arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2301.08439eess.SP
收藏

利用PPG信号及其二阶导数的临床相关特征进行基于薛定谔谱的连续无袖带血压估计

Schrödinger Spectrum based Continuous Cuff-less Blood Pressure Estimation using Clinically Relevant Features from PPG Signal and its Second Derivative

Aayushman Ghosh, Sayan Sarkar, Jayant Kalra

摘要:

本研究旨在使用光电容积描记图(PPG)信号估计血压(BP),同时采用多种机器学习模型。提出了一种基于半经典信号分析(SCSA)的信号重构算法。所提出的算法优化了半经典常数,消除了重建的复杂性和准确性之间的权衡。提取重建信号的频谱特征,并将其与临床相关的PPG及其二阶导数(SDPPG)形态特征相结合。使用公开的虚拟计算机数据集(超过4000名受试者)和重症监护病房多参数智能监测数据集对所开发的方法进行了评估。结果表明,该方法达到了平均绝对误差为5.37和2.96毫米汞柱的收缩压和舒张压,分别使用CatBoost监督算法。这种方法符合医疗器械进步所设定的标准,并在英国高血压协会协议中达到了所有BP类别的A级。建议的框架表现良好,即使应用到MIMIC-III和昆士兰数据集的组合数据库。本研究还评估了所提出的方法在具有噪声和变形PPG信号的非临床环境中的性能,以验证SCSA方法的有效性。噪声压力测试表明,该算法保持其关键特征检测,信号重建能力,估计精度高达10 dB的信噪比。据信,所提出的无袖BP估计技术有可能在资源受限的设置,由于其简单的实现方法,表现良好。

英文摘要:

The presented study aims to estimate blood pressure (BP) using photoplethysmogram (PPG) signals while employing multiple machine learning models. The study proposes a novel algorithm for signal reconstruction, which utilizes the semi-classical signal analysis (SCSA) technique. The proposed algorithm optimises the semi-classical constant and eliminates the trade-off between complexity and accuracy in reconstruction. The reconstructed signals' spectral features are extracted and incorporated with clinically relevant PPG and its second derivative's (SDPPG) morphological features. The developed method was assessed using a publicly available virtual in-silico dataset with more than 4000 subjects, and the Multi-Parameter Intelligent Monitoring in Intensive Care Units dataset. Results showed that the method attained a mean absolute error of 5.37 and 2.96 mmHg for systolic and diastolic BP, respectively, using the CatBoost supervisory algorithm. This approach met the standards set by the Advancement of Medical Instrumentation, and achieved Grade A for all BP categories in the British Hypertension Society protocol. The proposed framework performs well even when applied to a combined database of the MIMIC-III and the Queensland dataset. This study also evaluates the proposed method's performance in a non-clinical setting with noisy and deformed PPG signals, to validate the efficacy of the SCSA method. The noise stress tests showed that the algorithm maintained its key feature detection, signal reconstruction capability, and estimation accuracy up to a 10 dB SNR ratio. It is believed that the proposed cuff-less BP estimation technique has the potential to perform well on resource-constrained settings due to its straightforward implementation approach.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑