加速非笛卡尔MRI重建的双域自监督学习

Dual-Domain Self-Supervised Learning for Accelerated Non-Cartesian MRI Reconstruction

Hyperfine Research(Hyperfine研究院);Yale University(耶鲁大学);New York University(纽约大学)

Bo Zhou, Jo Schlemper, Neel Dey, Seyed Sadegh Mohseni Salehi, Kevin Sheth, Chi Liu, James S. Duncan, Michal Sofka

摘要:

虽然能够加速采集和提高重建精度,但当前的深度MRI重建网络通常是受监督的,需要完全采样的数据,并且限于笛卡尔采样模式。这些因素限制了它们的实际应用,因为全采样MRI在临床上采集非常耗时。此外,非笛卡尔采样模式特别理想,因为它们更容易受到加速度的影响,并且显示出更好的运动鲁棒性。为此,我们提出了一个完全自我监督的方法,加速非笛卡尔MRI重建,利用自我监督在k空间和图像域。在训练中,欠采样数据被分成不相交的k空间域分区。对于k-空间自监督,我们训练一个网络来重建输入欠采样数据从不相交的分区和从本身。对于图像级的自我监督,我们强制从原始欠采样数据和两个分区获得的外观一致性。在我们模拟的多线圈非笛卡尔MRI数据集上的实验结果表明,DDSS可以生成接近完全监督重建精度的高质量重建,优于以前的基线方法。最后,DDSS被证明可以扩展到在便携式低场(0.064 T)MRI扫描仪上采集的极具挑战性的真实世界临床MRI重建,没有数据可用于监督训练,同时证明与传统重建相比,图像质量有所改善,如放射科医生研究所确定的。

英文摘要:

While enabling accelerated acquisition and improved reconstruction accuracy, current deep MRI reconstruction networks are typically supervised, require fully sampled data, and are limited to Cartesian sampling patterns. These factors limit their practical adoption as fully-sampled MRI is prohibitively time-consuming to acquire clinically. Further, non-Cartesian sampling patterns are particularly desirable as they are more amenable to acceleration and show improved motion robustness. To this end, we present a fully self-supervised approach for accelerated non-Cartesian MRI reconstruction which leverages self-supervision in both k-space and image domains. In training, the undersampled data are split into disjoint k-space domain partitions. For the k-space self-supervision, we train a network to reconstruct the input undersampled data from both the disjoint partitions and from itself. For the image-level self-supervision, we enforce appearance consistency obtained from the original undersampled data and the two partitions. Experimental results on our simulated multi-coil non-Cartesian MRI dataset demonstrate that DDSS can generate high-quality reconstruction that approaches the accuracy of the fully supervised reconstruction, outperforming previous baseline methods. Finally, DDSS is shown to scale to highly challenging real-world clinical MRI reconstruction acquired on a portable low-field (0.064 T) MRI scanner with no data available for supervised training while demonstrating improved image quality as compared to traditional reconstruction, as determined by a radiologist study.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑