arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2004.14462eess.IVphysics.med-phq-bio.QM

Manual segmentation versus semi-automated segmentation for quantifying vestibular schwannoma volume on MRI

Hari McGrath, Peichao Li, Reuben Dorent, Robert Bradford, Shakeel Saeed, Sotirios Bisdas, Sebastien Ourselin, Jonathan Shapey, Tom Vercauteren

英文摘要:

Management of vestibular schwannoma (VS) is based on tumour size as observed on T1 MRI scans with contrast agent injection. Current clinical practice is to measure the diameter of the tumour in its largest dimension. It has been shown that volumetric measurement is more accurate and more reliable as a measure of VS size. The reference approach to achieve such volumetry is to manually segment the tumour, which is a time intensive task. We suggest that semi-automated segmentation may be a clinically applicable solution to this problem and that it could replace linear measurements as the clinical standard. Using high-quality software available for academic purposes, we ran a comparative study of manual versus semi-automated segmentation of VS on MRI with 5 clinicians and scientists. We gathered both quantitative and qualitative data to compare the two approaches; including segmentation time, segmentation effort and segmentation accuracy. We found that the selected semi-automated segmentation approach is significantly faster (167s versus 479s, p<0.001), less temporally and physically demanding and has approximately equal performance when compared with manual segmentation, with some improvements in accuracy. There were some limitations, including algorithmic unpredictability and error, which produced more frustration and increased mental effort in comparison to manual segmentation. We suggest that semi-automated segmentation could be applied clinically for volumetric measurement of VS on MRI. In future, the generic software could be refined for use specifically for VS segmentation, thereby improving accuracy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑