arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2207.07089cs.LGcs.CV
收藏

一种个性化零样本心电图心律失常监测系统:从基于稀疏表示的域适应到面向实用心电图监测的节能异常心拍检测

A Personalized Zero-Shot ECG Arrhythmia Monitoring System: From Sparse Representation Based Domain Adaption to Energy Efficient Abnormal Beat Detection for Practical ECG Surveillance

Tampere University(坦佩雷大学);Qatar University(卡塔尔大学)

Mehmet Yamaç, Mert Duman, İlke Adalıoğlu, Serkan Kiranyaz, Moncef Gabbouj

AI总结:

本文提出一种个性化零样本ECG心律失常监测系统,通过稀疏字典学习的零空间分析和基于稀疏表示的域适应技术,在无需新用户异常心跳的情况下训练分类器,实现了98.2%的准确率和节能监测。

摘要:

本文提出了一种低成本且高精度的ECG监测系统,旨在为可穿戴移动传感器提供个性化的早期心律失常检测。早期的个性化ECG监测监督方法需要异常和正常心跳来训练专用分类器。然而,在个性化算法嵌入可穿戴设备的真实场景中,对于没有心脏病史的健康人来说,这种训练数据是无法获取的。在本研究中,我们提出对通过稀疏字典学习获得的健康信号空间进行零空间分析,并研究简单的零空间投影或基于正则化最小二乘法的分类方法如何在不牺牲检测精度的情况下,降低与基于稀疏表示的分类相比的计算复杂度。然后,我们引入一种基于稀疏表示的域适应技术,将其他现有用户的异常和正常信号投影到新用户的信号空间上,使我们能够在没有新用户任何异常心跳的情况下训练专用分类器。因此,无需生成合成异常心跳即可实现零样本学习。在基准MIT-BIH ECG数据集上进行的大量实验表明,当这种基于域适应的训练数据生成器与简单的1-D CNN分类器一起使用时,该方法以显著优势优于先前的工作。接着,通过结合上述两点,我们提出了一种集成分类器,进一步提升了性能。这种用于零样本心律失常检测的方法达到了98.2%的平均准确率和92.8%的F1-Score。最后,利用上述创新提出了一种个性化节能ECG监测方案。

英文摘要:

This paper proposes a low-cost and highly accurate ECG-monitoring system intended for personalized early arrhythmia detection for wearable mobile sensors. Earlier supervised approaches for personalized ECG monitoring require both abnormal and normal heartbeats for the training of the dedicated classifier. However, in a real-world scenario where the personalized algorithm is embedded in a wearable device, such training data is not available for healthy people with no cardiac disorder history. In this study, (i) we propose a null space analysis on the healthy signal space obtained via sparse dictionary learning, and investigate how a simple null space projection or alternatively regularized least squares-based classification methods can reduce the computational complexity, without sacrificing the detection accuracy, when compared to sparse representation-based classification. (ii) Then we introduce a sparse representation-based domain adaptation technique in order to project other existing users' abnormal and normal signals onto the new user's signal space, enabling us to train the dedicated classifier without having any abnormal heartbeat of the new user. Therefore, zero-shot learning can be achieved without the need for synthetic abnormal heartbeat generation. An extensive set of experiments performed on the benchmark MIT-BIH ECG dataset shows that when this domain adaptation-based training data generator is used with a simple 1-D CNN classifier, the method outperforms the prior work by a significant margin. (iii) Then, by combining (i) and (ii), we propose an ensemble classifier that further improves the performance. This approach for zero-shot arrhythmia detection achieves an average accuracy level of 98.2% and an F1-Score of 92.8%. Finally, a personalized energy-efficient ECG monitoring scheme is proposed using the above-mentioned innovations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑