基于形貌图像的多针尖扫描隧道显微镜纳米针尖定位

Nanoscale tip positioning with a multi-tip scanning tunneling microscope using topography images

A. Leis, V. Cherepanov, B. Voigtländer, F. S. Tautz

摘要:

多针尖扫描隧道显微镜(STM)是在纳米尺度上进行电荷输运测量的有力手段。利用位于样品表面的四个STM针尖,可以在专用几何配置中进行四点电阻测量。在这里,我们提出了一种替代最常用的扫描电子显微镜(SEM)成像来推断相应的尖端位置。在由光学显微镜监测的初始粗定位之后,STM扫描本身用于确定尖端间距离。一个大的STM概览扫描作为参考图。在参考标测图和小比例尺图像中识别具有单个尖端的相同地形特征,允许识别尖端位置,对于约1 $μ$ m的典型尖端间距,精度约为20 nm。为了校正STM的压电元件的非线性偏转、蠕变和滞后等效应,必须进行仔细的校准。

英文摘要:

Multi-tip scanning tunneling microscopy (STM) is a powerful method to perform charge transport measurements at the nanoscale. With four STM tips positioned on the surface of a sample, four-point resistance measurements can be performed in dedicated geometric configurations. Here, we present an alternative to the most often used scanning electron microscope (SEM) imaging to infer the corresponding tip positions. After initial coarse positioning monitored by an optical microscope, STM scanning itself is used to determine the inter-tip distances. A large STM overview scan serves as a reference map. Recognition of the same topographic features in the reference map and in small scale images with the individual tips allows to identify the tip positions with an accuracy of about 20 nm for a typical tip spacing of ~1 $μ$m. In order to correct for effects like the non-linearity of the deflection, creep and hysteresis of the piezo-electric elements of the STM, a careful calibration has to be performed.