摘要:
在2.2 K、35 ms脉冲强磁场、45 T下,采用光学滤波法作为光纤光栅应变监测器的检测方案,对$ΔL/L\sim10^{-6}$进行了5 MHz的高分辨率磁致伸缩测量。对于毫秒脉冲磁场,磁致伸缩的分辨率与基于FBG的磁致伸缩测量系统的常规报道值大约相同数量级。测量速度是传统测量速度的$\sim$ 100倍。本系统可以作为传统的基于FBG的毫秒脉冲强磁场磁致伸缩测量系统的快速替代方案。
英文摘要:
High-resolution magnetostriction measurement of $ΔL/L\sim10^{-6}$ at a speed of 5 MHz is performed, using optical filter method as the detection scheme for the fiber Bragg grating (FBG) based strain monitor is performed under 35-millisecond pulsed high magnetic fields up to 45 T at 2.2 K. The resolution of magnetostriction is about the same order as the conventionally reported value from FBG based magnetostriction measurement systems for millisecond pulsed magnetic fields. The measurement speed is $\sim$100 times the conventional ones. Present system can be a faster alternative for the conventional FBG based magnetostriction measurement system for millisecond pulsed high magnetic fields.