使用扫描电子显微镜和跃迁边缘传感器光谱仪对集成电路进行纳米级三维成像

Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

Nathan Nakamura, Paul Szypryt, Amber L. Dagel, Bradley K. Alpert, Douglas A. Bennett, W. Bertrand Doriese, Malcolm Durkin, Joseph W. Fowler, Dylan T. Fox, Johna… 展开作者

Nathan Nakamura, Paul Szypryt, Amber L. Dagel, Bradley K. Alpert, Douglas A. Bennett, W. Bertrand Doriese, Malcolm Durkin, Joseph W. Fowler, Dylan T. Fox, Johnathon D. Gard, Ryan N. Goodner, J. Zachariah Harris, Gene C. Hilton, Edward S. Jimenez, Burke L. Kernen, Kurt W. Larson, Zachary H. Levine, Daniel McArthur, Kelsey M. Morgan, Galen C. O'Neil, Nathan J. Ortiz, Christine G. Pappas, Carl D. Reintsema, Daniel R. Schmidt, Peter A. Schultz, Kyle R. Thompson, Joel N. Ullom, Leila Vale, Courtenay T. Vaughan, Christopher Walker, Joel C. Weber, Jason W. Wheeler, Daniel S. Swetz

AI总结:

本文提出结合SEM电子束与TES微热量计的实验室级X射线纳米断层扫描系统,实现了集成电路中160 nm特征的三维元素特异性成像。

摘要:

X射线纳米断层扫描是表征纳米级材料和结构的强大工具,但由于对X射线通量和光斑尺寸的要求相互冲突,因此难以实施。受此限制,最先进的纳米断层扫描主要在大型同步加速器设施中进行。我们提出了一种实验室规模的纳米断层扫描仪器,可在实现纳米级空间分辨率的同时改变传统断层扫描工具的局限。该仪器将扫描电子显微镜(SEM)的电子束与超导跃迁边缘传感器(TES)微热量计的精确宽带X射线检测相结合。电子束在距目标样品数微米的金属靶中产生高度聚焦的X射线光斑,而TES光谱仪则以高信噪比分离靶光子。聚焦X射线光斑、能量分辨X射线检测以及独特系统几何结构的这种结合,使紧凑装置中能够实现纳米级、元素特异性的X射线成像。通过对Cu-SiO2集成电路6层中的160 nm特征进行三维成像,证明了这种X射线纳米断层扫描方法的概念验证,并讨论了实现更精细分辨率和增强成像能力的路径。

英文摘要:

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.