The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this time may be too long; however, researchers usually are interested only on certain region within the matrix of pixels. In this paper we present the development of a smart skipper readout technique that allows the user to specify regions of interest of the CCD matrix where an arbitrary (high) number of measurements of the same charge can taken to obtain the desired noise level, and far less measurements are performed in those regions that are less interesting to the researcher, therefore reducing the total readout time.
We present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, $1.35$ Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with $\approx 130$ grams of active mass and $346$ Mpix), is part of the R$\&$D effort of the OSCURA experiment which will have $\appro…
The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$μ$m $\times$ 50$μ$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successi…
Skipper-CCD can achieve deep sub-electron readout noise making possible the absolute determination of the exact number of ionized electrons in a large range, from 0 to above 1900 electrons. In this work we present a novel technique that exploits this unique capability to allow self-calibration and the ultimate determination of silicon properties. We performed an absolute measurement of the variance and the mean number of the charge distribution produced by $^{55}$Fe X-rays, getting a Fano factor absolute measurement in Si at 123K and 5.9 keV. A value of 0.119 $\pm$ 0.002 was found and the elec…
The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the detector in a low-energy X-ray detection experiment.
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the o…
With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI), and at the same time, it averages the multiple samples producing at its output the pixel value with sub-electron noise. For this prupose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experiment…
Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) are an important technology to probe neutrino and light-dark-matter interactions due to their sub-electron read-out noise. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, prod…
A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference
Instituto Balseiro(巴尔塞罗研究所);Instituto de Nanociencia y Nanotecnología INN (CNEA-CONICET)(纳米科学与技术研究所(CNEA-CONICET));Fermi National Accelerator Laboratory(费米国家加速器实验室);Universidad Nacional de Córdoba(科尔多瓦国立大学);Comisión Nacional de Energía Atómica (CNEA)(国家原子能委员会);CONICET(阿根廷国家科学研究委员会)
Characterization of Spurious Charge in SENSEI Skipper-CCDs
C.N. Yang Institute for Theoretical Physics, Stony Brook University(纽约州立大学石溪分校杨振宁理论物理研究所);Department of Physics and Astronomy, Stony Brook University(纽约州立大学石溪分校物理与天文学系);Department of Physics and Institute for Fundamental Science, University of Oregon(俄勒冈大学物理与基础科学研究所);Fermi National Accelerator Laboratory(费米国家加速器实验室);Département de Physique, Université de Montréal(蒙特利尔大学物理系);Instituto de Inv. en Ing. Eléctrica (IIIE), Dpto. de Ingeniería Eléctrica y de Computadoras (DIEC), Universidad Nacional del Sur (UNS)-CONICET(国立苏尔大学电气与计算机工程系电气研究研究所(IIIE)-阿根廷科学与技术研究委员会);Department of Astronomy and Astrophysics, University of Chicago(芝加哥大学天文与天体物理学系);Brookhaven National Laboratory(布鲁克海文国家实验室);School of Physics and Astronomy, Tel-Aviv University(特拉维夫大学物理与天文学学院)
Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an ima…
We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)…
We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-en…
We present new direct-detection constraints on eV-to-GeV dark matter interacting with electrons using a prototype detector of the Sub-Electron-Noise Skipper-CCD Experimental Instrument. The results are based on data taken in the MINOS cavern at the Fermi National Accelerator Laboratory. We focus on data obtained with two distinct readout strategies. For the first strategy, we read out the Skipper-CCD continuously, accumulating an exposure of 0.177 gram-days. While we observe no events containing three or more electrons, we find a large one- and two-electron background event rate, which we attr…
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete sub-electron readout noise has been achieved reproducibly over millions of pixels on a stable, large-area detector. This allows the precise counting of the number of electrons in each pixel, ranging from pixels with 0 electrons to more than 1500 electrons. The resulting CCD detector is thus an ultra-sensitive calorimeter. It is also capable of counting single pho…
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experi…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. A test stand for measuring the charge transfer inefficiency (CTI) of a prototy…
Position-sensitive detectors for cold and ultra-cold neutrons (UCN) are in use in fundamental research. In particular, measuring the properties of the quantum states of bouncing neutrons requires micro-metric spatial resolution. To this end, a Charge Coupled Device (CCD) coated with a thin conversion layer that allows a real time detection of neutron hits is under development at LPSC. In this paper, we present the design and performance of a dedicated electronic board designed to read-out eight CCDs simultaneously and operating under vacuum.
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) Collaboration has been developing Column-Parallel CCDs for the vertex detector of a future Linear Collider which can be read out many times faster than standard CCDs. The most recent studies are of devices designed to reduce both the CCD's intergate capacitance and the clock voltages necessary to driv…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of the International Linear Collider (ILC). The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. The results of detailed simulations of the charge transfer inef…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. An Analytic Model has been developed for the determination of the charge trans…
This paper presents a preliminary study into the use of CCDs to image secondary scintillation light generated by THick Gas Electron Multipliers (THGEMs) in a two phase LAr TPC. A Sony ICX285AL CCD chip was mounted above a double THGEM in the gas phase of a 40 litre two-phase LAr TPC with the majority of the camera electronics positioned externally via a feedthrough. An Am-241 source was mounted on a rotatable motion feedthrough allowing the positioning of the alpha source either inside or outside of the field cage. Developed for and incorporated into the TPC design was a novel high voltage fee…
We present details of the design for the CCD readout electronics for the Subaru Telescope Prime Focus Spectrograph (PFS). The spectrograph is comprised of four identical spectrograph modules, each collecting roughly 600 spectra. The spectrograph modules provide simultaneous wavelength coverage over the entire band from 380 nm to 1260 nm through the use of three separate optical channels: blue, red, and near infrared (NIR). A camera in each channel images the multi-object spectra onto a 4k x 4k, 15 um pixel, detector format. The two visible cameras use a pair of Hamamatsu 2k x 4k CCDs with read…
Results of detailed simulations of the charge transfer inefficiency of a prototype serial readout CCD chip are reported. The effect of radiation damage on the chip operating in a particle detector at high frequency at a future accelerator is studied, specifically the creation of two electron trap levels, 0.17 eV and 0.44 eV below the bottom of the conduction band. Good agreement is found between simulations using the ISE-TCAD DESSIS program and an analytical model for the former level but not for the latter. Optimum operation is predicted to be at about 250 K where the effects of the traps is …
Current, state-of-the-art CCDs are close to being able to deliver all key performance figures for future strategic X-ray missions except for the required frame rates. Our Stanford group is seeking to close this technology gap through a multi-pronged approach of microelectronics, signal processing and novel detector devices, developed in collaboration with the Massachusetts Institute of Technology (MIT) and MIT Lincoln Laboratory (MIT-LL). Here we report results from our (integrated) readout electronics development, digital signal processing and novel SiSeRO (Single electron Sensitive Read Out)…
CCD was born in Bell Laboratories in 1969 and has been widely used in various fields. Its ultra-low noise and high quantum efficiency make it work well in particle physics, high energy physics, nuclear physics and astrophysics. Nowadays, more and more CCD cameras have been developed for medical diagnosis, scientific experiments, aerospace, military exploration and other fields. For the wide range of CCD cameras, a Non-vacuum-cooling compact (NVCC) scientific CCD camera has been developed, including FPGA-based low noise clock and bias driver circuit, data acquisition circuit, STM32-based temper…
We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a var…
X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft X-rays. These properties, along with the large arrays and small pixel sizes available with modern-day CCDs, make them a potential candidate for next generation astronomical X-ray missions equipped with large collecting areas, high angular resolutions and wide fields of view, enabling observation of the faint, diffuse and high redshift X-ray universe. However, …
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently …
Results of detailed simulations of the charge transfer inefficiency of a prototype CCD chip are reported. The effect of radiation damage in a particle detector operating at a future accelerator is studied by examining two electron trap levels, 0.17 eV and 0.44 eV below the bottom of the conduction band. Good agreement is found between simulations using the ISE-TCAD DESSIS program and an analytical model for the 0.17 eV level. Optimum operation is predicted to be at about 250 K where the effect of the traps is minimal which is approximately independent of readout frequency. This work has been c…
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout ASIC was confirmed to work correctly at slow readout speed (1.5 Mpix/sec). In this letter, we describe the status of the performance study for the readout ASIC.
We have developed a completely new type of general-purpose CCD data acquisition system which enables one to drive any type of CCD using any type of clocking mode. A CCD driver system widely used before consisted of an analog multiplexer (MPX), a digital-to-analog converter (DAC), and an operational amplifier. A DAC is used to determine high and low voltage levels and the MPX selects each voltage level using a TTL clock. In this kind of driver board, it is difficult to reduce the noise caused by a short of high and low level in MPX and also to select many kinds of different voltage levels. Rece…
We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with low-pressure triethylamine (TEA). Ionization electrons produced by energetic charged particles are three-dimensionally imaged by recording light from electron avalanches with an intensified CCD system. The detector permits to inves-tigate the spatial ionization distributions of particle tracks in gas, of equivalent length and resolution in tissue of 4 mm and 40 n…
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies betw…
In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits the effective spatial resolution to approximately 25μm, irrespective of the pixel size. For very low fluence the charge-cloud centroid determination can be used, on each individual spot, to estimate the actual photon impact position with sub-pixel precision. The readout noise and speed, together with the charge and spatial undersampling, are the main factor…
One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been developed. In this paper we will report on the performance of latest developed readout ASIC prototype as well as the outline of the design strategy for the next ASIC prototype.
Output-Stage Design Optimization for High-Sensitivity SiSeRO CCDs and SiSeRO Active Pixel Sensors
Kavli Institute of Astrophysics and Cosmology, Stanford University(斯坦福大学天体物理与宇宙学 Kavli 研究所);MIT Lincoln Laboratory(麻省理工学院林肯实验室);Department of Physics, Stanford University(斯坦福大学物理系);SLAC National Accelerator Laboratory(SLAC国家加速器实验室);Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology(麻省理工学院天体物理与空间研究 Kavli 研究所)
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgrounds from electron recoils. This paper demonstrates that a simplified CCD analysis achieves $7.3\times10^{-5}$ rejection of electron recoils while a charge analysis yields an electron rejection facto…
Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, conventional CDS circuit inevitably introduces new noises since it consists of several active analog components such as operational amplifiers. This paper proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit first, then implement the digital CDS algorithm …