arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2308.02088eess.IVeess.SP

运动鲁棒的自由运行式容积心血管MRI

Motion-robust free-running volumetric cardiovascular MRI

Syed M. Arshad, Lee C. Potter, Chong Chen, Yingmin Liu, Preethi Chandrasekaran, Christopher Crabtree, Matthew S. Tong, Orlando P. Simonetti, Yuchi Han, Rizwan Ahmad

AI总结:

本研究提出名为CORe的异常值拒绝方法,通过加性辅助变量建模异常值并结合MR物理引导的组稀疏约束联合估计图像,经仿真与多组临床CMR数据验证,可有效抑制运动伪影、提升图像质量与血流测量可靠性,相关代码数据已开源。

摘要:

目的:提出并评估一种异常值抑制方法,使自由运行式容积心血管MRI(CMR)对运动更具鲁棒性。方法:所提出的方法名为带异常值拒绝的压缩恢复(compressive recovery with outlier rejection, CORe),将测量数据中的异常值建模为加性辅助变量。我们对该辅助变量施加MR物理引导的组稀疏约束,并通过迭代算法将其与图像联合估计。为进行评估,首先通过两项仿真研究将CORe与传统压缩感知(compressed sensing, CS)、鲁棒回归(robust regression, RR)及一种现有的异常值拒绝方法进行对比;随后使用7个三维(3D)电影成像数据集、12个静息态四维(4D)血流成像数据集和8个负荷态4D血流成像数据集,将CORe与CS进行对比。结果:仿真研究显示,在55种不同实现场景下,CORe在归一化均方误差和结构相似性指数方面均优于CS、RR及现有异常值拒绝方法。专家对3D电影图像的阅片评估表明,CORe在抑制伪影方面更有效,同时可保持或提升图像清晰度。最后,4D血流图像显示CORe能产生更可靠、更一致的血流测量结果,尤其是在受试者存在不自主运动或运动负荷的情况下。结论:本文提出了一种异常值拒绝方法,并通过仿真数据和实测数据对其进行了测试。该方法可在多种自由运行式CMR应用中帮助抑制运动伪影。代码与数据:实现代码和数据集可在GitHub获取,地址为http://github.com/OSU-MR/motion-robust-CMR。

英文摘要:

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications. CODE & DATA: Implementation code and datasets are available on GitHub at http://github.com/OSU-MR/motion-robust-CMR

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑