AI总结:

本文提出GAN-CEST框架,利用生成对抗网络从缩减数据中重建定量三维半固态MT/CEST参数图,将采集时间缩短70%,并在多中心、多病种数据上验证了其高精度与鲁棒性。

摘要:

目的:大幅缩短定量三维化学交换饱和转移(CEST)和半固态磁化转移(MT)成像所需的采集时间,并实现快速的化学交换参数图重建。方法:使用3T临床扫描仪在3个不同地点、采用3种不同扫描仪型号和线圈,采集了L-精氨酸体模、健康志愿者全脑和腓肠肌以及癌症患者和心脏病患者的三维CEST和MT磁共振指纹(MRF)数据集。随后设计并训练了一个生成对抗网络监督框架(GAN-CEST),用于学习从缩减的输入数据空间到定量交换参数空间的映射,同时保留感知内容和定量内容。结果:GAN-CEST的三维采集时间为42-52秒,比CEST-MRF缩短了70%。全脑的定量重建耗时0.8秒。真实值与基于GAN的L-精氨酸浓度和pH值之间观察到极好的一致性(Pearson's r > 0.97,NRMSE < 1.5%)。来自脑肿瘤受试者的GAN-CEST图像得到的半固态体积分数和交换率的NRMSE分别为3.8±1.3%和4.6±1.3%,SSIM分别为96.3±1.6%和95.0±2.4%。对一名心脏病患者的腓肠肌交换参数进行映射,半固态交换参数的NRMSE < 7%,SSIM > 94%。在存在较大磁化率伪影的区域,与MRF相比,GAN-CEST表现出更好的性能和更低的噪声。结论:GAN-CEST能够大幅缩短定量半固态MT/CEST映射的采集时间,即使在面对训练期间未出现的病理情况和扫描仪型号时仍能保持性能。

英文摘要:

Purpose: To substantially shorten the acquisition time required for quantitative 3D chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) imaging and allow for rapid chemical exchange parameter map reconstruction. Methods: Three-dimensional CEST and MT magnetic resonance fingerprinting (MRF) datasets of L-arginine phantoms, whole-brains, and calf muscles from healthy volunteers, cancer patients, and cardiac patients were acquired using 3T clinical scanners at 3 different sites, using 3 different scanner models and coils. A generative adversarial network supervised framework (GAN-CEST) was then designed and trained to learn the mapping from a reduced input data space to the quantitative exchange parameter space, while preserving perceptual and quantitative content. Results: The GAN-CEST 3D acquisition time was 42-52 seconds, 70% shorter than CEST-MRF. The quantitative reconstruction of the entire brain took 0.8 seconds. An excellent agreement was observed between the ground truth and GAN-based L-arginine concentration and pH values (Pearson's r > 0.97, NRMSE < 1.5%). GAN-CEST images from a brain-tumor subject yielded a semi-solid volume fraction and exchange rate NRMSE of 3.8$\pm$1.3% and 4.6$\pm$1.3%, respectively, and SSIM of 96.3$\pm$1.6% and 95.0$\pm$2.4%, respectively. The mapping of the calf-muscle exchange parameters in a cardiac patient, yielded NRMSE < 7% and SSIM > 94% for the semi-solid exchange parameters. In regions with large susceptibility artifacts, GAN-CEST has demonstrated improved performance and reduced noise compared to MRF. Conclusion: GAN-CEST can substantially reduce the acquisition time for quantitative semisolid MT/CEST mapping, while retaining performance even when facing pathologies and scanner models that were not available during training.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑