MITICA实验(ITER加热中性束注入器原型)中1 MV电源的局部放电检测
Partial Discharges detection in 1 MV power supplies in MITICA experiment, the ITER Heating Neutral Beam Injector prototype
AI总结:
本文针对MITICA实验中1 MV高压电源在调试期间发生的击穿问题,升级了局部放电检测诊断系统,通过仪器直流适用性鉴定、灵敏度评估及逐步加压寻找电晕现象,成功识别了高压装置中的潜在绝缘薄弱点。
摘要:
MITICA(Megavolt ITER Injector & Concept Advancement)是ITER加热中性束的全尺寸原型,目前正在Neutral Beam Test Facility(意大利帕多瓦)进行建造。其设计目标是通过将负氘离子加速至1 MeV以获得40 A的总离子流,随后进行中和,从而向ITER等离子体输送16.5 MW的能量。MITICA加速电源由多台非标准设备组成,其绝缘电压等级(-1 MVdc)和尺寸均超出了工业标准。根据安装进度,在连接了属于不同采购包的设备后,分五个连续步骤(从2018年至2019年)进行了耐压试验(最高达1.265 MVdc)。在2021年开始的综合调试期间,高压装置中尚未确定的位置发生了两次击穿,因此它们可能发生在空气中或SF6中。为确定潜在绝缘薄弱点的位置,作为第一步,对用于局部放电检测(击穿的前兆)的现有诊断系统进行了升级,在空气绝缘部分增加了一套仪器设备,包括电容探头和用于交流应用的现成仪器(声学与电磁传感器)。本文探讨了仪器鉴定以评估其用于直流场景的适用性,以及在MITICA中开展的研究,具体包括:1)灵敏度评估测试,通过人工产生电晕效应来确定每种诊断系统的最小阈值;2)向MITICA装置施加电压,在设备周围移动仪器并逐步提高电压以寻找电晕现象,从而识别潜在的绝缘薄弱点。
英文摘要:
MITICA (Megavolt ITER Injector & Concept Advancement), the full scale prototype of ITER Heating Neutral Beam, is under realization at the Neutral Beam Test Facility (Padova, Italy). It is designed to deliver 16.5 MW to ITER plasma, obtained by accelerating negative Deuterium ions up to 1 MeV for a total ion current of 40 A and then neutralized. MITICA Acceleration Power Supply is composed of several non-standard equipment, beyond industrial standard for insulation voltage level (-1 MVdc) and dimensions. Voltage withstand tests (up to 1.265 MVdc) have been performed in five subsequent steps (from 2018 to 2019), according to the installation progress, after connecting equipment belonging to different procurements. During integrated commissioning, started in 2021, two breakdowns occurred in a position of the HV plant not still identified, so they could be occurred either in air or in SF6. To identify the locations of possible weak insulation points, the existing diagnostics for partial discharge detection (the precursor of breakdowns) as a first step have been improved on air-insulated parts by consisting in a set of instrumentation, like capacitive probes and off-the-shelf instruments for AC application (acoustic and electromagnetic sensors). The paper deals with the instruments qualification to assess their suitability for DC usage and then with the investigation performed in MITICA, in particular: 1) sensitivity assessment campaign, with artificially produced corona effect to identify the minimum threshold of each diagnostics 2) voltage application to MITICA plant, moving the instrumentation around equipment and increasing progressively the voltage looking for corona phenomena to identify possible weak insulation points.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。