arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.03317stat.MLcs.AIcs.LGphysics.med-ph
收藏

在定量分子MRI中使用物理结构变分自编码器(PS-VAE)进行多参数不确定性映射

Multiparameter Uncertainty Mapping in Quantitative Molecular MRI using a Physics-Structured Variational Autoencoder (PS-VAE)

School of Biomedical Engineering, Tel-Aviv University(生物医学工程学院,特拉维夫大学);School of Biochemistry, Neurobiology, and Biophysics, Tel-Aviv University(生物化学、神经生物学与生物物理学学院,特拉维夫大学);Institute of Neuroradiology, University Hospital Erlangen(神经放射学研究所,埃朗根大学医院);Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU)(生物医学工程人工智能系,弗赖堡-艾尔朗根-纽伦堡大学(FAU));Sagol School of Neuroscience, Tel-Aviv University(萨戈尔神经科学学院,特拉维夫大学)

Alex Finkelstein, Ron Moneta, Or Zohar, Michal Rivlin, Moritz Zaiss, Dinora Friedmann Morvinski, Or Perlman

AI总结:

本文提出了一种物理结构变分自编码器,用于快速提取MRI中多参数后验分布,提高定量分子MRI的不确定性和透明度。

摘要:

定量成像方法,如磁共振指纹(MRF),旨在通过从信号演变中估计生物物理组织参数来提取可解释的病理生物标记物。然而,此类逆问题中使用的模式匹配算法或神经网络往往缺乏系统性的不确定性量化,这限制了其在临床应用中的可信度和透明度。本文描述了一种用于快速提取体素级多参数后验分布的物理结构变分自编码器(PS-VAE)。我们的方法集成了可微的自旋物理模拟器与自监督学习,并提供了一个完整的协方差矩阵,以捕捉潜在生物物理空间中参数间的相关性。该方法在多质子池化学交换饱和转移(CEST)和半固体磁化转移(MT)分子MRF研究中得到了验证,涵盖了体外假体、肿瘤携带小鼠、健康人类志愿者以及一名胶质瘤患者。所得的多参数后验分布与通过暴力法贝叶斯分析计算的结果一致,同时在全脑量化方面提供了数量级的加速。此外,我们展示了通过逐步获取的信号监控多参数后验动态,如何为协议优化提供实用见解,并可能促进实时自适应采集。

英文摘要:

Quantitative imaging methods, such as magnetic resonance fingerprinting (MRF), aim to extract interpretable pathology biomarkers by estimating biophysical tissue parameters from signal evolutions. However, the pattern-matching algorithms or neural networks used in such inverse problems often lack principled uncertainty quantification, which limits the trustworthiness and transparency, required for clinical acceptance. Here, we describe a physics-structured variational autoencoder (PS-VAE) designed for rapid extraction of voxelwise multi-parameter posterior distributions. Our approach integrates a differentiable spin physics simulator with self-supervised learning, and provides a full covariance that captures the inter-parameter correlations of the latent biophysical space. The method was validated in a multi-proton pool chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) molecular MRF study, across in-vitro phantoms, tumor-bearing mice, healthy human volunteers, and a subject with glioblastoma. The resulting multi-parametric posteriors are in good agreement with those calculated using a brute-force Bayesian analysis, while providing an orders-of-magnitude acceleration in whole brain quantification. In addition, we demonstrate how monitoring the multi-parameter posterior dynamics across progressively acquired signals provides practical insights for protocol optimization and may facilitate real-time adaptive acquisition.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑