arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1802.05227physics.ins-det
收藏

通过KATRIN实验中$^{83\mathrm{m}}$ Kr转换电子线的差异校准ppm级高压

Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment

M. Arenz, W. -J. Baek, M. Beck, A. Beglarian, J. Behrens, T. Bergmann, A. Berlev, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, N. Bu… 展开作者

M. Arenz, W. -J. Baek, M. Beck, A. Beglarian, J. Behrens, T. Bergmann, A. Berlev, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, N. Buzinsky, S. Chilingaryan, W. Q. Choi, M. Deffert, P. J. Doe, O. Dragoun, G. Drexlin, S. Dyba, F. Edzards, K. Eitel, E. Ellinger, R. Engel, S. Enomoto, M. Erhard, D. Eversheim, M. Fedkevych, S. Fischer, J. A. Formaggio, F. M. Fränkle, G. B. Franklin, F. Friedel, A. Fulst, W. Gil, F. Glück, A. Gonzalez Ureña, S. Grohmann, R. Grössle, R. Gumbsheimer, M. Hackenjos, V. Hannen, F. Harms, N. Haußmann, F. Heizmann, K. Helbing, W. Herz, S. Hickford, D. Hilk, D. Hillesheimer, M. A. Howe, A. Huber, A. Jansen, J. Kellerer, N. Kernert, L. Kippenbrock, M. Kleesiek, M. Klein, A. Kopmann, M. Korzeczek, A. Kovalík, B. Krasch, M. Kraus, L. Kuckert, T. Lasserre, O. Lebeda, J. Letnev, A. Lokhov, M. Machatschek, A. Marsteller, E. L. Martin, S. Mertens, S. Mirz, B. Monreal, H. Neumann, S. Niemes, A. Off, A. Osipowicz, E. Otten, D. S. Parno, A. Pollithy, A. W. P. Poon, F. Priester, P. C. -O. Ranitzsch, O. Rest, R. G. H. Robertson, F. Roccati, C. Rodenbeck, M. Röllig, C. Röttele, M. Ryšavý, R. Sack, A. Saenz, L. Schimpf, K. Schlösser, M. Schlösser, K. Schönung, M. Schrank, H. Seitz-Moskaliuk, J. Sentkerestiová, V. Sibille, M. Slezák, M. Steidl, N. Steinbrink, M. Sturm, M. Suchopar, M. Suesser, H. H. Telle, L. A. Thorne, T. Thümmler, N. Titov, I. Tkachev, N. Trost, K. Valerius, D. Vénos, R. Vianden, A. P. Vizcaya Hernández, M. Weber, C. Weinheimer, C. Weiss, S. Welte, J. Wendel, J. F. Wilkerson, J. Wolf, S. Wüstling, S. Zadoroghny

摘要:

中微子质量实验KATRIN要求主谱仪在-18.6 kV处的阻滞电位稳定性为3 ppm。为了监控稳定性,我们与德国国家计量机构Physikalisch-Technische Bundesanstalt(PTB)合作开发并制造了两台定制的超精密高压分压器。到目前为止,分压器的定期绝对校准需要将设备带到专业的计量实验室。在这里,我们提出了一种新的方法,该方法基于使用KATRIN装置测量两条$^{83\mathrm{m}}$ Kr转换电子线的能量差,该方法在2017年7月KATRIN的调试测量期间进行了演示。测量的高压分压器K35的比例因子$M=1972.449(10)$与四年前的PTB校准一致。该结果证明了校准方法的实用性以及分压器的长期稳定性。

英文摘要:

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑