The \textit{KArlsruhe TRItium Neutrino} (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of \SI{0.2}{\electronvolt} (\SI{90}{\percent} CL). This will be achieved by a precision measurement of the endpoint region of the $\upbeta$-electron spectrum of tritium decay. The $\upbeta$-electrons are produced in the \textit{Windowless Gaseous Tritium Source} (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The \textit{Forward Beam Monitor} (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than \SI{0.3}{\milli\metre}. The electron flux density at that position is on the order of \SI{e6}{\per\second\per\milli\metre\squared}. The detector board contains two silicon detector chips of \pin diode type which can measure the $\upbeta$-electron flux from the source with a precision of \SI{0.1}{\percent} within \SI{60}{\second} with an energy resolution of FWHM $=$ \SI{2}{\kilo\electronvolt}. The unique challenge in developing the FBM arise from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a \SI{1}{\tesla} strong magnetic field. Each of theses parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a \SI{2}{\meter} long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism.
A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment
KATRIN实验的目标是以200 meV/c^2(90% C. L.)的灵敏度确定中微子质量尺度。通过精确测量氚$β$ -光谱在端点区域的形状。衰变电子的能量分析是通过MAC-E滤波谱仪实现的。为了确定KATRIN主谱仪的透射特性,研制了一种单能角选择电子源。在准备主光谱仪的第二次调试阶段时,在KATRIN监测光谱仪上进行了测量阶段,其中设备在MAC-E过滤器设置中运行以进行测试。这些测量的结果进行了比较,使用粒子跟踪软件“Kassiopeia”,这是在KATRIN合作开发的模拟在最近几年。
Forecasting Source Stability in Scientific Experiments using Temporal Learning Models: A Case Study from Tritium Monitoring
Institute for Data Processing(数据处理研究所);Schmalkalden University of Applied Sciences(施马尔卡尔登应用科学大学);Technical University Munich(慕尼黑技术大学);Max-Planck-Institut für Kernphysik(马克斯·普朗克核物理研究所)