The presented study aims to estimate blood pressure (BP) using photoplethysmogram (PPG) signals while employing multiple machine learning models. The study proposes a novel algorithm for signal reconstruction, which utilizes the semi-classical signal analysis (SCSA) technique. The proposed algorithm optimises the semi-classical constant and eliminates the trade-off between complexity and accuracy in reconstruction. The reconstructed signals' spectral features are extracted and incorporated with clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed method was assessed using a publicly available virtual in-silico dataset with more than 4000 subjects, and the Multi-Parameter Intelligent Monitoring in Intensive Care Units dataset. Results showed that the method attained a mean absolute error of 5.37 and 2.96 mmHg for systolic and diastolic BP, respectively, using the CatBoost supervisory algorithm. This approach met the standards set by the Advancement of Medical Instrumentation, and achieved Grade A for all BP categories in the British Hypertension Society protocol. The proposed framework performs well even when applied to a combined database of the MIMIC-III and the Queensland dataset. This study also evaluates the proposed method's performance in a non-clinical setting with noisy and deformed PPG signals, to validate the efficacy of the SCSA method. The noise stress tests showed that the algorithm maintained its key feature detection, signal reconstruction capability, and estimation accuracy up to a 10 dB SNR ratio. It is believed that the proposed cuff-less BP estimation technique has the potential to perform well on resource-constrained settings due to its straightforward implementation approach.
Benchmarking and Enhancing PPG-Based Cuffless Blood Pressure Estimation Methods
Department of Engineering Technology, University of Houston, Texas, USA(工程科技系,休斯顿大学,德克萨斯州,美国);Department of Electrical and Computer Engineering, University of Houston, Texas, USA(电气与计算机工程系,休斯顿大学,德克萨斯州,美国);Department of Information Science Technology, University of Houston, Texas, USA(信息科学科技系,休斯顿大学,德克萨斯州,美国);Department of Cardiovascular Surgery, Houston Methodist Hospital, Texas, USA(心血管外科系,休斯顿方法医院,德克萨斯州,美国);Department of Biomedical Engineering, University of Houston, Texas, USA(生物医学工程系,休斯顿大学,德克萨斯州,美国)
TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing
Faculty of Computer Science(计算机科学学院);Concordia Institute for Information Systems Engineering(康考迪亚信息系统工程学院);University of New Brunswick(新不伦瑞克大学);Concordia University(康考迪亚大学)
Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios
Faculty of Frontier Sciences, Harbin Institute of Technology, Shenzhen(前沿科学学院,哈尔滨工业大学深圳校区);University of Melbourne(墨尔本大学);University of New South Wales(新南威尔士大学)
Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation
VUNO Inc.(VUNO公司);University of California, Irvine(加州大学欧文分校);Research Institute for Future Medicine, Samsung Medical Center(三星未来医学研究所);Inha University Hospital(仁荷大学医院)
Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);University of Chinese Academy of Sciences(中国科学院大学);Hong Kong Polytechnic University(香港理工大学);Shenzhen Polytechnic University(深圳职业技术大学)