arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2101.11495physics.ins-detastro-ph.HEastro-ph.IM
收藏

用于KATRIN实验的前向光束监测器

Forward Beam Monitor for the KATRIN experiment

A. Beglarian, E. Ellinger, N. Haußmann, K. Helbing, S. Hickford, U. Naumann, H. -W. Ortjohann, M. Steidl, J. Wolf, S. Wüstling

摘要:

\textit{KArlsruhe TRItium Neutrino}(KATRIN)实验旨在测量中微子质量,灵敏度为\SI{0.2}{\electronvolt}(\SI{90}{\percent} CL)。这将通过精确测量氚衰变的$\upbeta$电子谱的终点区域来实现。$\upbeta$ -电子在\textit{Windowless Gaseous Tritium Source}(WGTS)中产生,并被磁性引导通过束线。为了准确地提取中微子质量,要求源的活性是稳定的,并以高精度已知。因此,WGTS受到多个测量系统的持续广泛监测。\textit{Forward Beam Monitor}(FBM)就是这样一种监测系统。FBM系统包括一个复杂的机械装置,能够将探测器板插入KATRIN光束线,定位精度优于\SI{0.3}{\milli\metre}。该位置处的电子通量密度为\SI{e6}{\per\second\per\milli\metre\squared}的量级。探测器板包含两个\pin二极管类型的硅探测器芯片,其可以测量来自源的$\upbeta$ -电子通量,其精度为\SI{60}{\second}内的\SI{0.1}{\percent},能量分辨率为FWHM $=$ \SI{2}{\kilo\electronvolt}。开发FBM的独特挑战来自其低温泵送部分内的指定操作环境,该环境是在\SI{1}{\tesla}强磁场存在下的低温温度下的潜在氚污染超高真空室。这些参数中的每一个都强烈地限制了可能材料的选择,这例如在检测器降噪、散热和润滑方面造成困难。为了从束管中完全移除FBM,需要\SI{2}{\meter}长距离行进到束线中,这要求具有鲁棒性以及高精度的移动机构。

英文摘要:

The \textit{KArlsruhe TRItium Neutrino} (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of \SI{0.2}{\electronvolt} (\SI{90}{\percent} CL). This will be achieved by a precision measurement of the endpoint region of the $\upbeta$-electron spectrum of tritium decay. The $\upbeta$-electrons are produced in the \textit{Windowless Gaseous Tritium Source} (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The \textit{Forward Beam Monitor} (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than \SI{0.3}{\milli\metre}. The electron flux density at that position is on the order of \SI{e6}{\per\second\per\milli\metre\squared}. The detector board contains two silicon detector chips of \pin diode type which can measure the $\upbeta$-electron flux from the source with a precision of \SI{0.1}{\percent} within \SI{60}{\second} with an energy resolution of FWHM $=$ \SI{2}{\kilo\electronvolt}. The unique challenge in developing the FBM arise from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a \SI{1}{\tesla} strong magnetic field. Each of theses parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a \SI{2}{\meter} long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑