Nanoscale structure determination belongs to one of the crucial tasks in materials science. Small-angle neutron scattering (SANS) is a highly valuable tool to investigate nanostructures. Here, we explore the possibility of a compact SANS instrument to be installed at an individual accelerator based pulsed low-flux source, and discuss applications in structural characterization, education, and training. Monte Carlo simulations of a realistic setup demonstrate the feasibility of such an instrument, with an ideal measurement taking about 7 hours. The anticipated length-scale measurement range is 0.5 nm to 50 nm. The minimalistic design results in an easy to operate, low maintenance instrument, independent of the schedules of large-scale facilities. Size, cost, and maintenance are comparable to laboratory small-angle X-ray scattering (SAXS) instruments, which makes SANS affordable for individual research teams at universities and provides unique chances for education and training. The proposed setup creates the opportunity to measure ultraslow structural changes, at a fraction of the cost of existing SANS instruments, hence enables weekly or monthly repetition rates. The concept can be expanded to an entire suite of instruments, including wide-angle neutron scattering (WANS) and diffraction, neutron reflectometry (NR), neutron radiography, grating interferometry (GI), and prompt gamma activation analysis (PGAA).
There is currently a strong interest in Compact Accelerator-based Neutron Source (CANS) as a possible new type of source for neutron scattering experiments. A workshop around the "Neutron scattering instrumentation around CANS" was organized in July 2017 between several European institutes. This report summarizes the main outcome of the discussions. The document is aiming at providing general guidelines for the instrumentation around CANS. Detailed technical discussions are or will be provided in specific publications.
Small-angle neutron scattering (SANS) is the most significant neutron technique in terms of impact on science and engineering. However, the basic concept of SANS facilities has not changed since the technique's inception about 40 years ago, as all SANS instruments, save a few, are still designed as pinhole cameras. Here we demonstrate a novel concept for a SANS instrument, based on axisymmetric focusing mirrors. We build and test a small prototype, which shows a performance comparable to that of conventional large SANS facilities. By using a detector with 50-micron pixels, we build the most co…
Simple and fast analytic method to find out optimal combinations of sizes of neutron moderator and optical system entrance, allowing for the full sample illumination with minimum to none background, is developed. In the case of employing low-dimensional para-hydrogen moderators with enhanced neutron beam brilliance, the method allows to determine the minimum size of moderator, which provides the highest sample flux while keeping the sample fully illuminated. This method can be used during the design of new neutron sources, upgrades of neutron optical systems and moderator replacements.
The design and characteristics of a double supermirror monochromator for neutron instrumentation at the Laboratoire Leon Brillouin is described. The aim of this monochromator is to reduce the intense gamma-radiation produced by conventional velocity selectors and to avoid a direct view of the guide while keeping a comparable neutron transmission (higher than 70%). The monochromator offers a continuous choice of wavelength selection in the range 0.5 to 2 nm.
The concept of the instrument with absorption gratings into small-angle neutron scattering measuring is discussed. The instrument action consists of passing direct and scattered radiation through a system of 3 absorption gratings, consisting of periodic transparent and absorbing strips. The instrument operates in a mode of geometric optics. The principle of operation of the instrument is demonstrated on a prototype created for optical radiation. For the instrument equations of the radiation transmission and the display of the sample, scattering function has been derived. The necessary paramete…
Building the European Spallation Source (ESS), the most powerful neutron source in the world, requires significant technological advances at most fronts of instrument component design. Detectors are not an exception. The existing implementations at current neutron scattering facilities are at their performance limits and sometimes barely cover the scientific needs. At full operation the ESS will yield unprecedented neutron brilliance. This means that one of the most challenging aspects for the new detector designs is the increased rate capability and in particular the peak instantaneous rate c…
Polarized neutrons are a powerful probe to investigate magnetism in condensed matter on length scales from single atomic distances to micrometers. With the ongoing advancement of neutron optics, that allow to transport beams with increased divergence, the demands on neutron polarizes and analyzers have grown as well. The situation becomes especially challenging for new instruments at pulsed sources, where a large wavelength band needs to be polarized to make efficient use of the time structure of the beam. Here we present a polarization analysis concept for highly focused neutron beams that is…
Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, materials analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic …
Like every megaproject, the European Spallation Source (ESS) currently under construction in Lund, Sweden, has had to make a number of inevitable compromises to remain within budget and on schedule. Some of these compromises carry technical consequences with a potential impact on the operational characteristics of the facility and the neutron scattering instruments in particular. In order to prepare for operation of the facility, it is timely to consider again the subjects of instrument backgrounds and shielding from the project design phase. The expected ranges of instrument backgrounds, and …
Expanding Neutron Capacity at the ESS through Symbiotic Instruments: SLEIPNIR & Remora
Department of Physics, Technical University of Denmark(丹麦技术大学物理系);Data Management & Scientific Computing, European Spallation Source ERIC(欧洲散裂源ERIC数据管理与科学计算部);Spectroscopy Division, European Spallation Source ERIC(欧洲散裂源ERIC光谱学部);Jülich Centre for Neutron Science(朱利希中子科学中心);Heinz Maier-Leibnitz Zentrum, Technical University of Munich(慕尼黑大学海因茨·迈尔-莱布尼茨中心)
The control systems of all neutron scattering instruments implemented by the Jülich Centre for Neutron Science (JCNS) are based on Siemens PLC technology. Historically PROFIBUS has been used for the communication of PLCs with supervisory computers, decentral periphery systems and other PLCs. Today, PROFINET IO is the most commonly used industrial real time Ethernet system and naturally supported by Siemens PLC systems. As a consequence, all new neutron instruments of JCNS are based on PROFINET IO. For the interfacing to supervisory computers based on CompactPCI, a CompactPCI carrier board for …
It is generally assumed by most of the small-angle neutron scattering (SANS) user community that a neutrons energy is unchanged during SANS measurements. Here, the scattering from water, specifically light water, was measured on the EQ-SANS instrument, a time-of-flight SANS instrument located at the Spallation Neutron Source of Oak Ridge National Laboratory. A significant inelastic process was observed in the TOF spectra of neutrons scattered from water. Analysis of the TOF spectra from the sample showed that the scattered neutrons have energies consistent with room-temperature thermal energie…
In Chinese Spallation Neutron Source (CSNS), proton beam is used to hit metal tungsten target, and then high flux neutrons are generated for experiments on instruments. For neutron flux spectrum correction, boron-coated GEM, lithium glass and 3He are used as neutron beam monitor in instruments. To be integrated into neutron instrument control, a new DAQ software for neutron beam monitor is developed, called NEROS (Neutron Event Readout System). NEROS is based on EPICS V4 and a unified data format for CSNS neutron beam monitor is defined. The framework and software design of NEROS is introduced…
We present a preliminary design for a novel neutron detection system that is compact, lightweight, and low power consuming, utilizing the CubeSat platform making it suitable for space-based applications. This is made possible using the scintillating crystal lithium indium diselenide ($^6$LiInSe$_2$), the first crystal to include $^6$Li in the crystalline structure, and a silicon avalanche photodiode (Si-APD). The schematics of this instrument are presented as well as the response of the instrument to initial testing under alpha radiation. A principal aim of this work is to demonstrate the feas…
An instrument and software algorithm is described for the purpose of characterization of large single crystals at the Alignment Facility (ALF) of the ISIS spallation neutron source. We describe a method for both characterizing the quality of the sample and also aligning it in a particular scattering plane. We present a software package written for this instrument and demonstrate its utility by way of an example of the structural characterization of large singles crystals of Pb(Mg$_{1/3}$Nb$_{2/3}$)O$_{3}$. We suggest extensions and modifications of characterization instruments for future impro…
A new Small Angle Neutron Scattering instrument is proposed for the European Spallation Source. The pulsed source requires a time-of-flight analysis of the gathered neutrons at the detector. The optimal instrument length is found to be rather large, which allows for a polarizer and a versatile collimation. The polarizer allows for studying magnetic samples and incoherent background subtraction. The wide collimation will host VSANS and SESANS options that increase the resolution of the instrument towards um and tens of um, respectively. Two 1m2 area detectors will cover a large solid angle simu…
This artcile presents an optimisation of performance and cost of neutron scattering instrumentation at the European Spallation Source. This is done by trading detailed cost functions against beam transmission functions in a multi-dimensional, yet simple, parameter space. On the one hand, the neutron guide cost increases as a power of the desired beam divergence, and inversely with the minimum wavelength, due to the supermirror coating needed. On the other hand, the more neutrons are transported to the instrument the greater are the shielding costs to deal with the gamma rays that result from t…
The neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio-frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, a…
A growing community of scientists has been using neutrons in the most diverse areas of science. In order to meet the researchers demand in the areas of physics, chemistry, materials sciences, engineering, cultural heritage, biology and earth sciences, the Brazilian Multipurpose Reactor (RMB) will provide 3 thermal guides and 3 cold guides, with the installation of several instruments for materials characterization. In this study, we present a standard design requirement of two primordial instruments, namely Sabiá and Araponga. They are, respectively, cold and thermal neutron instruments and co…
We describe theoretical and practical aspects of spin-echo modulated small-angle neutron scattering (SEMSANS) as well as the potential combination with SANS. Based on the preliminary technical designs of SKADI (a SANS instrument proposed for the European Spallation Source) and a SEMSANS add-on, we assess the practicability, feasibility and scientific merit of a combined SANS and SEMSANS setup by calculating tentative SANS and SEMSANS results for soft matter, geology and advanced material samples that have been previously studied by scattering methods. We conclude that lengths from 1 nm up to 0…
We propose and design novel axisymmetric focusing mirrors, known as Wolter optics, for small-angle neutron scattering instruments. Ray-tracing simulations show that using the mirrors can result in more than an order-of-magnitude increase in the neutron flux reaching detectors, while decreasing the minimum wave vector transfer. Such mirrors are made of Ni using a mature technology. They can be coated with neutron supermirror multilayers, and multiple mirrors can be nested to improve their flux-collection ability. Thus, these mirrors offer simple and flexible means of significantly improving exi…
A new method for analyzing collimation angle of neutron Soller collimator is described. Gaussian distribution formula is used to define the angle distribution function of neutron source and neutron transmission function of Soller collimator. A relationship between FWHM of collimator rocking curve and collimation angle is derived.
The main objective of the European Spallation Source (ESS) is to perform consistently high impact neutron scattering science using the highest neutron flux of any facility in its class. This ambition is naturally accompanied by operational challenges related to the vertical integration of the instruments' hardware and software shared between collaborators from 13 European countries. The present work will detail integration tests performed at the V20 Test Instrument at Helmholtz-Zentrum Berlin in Germany. An ESS chopper prototype was successfully controlled through the ESS Chopper Integration C…
Inelastic neutron scattering instruments require very low background; therefore the proper shielding for suppressing the scattered neutron background, both from elastic and inelastic scattering is essential. The detailed understanding of the background scattering sources is required for effective suppression. The Multi-Grid thermal neutron detector is an Ar/CO$_{2}$ gas filled detector with a $^{10}$B$_{4}$C neutron converter coated on aluminium substrates. It is a large-area detector design that will equip inelastic neutron spectrometers at the European Spallation Source (ESS). To this end a …
Neutron and gamma-ray spectroscopy (NGRS) is a well established technique for studying the geochemical composition and volatile abundance relevant to planetary structure and evolution of planetary bodies. Previous NGRS instruments have used separate gamma-ray and neutron spectrometers. The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) instrument is an innovative and fully integrated NGRS with low resource requirements. EPICS utilizes elpasolite scintillator read out by silicon photomultipliers to combine the gamma-ray and neutron spectrometer into a single instrument, leading t…
Evaluation of a method for time-of-flight, wavelength and distance calibration for neutron scattering instruments by means of a mini-chopper and standard neutron monitors
The European Spallation Source (ESS) will provide long neutron pulses for experiments on a suite of different instruments. Most of these will perform neutron data acquisition in event mode, i.e. each detected neutron will be characterised by one absolute timestamp and pixel identifier pair. Slow controls metadata from EPICS, such as sample environment measurements and motor positions, will also be timestamped at their source, so that all data and metadata are streamed as a list of events instead of histograms. A flexible data aggregation and streaming system is being developed combining both o…
In this work we report on measurements of neutron absorption in supermirror coatings. The measurements were carried out using the SuperADAM instrument at the Institut Laue-Langevin and by measuring the gamma-ray production from m = 3 and m = 4 neutron supermirrors when illuminated by a beam of neutrons. The results provide a valuable validation for recent computational and theoretical work that can be used as input to Monte-Carlo radiation transport calculations for the design of the shielding of neutron scattering instruments.
Modelling instrumental response for neutron scattering experiments at CSNS
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Spallation Neutron Source Science Center(散裂中子源科学中心);University of Chinese Academy of Sciences(中国科学院大学)
A design study of a horizontal neutron reflectometer adapted to the general baseline of the long pulse European Spallation Source (ESS) is presented. The instrument layout comprises solutions for the neutron guide, high-resolution pulse shaping and beam bending onto a sample surface being so far unique in the field of reflectometry. The length of this instrument is roughly 55 m, enabling $δλ/ λ$ resolutions from 0.5% to 10%. The incident beam is focussed in horizontal plane to boost measurements of sample sizes of 1*1 cm{^2} and smaller with potential beam deflection in both downward and upwar…
An analytical method is presented with allows to estimate the energy resolution of time-of-flight neutron spectrometers, as well as its partial contributions, over a dynamical range that extends from the elastic line to the accessible inelastic regions. Such a method, already successfully applied in the past to the TOSCA and HET neutron inelastic scattering spectrometers installed at the ISIS neutron spallation source [A M Gaspar, PhD Thesis, Universidade Tecnica de Lisboa, 2004], is here applied to the high resolution time-of-flight spectrometer TOFTOF, mainly dedicated to quasi-elastic neutr…
The MAPS direct geometry time-of-flight chopper spectrometer at the ISIS pulsed neutron and muon source has been in operation since 1999 and its novel use of a large array of position-sensitive neutron detectors paved the way for a later generations of chopper spectrometers around the world. Almost two decades of experience of user operations on MAPS, together with lessons learned from the operation of new generation instruments, led to a decision to perform three parallel upgrades to the instrument. These were to replace the primary beamline collimation with supermirror neutron guides, to ins…
Due to the Helium-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection. The instruments need detectors with excellent neutron detection efficiency, high-rate capabilities and unprecedented spatial resolution. The Macromolecular Crystallography instrument (NMX) requires a position resolution in the order of 200 um over a wide angular range of incoming neutrons. Solid converters in combination with Micro Pattern Gaseous Detectors (…
Small-angle neutron scattering (SANS) is an experimental technique to detect material structures in the nanometer to micrometer range. The solution of the structural model constructed from SANS strongly depends on the accuracy of the reduced data. The time-of-flight (TOF) SANS data are dependent on the wavelength of the pulsed neutron source. Therefore, data reduction must be handled very carefully to transform measured neutron events into neutron scattering intensity. In this study, reduction algorithms for TOF SANS data are developed and optimized using simulated data from a virtual neutron …
Magnetic small-angle neutron scattering (SANS) is ideally suited to provide direct, reciprocal-space information of long-wavelength magnetic modulations, such as helicoids, solitons, merons, or skyrmions. SANS of such structures in thin films or micro-structured bulk materials is strongly limited by the tiny scattering volume vis a vis the prohibitively large background scattering by the substrate and support structures. Considering near-surface scattering closely above the critical angle of reflection, where unwanted signal contributions due to substrate or support structures becomes very sma…
The MIEZE (Modulation of Intensity with Zero Effort) technique is a variant of neutron resonance spin echo (NRSE), which has proven to be a unique neutron scattering technique for measuring with high energy resolution in magnetic fields. Its limitations in terms of flight path differences have already been investigated analytically for neutron beams with vanishing divergence. In the present work Monte-Carlo simulations for quasi-elastic MIEZE experiments taking into account beam divergence as well as the sample dimensions are presented. One application of the MIEZE technique could be a dedicat…
In this last of a series of three papers on the development of an advanced solid-state neutron polarizer, we present the final construction of the polarizer and the results of its commissioning. The polarizer uses spin-selective reflection of neutrons by interfaces coated with polarizing super-mirrors. The polarizer is built entirely in-house for the PF1B cold neutron beam facility at the Institut Max von Laue - Paul Langevin (ILL). It has been installed in the PF1B casemate and tested at real conditions. The average transmission for the "good" spin component is measured to be >30 %. The polar…
In any neutron scattering experiment the measurement of the position of the scattered neutrons and their respective velocities is necessary. In order to do so, a position sensitive detector as well as a way to determine the velocities is needed. Measuring the velocities can either be done by using only a single wavelength and therefore velocity or by creating pulses, where the start and end time of each pulse is known and registering the time of arrival at the detector, which is the case we want to consider here. This pulse shaping process in neutron scattering instruments is usually done by u…
The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. The instruments are being selected from conceptual proposals submitted by groups from around Europe. These instruments present numerous challenges for detector technology in the absence of the availability of Helium-3, which is the default choice for detectors for instruments built until today and due to the extreme rates expected across the ESS instrument suite. Additionally a new generation of source requires a new generation of detector technologies to fully exploi…
The design and characteristics of the new very small angle neutron scattering spectrometer under construction at the Laboratoire Leon Brillouin is described. Its goal is to extend the range of scattering vectors magnitudes towards 2x10{-4} /A. The unique feature of this new spectrometer is a high resolution two dimensional image plate detector sensitive to neutrons. The wavelength selection is achieved by a double reflection supermirror monochromator and the collimator uses a novel multibeam design.
Kinetic small-angle neutron scattering provides access to the microscopic properties of mesoscale systems under slow, periodic perturbations. By interlocking the phases of neutron pulse, sample modulation, and detector signal, so-called Time-Involved Small Angle Neutron scattering Experiments (TISANE) allow to exploit the neutron velocity spread and record data without major sacrifice in intensity at time-scales down to micro-seconds. We review the optimization strategies of TISANE that arise from specific aspects of the process of data acquisition and data analysis starting from the basic pri…
The first eight years of operation of the Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge is being reviewed. The instrument has been part of the facility user program since 2009, and more than 250 individual user experiments have been performed to date. CNCS is an extremely powerful and versatile instrument and offers leading edge performance in terms of beam intensity, energy resolution, and flexibility to trade one for another. Experiments are being routinely performed with the sample at extreme conditions: T~0.05K, p>=2GPa and B=8T can be achieved indi…
The European Spallation Source is being constructed in Lund, Sweden and is planned to be the world's brightest pulsed spallation neutron source for cold and thermal neutron beams ($\le$ 1 eV). The facility uses a 2 GeV proton beam to produce neutrons from a tungsten target. The neutrons are then moderated in a moderator assembly consisting of both liquid hydrogen and water compartments. Surrounding the moderator are 22 beamports, which view the moderator's outside surfaces. The beamports are connected to long neutron guides that transport the moderated neutrons to the sample position via refle…
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting rates, while the investigation of sub-millimeter protein crystals will only be possible with large-area detectors that can achieve a position resolution as low as 200 μm. This has motivated an extensiv…
The European Spallation Source (ESS) in Lund, Sweden is just entering the construction phase with 3 neutron instruments having started in its design concept phase in 2014. As a collaboration of 17 European countries the majority of hardware devices for neutron instrumentation will be provided in-kind. This presents numerous technical and organisational challenges for the construction and the integration of the instruments into the facility wide infrastructure; notably the EPICS control network with standardised hardware interfaces and the facilities absolute timing system. Additionally the new…
In Chinese Spallation Neutron Source (CSNS), proton beam is used to hit metal tungsten target, and then high flux neutron are generated for experiments on instruments. For neutron flux spectrum correction, the current of proton beam is for each instrument. A real time monitor system is developed in CSNS, to monitor, broadcast and record each pulse of proton. Each proton pulse charge is measured and marked with high-precision timestamp. Then, the result of measurement will be broadcasted to control room and each neutron instrument. In control room, the proton charge of each pulse is listened an…
The European Spallation Source ESS is being constructed in Lund, Sweden, to be the world's brightest cold pulsed spallation neutron source. The facility uses a 2GeV proton beam hitting a target to produce neutrons. The neutrons are then thermalized in a moderator. Surrounding the moderator are several beam ports connected to neutron guides that transport the cold neutrons. Due to the long-pulse source nature of the ESS, neutron scattering instruments are significantly longer than at most existing facilities, with approximately half the instruments requiring neutron guides that are 150 meters l…
Very Small Angle Neutron Scattering (VSANS) is an upgrade of the traditional Small Angle Neutron Scattering (SANS) technique which can cover three orders of magnitude of length scale from one nanometer to one micrometer. It is a powerful tool for structure calibration in polymer science, biology, material science and condensed matter physics. Since the first VSANS instrument, D11 in Grenoble, was built in 1972, new collimation techniques, focusing optics (multi-beam converging apertures, material or magnetic lenses, and focusing mirrors) and higher resolution detectors combined with the long f…
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototyp…
Among Super-Mirror (SM) polarizers, solid-state devices have many advantages. The most relevant is 5-10 times smaller length compared to air-gap polarizers allowing to apply stronger magnetic fields. An important condition for a good SM polarizer is the matching of the substrate SLD (Scattering Length Density) with the SM coating SLD for spin-down neutrons. For traditional Fe/Si SM on Si substrate, this SLD step is positive when a neutron goes from the substrate to the SM, which leads to a significant loss of the polarizer performance at small Q. Instead, we use single-crystal Sapphire/Quartz …
Many types of neutron spectrometer use a conventional primary spectrometer consisting of some collimator, a crystal monochromator and a second collimator. Conventional resolution descriptions use instrument parameter values to deduce the beam character and thence the instrument transmission and resolution. This article solves the inverse problem of choosing beam elements to deliver some desired beam character and shows that there are many possible choices of elements to deliver any given beam character. Dealing with this multiplicity seems to be a central issue in the search for optimal instru…
The high performance requirements at the European Spallation Source have been driving the technological advances on the neutron detector front. Now more than ever is it important to optimize the design of detectors and instruments, to fully exploit the ESS source brilliance. Most of the simulation tools the neutron scattering community has at their disposal target the instrument optimization until the sample position, with little focus on detectors. The ESS Detector Group has extended the capabilities of existing detector simulation tools to bridge this gap. An extensive software framework has…
We provide the first demonstration that a neutron far-field interferometer can be employed to measure the microstructure of a sample. The interferometer is based on the moiré pattern of two phase modulating gratings which was previously realized in hard x-ray and visible light experiments. The autocorrelation length of this interferometer, and hence the microstructure length scale that is probed, is proportional to the grating spacing and the neutron wavelength, and can be varied over several orders of magnitude for one pair of gratings. We compare our measurements of the change in visibility …
McStas and Mantid are two well established software frameworks within the neutron scattering community. McStas has been primarily used for simulating the neutron transport of instruments, while Mantid has been primarily used for data reduction. We report here the status of our work done on the interoperability between the instrument simulation software McStas and the data reduction software Mantid. This provides a demonstration of how to successfully link together two software that otherwise have been developed independently, and in particular here show how this has been achieved for an instru…
The small-angle neutron scattering instruments at the Oak Ridge National Laboratory High Flux Isotope Reactor recently upgraded the area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors, based on the design used on the EQ-SANS instrument at ORNL Spallation Neutron Source. The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. T…
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC, is based on the nucleus recoil detector principle. The measurement strategy requires track reconstruction of recoiling nuclei down to a few keV, which can be achieved with a low pressure gaseous detector using a micro-pattern gaseous detector. A gas mixture, mainly isobutane, is used as a n-p …