arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2305.08752cs.HCcs.LG
收藏

标注的问题:基于可穿戴传感器的原位与自我回忆活动标注的实证研究

A Matter of Annotation: An Empirical Study on In Situ and Self-Recall Activity Annotations from Wearable Sensors

University of Siegen(锡根大学);Ubiquitous Computing(普适计算);Siegen(锡根)

Alexander Hoelzemann, Kristof Van Laerhoven

AI总结:

该研究针对可穿戴传感器活动检测,对比了四种活动标注方法,发现原位标注精度更高,结合活动日志与可视化工具可提升标注质量与模型F1值,并讨论了方法优劣与偏差影响。

摘要:

基于可穿戴传感器的人类活动检测研究是一个高度活跃的领域,可为诸多应用带来裨益,涵盖医疗患者的动态监测、健身指导,以及简化手工作业流程等方面。\n我们开展了一项实证研究,针对真实环境下数据采集的用户研究中四种常用的标注方法进行评估与对比。无论是用户驱动的原位标注(参与者在实际记录过程中标注自身活动),还是回忆式标注方法(参与者在每天结束时回溯标注其数据),参与者都可灵活选择自己的活动类别集合及对应标签。\n我们的研究表明,不同的标注方法会直接影响标注质量,以及利用这些数据训练的深度学习分类器的性能。我们发现,与回忆式方法相比,原位方法生成的标签数量更少但精度更高。此外,我们将活动日志与可视化工具相结合,让参与者能够查看并标注自己的活动数据。由于引入了该工具,我们得以减少标注缺失并提升标注一致性,进而使深度学习模型的F1-Score最高提升了8%(F1-Score区间为82.1%至90.4%)。我们还讨论了研究中所对比方法的优缺点、它们可能引入的偏差、其使用对人类活动识别研究的影响,以及可能的解决方案。

英文摘要:

Research into the detection of human activities from wearable sensors is a highly active field, benefiting numerous applications, from ambulatory monitoring of healthcare patients via fitness coaching to streamlining manual work processes. We present an empirical study that evaluates and contrasts four commonly employed annotation methods in user studies focused on in-the-wild data collection. For both the user-driven, in situ annotations, where participants annotate their activities during the actual recording process, and the recall methods, where participants retrospectively annotate their data at the end of each day, the participants had the flexibility to select their own set of activity classes and corresponding labels. Our study illustrates that different labeling methodologies directly impact the annotations' quality, as well as the capabilities of a deep learning classifier trained with the data. We noticed that in situ methods produce less but more precise labels than recall methods. Furthermore, we combined an activity diary with a visualization tool that enables the participant to inspect and label their activity data. Due to the introduction of such a tool were able to decrease missing annotations and increase the annotation consistency, and therefore the F1-Score of the deep learning model by up to 8% (ranging between 82.1 and 90.4% F1-Score). Furthermore, we discuss the advantages and disadvantages of the methods compared in our study, the biases they could introduce, and the consequences of their usage on human activity recognition studies as well as possible solutions.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑