Point by point strain scanning is often used to map the residual stress (strain) in engineering materials and components. However, the gauge volume and hence spatial resolution is limited by the beam defining apertures and can be anisotropic for very low and high diffraction (scattering) angles. Alternatively, wavelength resolved neutron transmission imaging has a potential to retrieve information tomographically about residual strain induced within materials through measurement in transmission of Bragg edges - crystallographic fingerprints whose locations and shapes depend on microstructure and strain distribution. In such a case the spatial resolution is determined by the geometrical blurring of the measurement setup and the detector point spread function. Mathematically, reconstruction of strain tensor field is described by the longitudinal ray transform; this transform has a non-trivial null-space, making direct inversion impossible. A combination of the longitudinal ray transform with physical constraints was used to reconstruct strain tensor fields in convex objects. To relax physical constraints and generalise reconstruction, a recently introduced concept of histogram tomography can be employed. Histogram tomography relies on our ability to resolve the distribution of strain in the beam direction, as we discuss in the paper. More specifically, Bragg edge strain tomography requires extraction of the second moment (variance about zero) of the strain distribution which has not yet been demonstrated in practice. In this paper we verify experimentally that the second moment can be reliably measured for a previously well characterised aluminium ring and plug sample. We compare experimental measurements against numerical calculation and further support our conclusions by rigorous uncertainty quantification of the estimated mean and variance of the strain distribution.
100 MHz high-speed strain monitor using fiber Bragg grating and optical filter applied for magnetostriction measurements of cobaltite at magnetic fields beyond 100 T
Enhanced spectral range of strain-induced tuning of quantum dots in circular Bragg grating cavities
Julius-Maximilians-Universität Würzburg(维尔茨堡大学);Würzburg-Dresden Cluster of Excellence ct.qmat(维尔茨堡-德累斯顿卓越集群 ct.qmat);University of Freiburg(弗莱堡大学);Centre for Nanosciences and Nanotechnologies CNRS, Universite Paris-Saclay(巴黎萨克雷大学法国国家科学研究中心纳米科学与技术中心);Karlsruhe Institute of Technology (KIT)(卡尔斯鲁厄理工学院)
Note: Optical filter method for high-resolution magnetostriction measurement using fiber Bragg grating under millisecond-pulsed high magnetic fields at cryogenic temperatures
Measurement of the angle dependence of magnetostriction in pulsed magnetic fields using a piezoelectric strain gauge
提出了一种在低温下测量毫秒级脉冲磁场中磁致伸缩的高分辨率方法,灵敏度为$1.11\times10^{-11}/\sqrt{\rm Hz}$。将样品粘合到薄压电板,使得当样品的长度改变时,其使压电体应变并引起电压变化。这种方法比光纤布拉格光栅方法更灵敏。它可以同时测量两个轴而不是一个轴。该真空计体积小,用途广泛,可在直流和毫秒脉冲磁场中工作。我们证明了它的使用通过测量钙$_3$钴$_{1.03}$锰$_{0.97}$ O $_6$单晶在脉冲磁场中的磁致伸缩。通过比较我们的数据,新的和以前发表的结果从光纤布拉格光栅磁致伸缩设置,我们确认,这种方法检测磁致伸缩效应。我们还证明了这种技术的小尺寸和多功能性,通过测量角度依赖于在65 T毫秒脉冲磁场中的转子探头中施加的磁场。