Quantum-logic-based ${}^{27}\textrm{Al}^+$ optical clock has been demonstrated in several schemes as there are different choices of the auxiliary ion species. In this paper, we present the first detailed evaluation of the systematic shift and the total uncertainty of an ${}^{27}\textrm{Al}^+$ optical clock sympathetically cooled by a ${}^{40}\textrm{Ca}^+$ ion. The total systematic uncertainty of the ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ quantum logic clock has been estimated to be $7.9 \times 10^{-18}$, which was mainly limited by the uncertainty of the quadratic Zeeman shift. By comparing the frequency of two counter-propagating clock beams on the same ion, we measured the frequency stability to be $3.7 \times 10^{-14} /\sqrtτ$.
Electrometry is performed using Rydberg states to evaluate the quadratic Stark shift of the $5s^2$ $^1\textrm{S}_0-5s5p$ $^3\textrm{P}_0$ clock transition in strontium. By measuring the Stark shift of the highly excited $5s75d\;^1\textrm{D}_2$ state using electromagnetically induced transparency, we characterize the electric field with sufficient precision to provide tight constraints on the systematic shift to the clock transition. Using the theoretically derived, and experimentally verified, polarizability for this Rydberg state we can measure the residual field with an uncertainty well belo…
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the $^1S_0\leftrightarrow{}^3P_0$ transition in $^{27}$Al$^+$. By stabilizing the dominant sources of differential phase noise between …
Controlling light shifts in chip-scale atomic beam clocks
National Institute of Standards and Technology(美国国家标准与技术研究院);University of Colorado Boulder(科罗拉多大学博尔德分校);Infleqtion(英飞格蒂昂);HRL Laboratories(HRL实验室);DARPA(美国国防部高级研究计划局)
We propose and analyze a Cesium lattice optical clock (CLOC) which has the potential for high performance and simple operation in a compact form factor using a forbidden optical transition in Cs atoms at 685 nm. Cs atoms are trapped in a 3D optical lattice using a magic trap wavelength of $λ_{\textrm m}=803~\textrm nm$. To reduce sensitivity to magnetic fields the atoms are probed on two cycling transitions with equal magnitude, but opposite magnetic shifts. Operation of the clock requires only three diode lasers at 685, 803, 852 nm and is simplified compared to other higher-performance optica…
Deep laser cooling of atoms, ions, and molecules facilitates the study of fundamental physics as well as applied research. In this work, we report on the narrow-line laser cooling of thulium atoms at the wavelength of $506.2\,\textrm{nm}$ with the natural linewidth of $7.8\,\textrm{kHz}$, which widens the limits of atomic cloud parameters control. Temperatures of about $400\,\textrm{nK}$, phase-space density of up to $3.5\times10^{-4}$ and $2\times10^6$ number of trapped atoms were achieved. We have also demonstrated formation of double cloud structure in an optical lattice by adjusting parame…
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Op…
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. This work takes an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87Sr optical lattice clock now achieves fractional stability of 2.2e-16 at 1 s. With this improved stability, we perform a new accuracy evaluat…
Optical atomic clocks have already overcome the eighteenth decimal digit of instability and uncertainty demonstrating incredible control over external perturbations of the clock transition frequency. At the same time there is an increasing demand for atomic and ionic transitions with minimal sensitivity to external fields, with practical operational wavelengths and robust readout protocols. One of the goals is to simplify clock's operation maintaining its relative uncertainty at low 10-18 level. It is especially important for transportable and envisioned space-based optical clocks. We proved e…
A transportable optical clock refer to the $4s^2S_{1/2}-3d^2D_{5/2}$ electric quadrupole transition at 729 nm of single $^{40}Ca^+$ trapped in mini Paul trap has been developed. The physical system of $^{40}Ca^+$ optical clock is re-engineered from a bulky and complex setup to an integration of two subsystems: a compact single ion unit including ion trapping and detection modules, and a compact laser unit including laser sources, beam distributor and frequency reference modules. Apart from the electronics, the whole equipment has been constructed within a volume of 0.54 $m^3$. The systematic f…
Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at $10^{-18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\times 10^{-18}$.
An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios
Physikalisch-Technische Bundesanstalt(德国联邦物理技术研究院);Institut für Quantenoptik, Leibniz Universität Hannover(汉诺威莱布尼茨大学量子光学研究所);Laboratoire Kastler Brossel, Sorbonne Université, CNRS, ENS-PSL Research University, Collège de France(索邦大学、法国国家科学研究中心、巴黎文理研究大学、法兰西公学院卡斯特尔-布罗塞尔实验室)
We propose a new class of atomic microwave clocks based on the hyperfine transitions in the ground state of aluminum or gallium atoms trapped in optical lattices. For these elements magic wavelengths exist at which both levels of the hyperfine doublet are shifted at the same rate by the lattice laser field, cancelling its effect on the clock transition. Our analysis of various systematic effects shows that, while offering an improved control over systematic errors, the accuracy of the proposed microwave clock is competitive to that of the state-of-the-art primary frequency standard.
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order $10^{-16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the cont…
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This wor…
Optical atomic clocks represent the state-of-the-art in the frontier of modern measurement science. In this article we provide a detailed review on the development of optical atomic clocks that are based on trapped single ions and many neutral atoms. We discuss important technical ingredients for optical clocks, and we present measurement precision and systematic uncertainty associated with some of the best clocks to date. We conclude with an outlook on the exciting prospect for clock applications.
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice clock to 1.5x10-16, the clock frequency is measured against a hydrogen maser which is simultaneously calibrated to the US primary frequency standard, the NIST Cs fountain clock, NIST-F1. The comparison i…
$^{88}$Sr$^{+}$ optical clock with $7.9\times 10^{-19}$ systematic uncertainty and measurement of its absolute frequency with $9.8\times 10^{-17}$ uncertainty
The 7.6(5) eV nuclear magnetic-dipole transition in a single 229Th3+ ion may provide the foundation for an optical clock of superb accuracy. A virtual clock transition composed of stretched states within the 5F5/2 electronic ground level of both nuclear ground and isomeric manifolds is proposed. It is shown to offer unprecedented systematic shift suppression, allowing for clock performance with a total fractional inaccuracy approaching 1 x 10^-19.
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to $7.2 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF1 and $2.5 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF2 at high atom densi…
We examine the effect of a parasitic rf magnetic field, attributed to ion trapping, on the highly anticipated nuclear clock based on $^{229}$Th$^{3+}$ [C. J. Campbell et al., Phys. Rev. Lett. 108, 120802 (2012)]. The rf magnetic field induces an ac Zeeman shift to the clock frequency. As we demonstrate, this shift threatens to be the dominant systematic frequency shift for the clock, exceeding other systematic frequency shifts and the projected systematic uncertainty of the clock by orders of magnitude. We propose practical means to suppress or eliminate this shift.
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to aver…
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5$\times$10${}^{-19}$.
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic shifts (20 Hz uncertainty) in the absolute frequency measurement of 429 228 004 229 867 Hz. The high resolution permits an investigation of the optical lattice motional sideband structure. The local oscillator for this optical atomic clock is a stable diode laser with its Hz-level linewidth characterized across the optical spectrum using a femtosecond frequency…
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make us…
Here we present a liquid nitrogen-cooled Ca^+ optical clock with an overall systematic uncertainty of 3*10^-18. In contrast with the room-temperature Ca^+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion's secular (thermal) motion is reduced to < 1*10^-…
We analyze reactive collisions of a single Ba$^+$ ion in contact with an ultracold gas of Rb atoms at low three-body collision energies of 2.2(9) mK$\times k_{\mathrm{B}}$. Mapping out the Ba$^+$ loss rate dependence on the Rb atom density we can discern two-body reactive collisions from three-body ones and for the first time determine both rate coefficients which are $k_2=3.1(6)(6)\times 10^{-13}\textrm{cm}^{3}\textrm{s}^{-1}$ and $k_3=1.04(4)(45)\times 10^{-24}\textrm{cm}^{6}\textrm{s}^{-1}$, respectively (statistical and systematic errors in parenthesis). Thus, the measured ternary recombin…
Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal of a single atom. An increased number of ions can overcome this limitation and allow for the implementation of novel clock schemes. However, this presents the challenge to maintain the excellent control over systematic shifts of a single particle in spatially extended and strongly coupled many-body systems. We measure and deduce systematic frequency uncertain…
We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{\rm Hg}/ν_{\rm Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 \times 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.
We investigate systematic errors associated with a common modulation technique used for phase sensitive detection of a coherent population trapping (CPT) resonance. In particular, we show that modification of the CPT resonance lineshape due to the presence of off-resonant fields leads to frequency shifts which may limit the stability of CPT-based atomic clocks. We also demonstrate that an alternative demodulation technique greatly reduces these effects.
Improved systematic uncertainty evaluation of the $^{171}$Yb optical lattice clock NMIJ-Yb1 with uncertainty of $2.6\times10^{-17}$
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)(日本国家计量院(NMIJ),产业技术综合研究所(AIST));Department of Physics, Graduate School of Engineering Science, Yokohama National University(横滨国立大学工学研究科物理系)
We present a compact, long-term nearly continuous operation of a room-temperature Ca$^+$ optical clock setup towards a transportable clock, achieving an overall systematic uncertainty of $4.8\times 10^{-18}$ and an uptime rate of 97.8% over an 8-day period. The active liquid-cooling scheme is adopted, combined with the precise temperature measurement with 13 temperature sensors both inside and outside the vacuum chamber to ensure the accurate evaluation of the thermal environment for the optical clock. The environmental temperature uncertainty is evaluated as 293.31(0.4) K, corresponding to a …
We report a vapor-cell magneto-optical trapping of Hg isotopes on the ${}^1S_0-{}^3P_1$ intercombination transition. Six abundant isotopes, including four bosons and two fermions, were trapped. Hg is the heaviest non-radioactive atom trapped so far, which enables sensitive atomic searches for ``new physics'' beyond the standard model. We propose an accurate optical lattice clock based on Hg and evaluate its systematic accuracy to be better than $10^{-18}$. Highly accurate and stable Hg-based clocks will provide a new avenue for the research of optical lattice clocks and the time variation of t…
Due to the low sensitivity of the thulium optical clock to black-body radiation and good accuracy and stability estimations, it appears to be one of the most promising transportable optical clocks. One of the leading systematic effects for Tm clock transition, namely the second-order Zeeman effect, can be canceled by probing two clock transitions between different hyperfine levels of ground and metastable states during the clock operation. We prepare the atoms in $m_F=0$ state of both ground hyperfine levels simultaneously and excite alternately two clock transitions. Here we demonstrate effic…
Recent experimental progress in cooling, trapping, and quantum logic spectroscopy of highly-charged ions (HCIs) made HCIs accessible for high resolution spectroscopy and precision fundamental studies. Based on these achievements, we explore a possibility to develop optical clocks using transitions between the ground and a low-lying excited state in the Cf$^{15+}$ and Cf$^{17+}$ ions. Using a high-accuracy relativistic method of calculation we predicted the wavelengths of clock transitions, calculated relevant atomic properties, and analyzed a number of systematic effects (such as the electric …
We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman shift and vector light-shift cancellation techniques. By introducing both an H-maser and a Global Positioning System (GPS) carrier phase link, the absolute frequency of the $^1S_0(F=9/2) - {}^3P_0(F=9/2)$ clock transition of the $^{87}$Sr optical lattice clock is determined as 429,228,004,229,875(4) Hz, where the uncertainty is mainly limited by that of the…
We present a detailed experimental and theoretical study of the effect of nuclear spin on the performance of optical lattice clocks. With a state-mixing theory including spin-orbit and hyperfine interactions, we describe the origin of the $^1S_0$-$^3P_0$ clock transition and the differential g-factor between the two clock states for alkaline-earth(-like) atoms, using $^{87}$Sr as an example. Clock frequency shifts due to magnetic and optical fields are discussed with an emphasis on those relating to nuclear structure. An experimental determination of the differential g-factor in $^{87}$Sr is p…
We report on the design of a segmented linear Paul trap for optical clock applications using trapped ion Coulomb crystals. For an optical clock with an improved short-term stability and a fractional frequency uncertainty of 10^-18, we propose 115In+ ions sympathetically cooled by 172Yb+. We discuss the systematic frequency shifts of such a frequency standard. In particular, we elaborate on high precision calculations of the electric radiofrequency field of the ion trap using the finite element method. These calculations are used to find a scalable design with minimized excess micromotion of th…
Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced fr…
We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1$\times10^{-13}$/$\sqrtτ$, where $τ$ is the averaging time in seconds. The total systematic uncertainty is evaluated to be ${Δν/ ν= 9 \times 10^{-16}}$. Using the clock, we realize the first measurement of the ratio of the $D_{5/2}$ stat…
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on ${}^{115}$In${}^+$ / ${}^{172}$Yb${}^+$ Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of …
We propose here a few selective highly charged ions (HCIs), namely Ni$^{12+}$ and Cu$^{13+}$, Pd$^{12+}$ and Ag$^{13+}$, that not only promise to be very high accurate optical clocks below $10^{-19}$ uncertainties, but also offer quality factors larger than $10^{15}$ and yet possess simple atomic structures for the experimental set-up. Moreover, these ions have strong optical magnetic-dipole (M1) transitions than the previously proposed HCI clocks. They can be used for the cooling and detection techniques. To demonstrate the projected fractional uncertainties below $10^{-19}$ level, we have es…
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17…
As optical clocks are improved to reach the frequency uncertainty below the 10$^{-17}$ level, the frequency shift due to the blackbody radiation (BBR) has been one of the major systematic effects hindering further improvement. To evaluate the BBR shift of an Yb optical lattice clock at KRISS, we installed an in-vacuum BBR shield and made radiation thermometry using a black-coated-sphere thermal probe. After we quantitatively measured the conduction loss of the thermal probe and the effects of all the external radiation sources, we determined the temperature at the atom trap site with an uncert…
The singly-ionized lutetium has a number of fortuitous properties well suited for a design of an optical clock and corresponding applications. In this work, we study Lu+ properties relevant to a development of the clock using the relativistic high-precision method combining configuration interaction and the linearized coupled-cluster approaches. The systematic effects due to interaction of an external electric-field gradient with the quadrupole moment and the dynamic correction to the blackbody radiation shift are studied and uncertainties are estimated. The value of the 5d6s 1D_2 polarizabili…
Some new physics models of quantum gravity or dark matter predict drifts or oscillations of the fundamental constants. A relatively simple model relates molecular vibrations to the proton-to-electron mass ratio $μ$. Many vibrational transitions are at optical frequencies with prospects for use as highly accurate optical clocks. We give a brief summary of new physics models that lead to changes in $μ$ and the current limits on drifts and oscillation amplitudes. After an overview of laboratory procedures, we give examples of molecules with experiments currently in development or underway. These …
Al$^+$ ions optical clock is a very promising optical frequency standard candidate due to its extremely small blackbody radiation shift. It has been successfully demonstrated with indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al$^+$ ions optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al$^+$ ions traps are utilized. …
We study the prospects of using the electric quadrupole transitions from the ground states of Cu, Ag and Au to the metastable state $^2{\rm D}_{5/2}$ as clock transitions in optical lattice clocks. We calculate lifetimes, transition rates, systematic shifts, and demonstrate that the fractional uncertainty of the clocks can be similar to what is achieved in the best current optical clocks. The use of these proposed clocks for the search of new physics, such as time variation of the fine structure constant, search for low-mass scalar dark matter, violation of Local Position Invariance and violat…
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the S1/2-D5/2 electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency f_Ca+ = 411 042 129 776 393.2 (1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of three of the Cs standard. Future improvements are expected to lead to …