本研究开发了基于EPI读出和深度学习重建的临床CEST-MRF方法,用于脑肿瘤定量,在≤2分钟内实现快速、准确且可重复的成像,并在患者中验证了其临床实用性。

摘要:

目的:开发一种临床适用的CEST磁共振指纹识别(CEST-MRF)方法,用于脑肿瘤定量,采用EPI采集和深度学习重建。方法:将最初为动物成像设计的CEST-MRF脉冲序列进行修改,以适应临床扫描仪的硬件限制,同时保持扫描时间≤2分钟。使用深度重建网络(DRONE)进行定量MRF重建,以获得水弛豫和化学交换参数。在数字脑体模的模拟中测试了6参数DRONE重建的可行性。对一名健康受试者进行了CEST-MRF序列、常规MRF和CEST序列的扫描以进行比较。通过重测实验评估可重复性,并计算白质(WM)和灰质(GM)的一致性相关系数(CCC)。CEST-MRF的临床实用性在4名脑转移瘤患者中通过与标准临床成像序列的比较得到验证。肿瘤被分割为水肿、实性核心和坏死核心区域,并将CEST-MRF值与对侧进行比较。结果:数字体模的DRONE重建对所有参数的归一化均方根误差≤7%。CEST-MRF参数与常规MRF和CEST序列及既往研究结果高度一致。所有6个参数的平均CCC在WM中为0.98±0.01,在GM中为0.98±0.02。几乎所有肿瘤区域的CEST-MRF值彼此之间以及与对侧相比均有显著差异(P=0.05)。结论:EPI读出与深度学习重建的结合实现了脑肿瘤中快速、准确且可重复的CEST-MRF。

英文摘要:

$\textbf{Purpose}$: To develop a clinical CEST MR fingerprinting (CEST-MRF) method for brain tumor quantification using EPI acquisition and deep learning reconstruction. $\textbf{Methods}$: A CEST-MRF pulse sequence originally designed for animal imaging was modified to conform to hardware limits on clinical scanners while keeping scan time $\leq$ 2 minutes. Quantitative MRF reconstruction was performed using a deep reconstruction network (DRONE) to yield the water relaxation and chemical exchange parameters. The feasibility of the 6 parameter DRONE reconstruction was tested in simulations in a digital brain phantom. A healthy subject was scanned with the CEST-MRF sequence, conventional MRF and CEST sequences for comparison. Reproducibility was assessed via test-retest experiments and the concordance correlation coefficient (CCC) calculated for white matter (WM) and grey matter (GM). The clinical utility of CEST-MRF was demonstrated in 4 patients with brain metastases in comparison to standard clinical imaging sequences. Tumors were segmented into edema, solid core and necrotic core regions and the CEST-MRF values compared to the contra-lateral side. $\textbf{Results}$: The DRONE reconstruction of the digital phantom yielded a normalized RMS error of $\leq$ 7% for all parameters. The CEST-MRF parameters were in good agreement with those from conventional MRF and CEST sequences and previous studies. The mean CCC for all 6 parameters was 0.98$\pm$0.01 in WM and 0.98$\pm$0.02 in GM. The CEST-MRF values in nearly all tumor regions were significantly different (P=0.05) from each other and the contra-lateral side. $\textbf{Conclusion}$: Combination of EPI readout and deep learning reconstruction enabled fast, accurate and reproducible CEST-MRF in brain tumors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑