neither of which attempted to evaluate the processes leading to light and charge production. In this letter, results from a neutron calibration of liquid xenon with simultaneous light and charge detection are presented for energies from 3-74 keV, …
High pressure gas detectors offer advantages for the detection of rare events, where background reduction is crucial. For the neutrinoless double beta decay of 136Xe a high pressure xenon gas Time Projection Chamber (TPC) combines a good energy resolution and a detailed topological information of each event. The ionization topology of the double beta decay event of 136Xe in gaseous xenon has a characteristic shape defined by the two straggling electron tracks ending up in two higher ionization charge density blobs. With a properly pixelized readout, this topological information is invaluable t…
The XENON1T collaboration recently reported an excess in electron recoil events in the energy range between $1-7\,\mathrm{keV}$. This excess could be understood to originate from the known solar neutrino flux, if neutrinos couple to a light vector-mediator with strength $g_{νN}$ that kinetically mixes with the photon with strength $χ$, and $g_{νN}χ\sim10^{-13}$. Here, we show that such coupling values can naturally arise in a renormalizable model of long-range vector-mediated neutrino self-interactions. The model could be discriminated from other explanations of the XENON1T excess by the chara…
Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\sim1\,$keV and below, the signal calibrations in liquid xenon carry large uncertainties that directly impact the assumed sensitivity of existing and future experiments. In this work, we report a new measurement of the ionization yield of nuclear recoil signals in liquid xenon down to…
We report a comprehensive study of the energy response to low-energy recoils in dual-phase xenon-based dark matter experiments. A recombination model is developed to explain the recombination probability as a function of recoil energy at zero field and non-zero field. The role of e-ion recombination is discussed for both parent recombination and volume recombination. We find that the volume recombination under non-zero field is constrained by a plasma effect, which is caused by a high density of charge carriers along the ionization track forming a plasma-like cloud of charge that shields the i…
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric …
Digital pulse shape discrimination has become readily available to distinguish nuclear recoil and electronic recoil events in scintillation detectors. We evaluate digital implementations of pulse shape discrimination algorithms discussed in the literature, namely the Charge Comparison Method, Pulse-Gradient Analysis, Fourier Series and Standard Event fitting. In addition, we present a novel algorithm based on a Laplace Transform. Instead of reducing the performance of these algorithms to a single Figure of Merit, we evaluate them as function of recoil energy. Specifically, using commercial EJ-…
Inelastic from the Other Side: Xenon Excitation Signals in Light of the LZ High-Recoil Event
Nanjing Normal University(南京师范大学);Institute of Theoretical Physics, Chinese Academy of Sciences(中国科学院理论物理研究所);University of Chinese Academy of Sciences(中国科学院大学);Xinjiang University(新疆大学)
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was emitted over a longer period of time than that of nuclear recoil events, and our method used a simple ratio of early to total scintillation light emission in a single scintillation event. Requiring an efficiency of 50% for nuclear recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2 0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee …
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predictions. Decay time of scintillation at 2.82 keV is measured to be 25 +/- 3 ns at the electric field of 3.75 kV/cm.
The usual nuclear recoil energy reconstruction employed by liquid xenon dark matter search experiments relies only on the primary scintillation photon signal. Energy reconstruction based on both the photon and electron signals yields a more accurate representation of search results. For a dark matter particle mass m~10 GeV, a nuclear recoil from a scattering event is more likely to be observed in the lower left corner of the typical search box, rather than near the nuclear recoil calibration centroid. In this region of the search box, the actual nuclear recoil energies are smaller than the usu…
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of $\sim$100 keV, we observe an electronic recoil background acceptance of $<10^{-5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of …
We scrutinize the XENON1T electron recoil excess in the scalar-singlet-extended dark matter effective field theory. We confront it with various astrophysical and laboratory constraints both in a general setup and in the more specific, recently proposed, variant with leptophilic $Z_2$-odd mediators. The latter also provide mass to the light leptons via suppressed $Z_2$ breaking, a structure that is well fitting with the nature of the observed excess and the discrete symmetry leads to non-standard dark-matter interactions. We find that the excess can be explained by neutrino--electron interactio…
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe. $^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the result…
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with injected tritiated methane or $^{220}$Rn source, and with $^{241}$Am-Be neutron source, within an energy range from $1-25$ keV (ER) and $4-80$ keV (NR), under the two drift fields of 400 and 317 V/cm. An empirical model is used to fit the light yield and charge yield for both types of recoils. The best fit models can well describe the calibration data. The sys…
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is fo…
The effect of the chosen analysis energy window on the results of a dark matter experiment is exemplified by the curious intersection of the exclusion plots of the XENON10 and the CDMS experiments. After proving that the narrow energy window XENON10 chose to analyze is indeed the cause of such intersection, a method to determine the high-energy extreme of the recoil energy window an experiment should use is obtained.
The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihoo…
We report an absolute energy response function to electronic and nuclear recoils for germanium and liquid xenon detectors. As a result, we show that the detection energy threshold of nuclear recoils for a dual-phase xenon detector can be a few keV for a given number of detectable photoelectrons. We evaluate the average energy expended per electron-hole pair to be $\sim$3.32 eV, which sets a detection energy threshold of $\sim$2.15 keV for a germanium detector at 50 mini-Kelvin at 69 volts with a primary phonon frequency of 1 THz. The Fano factors of nuclear and electronic recoils that constrai…
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies above 15 keV. This novel method will be applied for background rejection in the CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) experiment looking for dark matter Weakly Interactin…
Detection of electron recoils by dark matter (DM) may reveal the structure of the dark sector. We consider a scenario where a heavier DM particle inelastically scatters off an electron and is converted into a lighter DM particle. A small mass difference between the two DM particles is transferred into electron recoil energy. We investigate the DM-electron interaction mediated by a massive dark photon and evaluate the inelastic DM scattering rate, taking account of the atomic structure. It is found that the scattering rate is significantly enhanced because of the small mass splitting, which all…
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the Jinping Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low level…
We propose a decaying cold dark matter model to explain the excess of electron recoil observed at the XENON1T experiment. In this scenario, the daughter dark matter from the parent dark matter decay easily obtains velocity large enough to saturate the peak of the electron recoil energy around 2.5 keV, and the observed signal rate can be fulfilled by the parent dark matter with a mass of order 10-200 MeV and a lifetime larger than the age of Universe. We verify that this model is consistent with experimental limits from dark matter detections, Cosmic Microwave Background and Large Scale Structu…
We study the sensitivity of future xenon- and argon-based dark matter and neutrino detection experiments to low-energy atmospheric neutrinos. Not accounting for experimental backgrounds, the primary obstacle for identifying nuclear recoils induced by atmospheric neutrinos is the tail of the electron recoil distribution due to $pp$ solar neutrinos. We use the NEST code to model the solar and atmospheric neutrino signals in a xenon detector and find that an exposure of 700 tonne-years will produce a $5σ$ detection of atmospheric neutrinos. We explore the effect of different detector properties a…
A two-phase argon detector has high discrimination power between electron recoil and nuclear recoil events based on the pulse shape discrimination and the ionization/scintillation ratio (S2/S1). This character is very suitable for the dark matter search to establish the low background experiment. However, the basic properties of S2/S1 of argon are not well known, as compared with xenon. We report the evaluation of S2/S1 properties with a two-phase detector at drift-fields of 0.2-3.0 kV/cm. Finally, the discrimination power against electron recoil background of S2/S1 is discussed.
Savage et al. have recently put forward the claim that results from the XENON10 experiment are incompatible with the totality of both DAMA/LIBRA and CoGeNT experimental regions. In this brief note the source of this erroneous conclusion is identified in a misinterpretation of the XENON10 efficiency in the detection of S1 light from low-energy nuclear recoils.
The identity of dark matter is being sought with increasingly sensitive and voluminous underground detectors. Recently the XENON1T collaboration reported excess electronic recoil events, with most of these having recoil energies around $1-30$ keV. We show that a straightforward model of inelastic dark matter produced via early universe thermal freeze-out annihilation can account for the XENON1T excess. Remarkably, this dark matter model consists of a few simple elements: sub-GeV mass Dirac fermion dark matter coupled to a lighter dark photon kinetically mixed with the Standard Model photon. A …
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.
A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is instrumented with a CCD camera for near-IR bubble imaging, a solar-blind photomultiplier tube to detect 175-nm xenon scintillation light, and a piezoelectric acoustic transducer to detect the ultrasonic emission from a growing bubble. The time of nucleation determined from the acoustic signal is used to correlate specific scintillation pulses with bubble-nucleating…
We propose models of Dark Matter that account for the 511 keV photon emission from the Galactic Centre, compatibly with experimental constraints and theoretical consistency, and where the relic abundance is achieved via p-wave annihilations or, in inelastic models, via co-annihilations. Due to the Dark Matter component that is inevitably upscattered by the Sun, these models generically predict keV electron recoils at detectors on Earth, and could naturally explain the excess recently reported by the XENON1T collaboration. The very small number of free parameters make these ideas testable by de…
We propose a new candidate of GeV scale inelastic dark matter (DM). Our construction has an anomaly-free $U(1)_X^{}$ gauge group with dark photon mediator, and can realize either scalar or fermionic inelastic DM. It is highly predictive and testable. We study the scattering rate of light inelastic DM with electrons in the XENON1T experiment and with nuclei in the XENON1T, CRESST-III, CDEX-1B and DarkSide-50 experiments. We resolve the recent XENON1T anomaly via electron recoil detection. Combining the XENON1T constraints from both electron recoils and nuclear recoils (including Migdal effect),…
With large active volume sizes dark matter direct detection experiments are sensitive to solar neutrino fluxes. Nuclear recoil signals are induced by $^8$B neutrinos, while electron recoils are mainly generated by the pp flux. Measurements of both processes offer an opportunity to test neutrino properties at low thresholds with fairly low backgrounds. In this paper we study the sensitivity of these experiments to neutrino magnetic dipole moments assuming 1, 10 and 40 tonne active volumes (representative of XENON1T, XENONnT and DARWIN), 0.3 keV and 1 keV thresholds. We show that with nuclear re…
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $β$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated tem…
We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We mea…
There exist well motivated models of particle dark matter which predominantly scatter inelastically off nuclei in direct detection experiments. This inelastic transition causes the DM to up-scatter in terrestrial experiments into an excited state up to 550 keV heavier than the DM itself. An inelastic transition of this size is highly suppressed by both kinematics and nuclear form factors. We extend previous studies of inelastic DM to determine the present bounds on the scattering cross section, and the prospects for improvements in sensitivity. Three scenarios provide illustrative examples: ne…
This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fl…
The LUX dark matter search experiment is a 350 kg dual-phase xenon time projection chamber located at the 4850 ft level of the Sanford Underground Research Facility in Lead, SD. The success of two-phase xenon detectors for dark matter searches relies on their ability to distinguish electron recoil (ER) background events from nuclear recoil (NR) signal events. Typically, the NR-ER discrimination is obtained from the ratio of the electroluminescence light (S2) to the prompt scintillation light (S1). Analysis of the S1 pulse shape is an additional discrimination technique that can be used to dist…
The dark matter interpretation for a recent observation of excessive electron recoil events at the XENON1T detector seems challenging because its velocity is not large enough to give rise to recoiling electrons of $\mathcal{O}({\rm keV})$. Fast-moving or boosted dark matter scenarios are receiving attention as a remedy for this issue, rendering the dark matter interpretation a possibility to explain the anomaly. We investigate various scenarios where such dark matter of spin 0 and 1/2 interacts with electrons via an exchange of vector, pseudo-scalar, or scalar mediators. We find parameter valu…
Direct detection of solar chameleons with electron recoil data from XENONnT
University of Trento(特伦托大学);Trento Institute for Fundamental Physics and Applications (TIFPA)-INFN(特伦托基础物理与应用研究所(TIFPA)-意大利国家核物理研究所);University of Cambridge(剑桥大学);Kavli Institute for Cosmology (KICC), University of Cambridge(剑桥大学卡弗里宇宙学研究所);Universidad de Zaragoza(萨拉戈萨大学);Centro de Astropartículas y Física de Altas Energías, Universidad de Zaragoza(萨拉戈萨大学高能天体粒子物理中心);University of Salerno(萨莱诺大学);INFN Sezione di Napoli, Gruppo Collegato di Salerno(意大利国家核物理研究所那不勒斯分部萨莱诺协作组);Technische Universität Dortmund(多特蒙德工业大学)