Monte Carlo (MC) simulation is considered the gold standard method for radiotherapy dose calculation. However, achieving high precision requires a large number of simulation histories, which is time consuming. The use of computer graphics processing units (GPUs) has greatly accelerated MC simulation and allows dose calculation within a few minutes for a typical radiotherapy treatment plan. However, some clinical applications demand real time efficiency for MC dose calculation. To tackle this problem, we have developed a real time, deep learning based dose denoiser that can be plugged into a current GPU based MC dose engine to enable real time MC dose calculation. We used two different acceleration strategies to achieve this goal: 1) we applied voxel unshuffle and voxel shuffle operators to decrease the input and output sizes without any information loss, and 2) we decoupled the 3D volumetric convolution into a 2D axial convolution and a 1D slice convolution. In addition, we used a weakly supervised learning framework to train the network, which greatly reduces the size of the required training dataset and thus enables fast fine tuning based adaptation of the trained model to different radiation beams. Experimental results show that the proposed denoiser can run in as little as 39 ms, which is around 11.6 times faster than the baseline model. As a result, the whole MC dose calculation pipeline can be finished within 0.15 seconds, including both GPU MC dose calculation and deep learning based denoising, achieving the real time efficiency needed for some radiotherapy applications, such as online adaptive radiotherapy.
Rethinking Cross-Dose PET Denoising: Mitigating Averaging Effects via Residual Noise Learning
IWR, Heidelberg University(海德堡大学IWR);Silicon Austria Labs(Silicon Austria实验室);College of Medicine and Biological Information Engineering, Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University(医学与生物信息工程学院,医学图像智能计算教育部重点实验室,东北大学);Department of Epidemiology & Global Health, Umeå University(流行病学与全球健康系,乌梅大学)
FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising
Institute of Science and Technology for Brain-inspired Intelligence and MOE Frontiers Center for Brain Science, Fudan University(脑启发智能科学技术研究所和脑科学前沿中心,复旦大学);Shanghai Key Lab of Intelligent Information Processing, School of Computer Science, Fudan University(智能信息处理上海市重点实验室,复旦大学计算机科学学院);School of Cyber Science and Engineering, Sichuan University(四川大学网络科学与工程学院);School of Biomedical Engineering, Shanghai Jiao Tong University(上海交通大学生物医学工程学院)
Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current image-based denoising methods tend to produce a blur effect on the final reconstructed results especially in high noise levels. In this paper, a deep learning based approach was proposed to mitigate this problem. An adversarially trained network and a sharpness detection network were trained to guide the training process. Experiments on both simulated and real …
FrequencyCT: Frequency Domain Self-supervised Low-dose CT Denoising
School of Information Engineering, Nanchang University(南昌大学信息工程学院);SKLMS, ICMSEC, Academy of Mathematics and Systems Science, Chinese Academy of Sciences(中国科学院数学与系统科学研究院SKLMS、ICMSEC)
ProSAC-CT: Progressive Spectral-Anatomical Co-Guided Multi-Stage Diffusion Model for Low-Dose CT Denoising
College of Medicine and Biological Information Engineering, Northeastern University(东北大学医学与生物信息工程学院);Tohoku University School of Medicine(东北大学医学院);State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center(华南肿瘤学国家重点实验室,中山大学肿瘤防治中心);AI Lab, Tohoku University Hospital(东北大学医院人工智能实验室)
Rensselaer Polytechnic Institute(伦斯勒理工学院);Sichuan University(四川大学);Harvard Medical School(哈佛医学院);West China Hospital, Sichuan University(四川大学华西医院)
Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the signal-to-noise ratio, and may compromise the image quality and the diagnostic performance. Recently, deep-learning-based algorithms have achieved promising results in low-dose CT denoising, especially convolutional neural network (CNN) and generative adversarial network (GAN). This article introduces a Contracting Path-based Convolutional Encoder-decoder (CPCE) network…
PPORLD-EDNetLDCT: A Proximal Policy Optimization-Based Reinforcement Learning Framework for Adaptive Low-Dose CT Denoising
Department of Computer Science and Engineering, United International University, Dhaka 1212, Bangladesh(United International University);Faculty of Science and Technology, Charles Darwin University, Casuarina, NT 0909, Australia(Charles Darwin University);Faculty of Science and Information Technology, Charles Darwin University, Sydney, NSW, Australia(Charles Darwin University)
Rensselaer Polytechnic Institute(伦斯勒理工学院);University of Massachusetts Lowell(马萨诸塞大学洛厄尔分校);Xian Jiaotong University(西安交通大学);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);West China Hospital(华西医院)
In this paper, we introduce a new CT image denoising method based on the generative adversarial network (GAN) with Wasserstein distance and perceptual similarity. The Wasserstein distance is a key concept of the optimal transform theory, and promises to improve the performance of the GAN. The perceptual loss compares the perceptual features of a denoised output against those of the ground truth in an established feature space, while the GAN helps migrate the data noise distribution from strong to weak. Therefore, our proposed method transfers our knowledge of visual perception to the image den…
MDAA-Diff: CT-Guided Multi-Dose Adaptive Attention Diffusion Model for PET Denoising
School of Biomedical Engineering, Southern Medical University(南方医科大学生物医学工程学院);School of Biomedical Engineering, Shanghai Jiao Tong University(上海交通大学生物医学工程学院);Nanfang PET Center, Nanfang Hospital Southern Medical University(南方医科大学南芳医院PET中心)
Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School(马萨诸塞州总医院与哈佛医学院戈登医学影像中心)
Image denoising techniques are essential to reducing noise levels and enhancing diagnosis reliability in low-dose computed tomography (CT). Machine learning based denoising methods have shown great potential in removing the complex and spatial-variant noises in CT images. However, some residue artifacts would appear in the denoised image due to complexity of noises. A cascaded training network was proposed in this work, where the trained CNN was applied on the training dataset to initiate new trainings and remove artifacts induced by denoising. A cascades of convolutional neural networks (CNN)…
UniPET: a universal network for high-quality PET image denoising across varied dose reduction factors
School of Biological Science and Medical Engineering(生物科学与医学工程学院);State Key Laboratory of Software Development Environment(软件开发环境国家重点实验室);Key Laboratory of Biomechanics, Mechanobiology of Ministry of Education(教育部生物力学与机械生物学重点实验室);Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University(北京生物医学工程先进创新中心,北航);Department of Biomedical Engineering(生物医学工程系);Department of Gynecology Oncology(妇科肿瘤科);National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital(国家癌症中心/国家癌症临床研究中心/癌症医院);Chinese Academy of Medical Sciences(中国医学科学院);Peking Union Medical College(北京协和医学院);Xiaomi Corporation(小米公司)
College of Computer Science, Sichuan University(四川大学计算机学院);National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University(四川大学视觉合成图形图像技术国家级重点实验室);Rensselaer Polytechnic Institute(伦斯勒理工学院)
To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method for low-dose CT via deep neural network without accessing original projection data. A deep convolutional neural network is trained to transform low-dose CT images towards normal-dose CT images, patch by patch. Visual and quantitative evaluation demonstrates a competing performance of the proposed method.
The extensive use of medical CT has raised a public concern over the radiation dose to the patient. Reducing the radiation dose leads to increased CT image noise and artifacts, which can adversely affect not only the radiologists judgement but also the performance of downstream medical image analysis tasks. Various low-dose CT denoising methods, especially the recent deep learning based approaches, have produced impressive results. However, the existing denoising methods are all downstream-task-agnostic and neglect the diverse needs of the downstream applications. In this paper, we introduce a…
University of Massachusetts, Lowell(马萨诸塞大学洛厄尔分校);Weill Cornell Medicine, Cornell University(康奈尔大学威尔康奈尔医学院)
Low-dose computed tomography (LDCT) denoising is an important problem in CT research. Compared to the normal dose CT (NDCT), LDCT images are subjected to severe noise and artifacts. Recently in many studies, vision transformers have shown superior feature representation ability over convolutional neural networks (CNNs). However, unlike CNNs, the potential of vision transformers in LDCT denoising was little explored so far. To fill this gap, we propose a Convolution-free Token2Token Dilated Vision Transformer for low-dose CT denoising. The CTformer uses a more powerful token rearrangement to en…
Neighbor2Inverse: Self-Supervised Denoising for Low-Dose Region-of-Interest Phase Contrast CT
Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, TU Munich(技术物理系主任,物理系,自然科学学院,慕尼黑技术大学);Munich Institute of Biomedical Engineering, TU Munich(慕尼黑生物医学工程研究所,慕尼黑技术大学);Institute for Diagnostic and Interventional Radiology, TUM Klinikum(诊断与介入放射学研究所,TUM医院);Institute for Advanced Study, TU Munich, 85748 Garching, Germany(高级研究研究所,慕尼黑技术大学,德国85748盖ARCHING);X-ray Imaging Group, School of Physics and Astronomy, Monash University, Australia(X射线成像组,物理与天文学学院,墨尔本大学,澳大利亚);School of Medicine and Robinson Research Institute, Adelaide University, and Respiratory and Sleep Medicine, Women’s and Children’s Hospital, Adelaide, Australia(医学学院和罗宾逊研究所,阿德莱德大学,以及呼吸与睡眠医学,妇女与儿童医院,阿德莱德,澳大利亚)
National Institute for Mathematical Sciences(国家数学科学研究所);Chungnam National University College of Medicine(忠南大学医学院);Chungnam National University Hospital(忠南大学医院);Tongji University(同济大学);Yonsei University(延世大学)
This paper proposes a deep learning-based denoising method for noisy low-dose computerized tomography (CT) images in the absence of paired training data. The proposed method uses a fidelity-embedded generative adversarial network (GAN) to learn a denoising function from unpaired training data of low-dose CT (LDCT) and standard-dose CT (SDCT) images, where the denoising function is the optimal generator in the GAN framework. This paper analyzes the f-GAN objective to derive a suitable generator that is optimized by minimizing a weighted sum of two losses: the Kullback-Leibler divergence between…
ASCON: Anatomy-aware Supervised Contrastive Learning Framework for Low-dose CT Denoising
Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University(复旦大学类脑智能科学与技术研究院);School of Cyber Science and Engineering, Sichuan University(四川大学网络空间安全学院)
Low-dose CT Denoising with Language-engaged Dual-space Alignment
Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University(复旦大学脑智能科学与技术研究院);Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute(伦斯勒理工学院生物技术与跨学科研究中心)
Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising
Nanchang University(南昌大学);School of Information Engineering, Nanchang University(南昌大学信息工程学院);School of Biomedical Engineering, Sun Yat-sen University(中山大学医学院)
Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but raises the noise level, affecting the quality of the images and their ultimate diagnostic value. One mitigation option is to consider pairs of low-dose and high-dose CT projections to train a denoising model using deep learning algorithms; however, such pairs are rarely available in practice. In this paper, we present a new self-supervised method for CT denoising…
Low dose computed tomography is a mainstream for clinical applications. How-ever, compared to normal dose CT, in the low dose CT (LDCT) images, there are stronger noise and more artifacts which are obstacles for practical applications. In the last few years, convolution-based end-to-end deep learning methods have been widely used for LDCT image denoising. Recently, transformer has shown superior performance over convolution with more feature interactions. Yet its ap-plications in LDCT denoising have not been fully cultivated. Here, we propose a convolution-free T2T vision transformer-based Enc…
Low-Dose Computed Tomography (LDCT) technique, which reduces the radiation harm to human bodies, is now attracting increasing interest in the medical imaging field. As the image quality is degraded by low dose radiation, LDCT exams require specialized reconstruction methods or denoising algorithms. However, most of the recent effective methods overlook the inner-structure of the original projection data (sinogram) which limits their denoising ability. The inner-structure of the sinogram represents special characteristics of the data in the sinogram domain. By maintaining this structure while d…
Due to the potential risk of inducing cancers, radiation dose of X-ray CT should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts usually occur due to photon starvation, beamhardening, etc, which decrease the reliability of diagnosis. Thus, high quality reconstruction from low-dose X-ray CT data has become one of the important research topics in CT community. Conventional model-based denoising approaches are, however, computationally very expensive, and image domain denoising approaches hardly deal with CT specific noise patterns. To address these issues…
In the past few decades, to reduce the risk of X-ray in computed tomography (CT), low-dose CT image denoising has attracted extensive attention from researchers, which has become an important research issue in the field of medical images. In recent years, with the rapid development of deep learning technology, many algorithms have emerged to apply convolutional neural networks to this task, achieving promising results. However, there are still some problems such as low denoising efficiency, over-smoothed result, etc. In this paper, we propose the Edge enhancement based Densely connected Convol…
Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a supervised architecture, which needs paired CT image of full dose and quarter dose, and the solution is highly dependent on specific measurements. In this work, we introduce Denoising Diffusion LDCT Model, dubbed as DDLM, generating noise-free CT image using conditioned sampling. DDLM uses pretrained model, and need no training nor tuning process, thus our proposal …
Gating is commonly used in PET imaging to reduce respiratory motion blurring and facilitate more sophisticated motion correction methods. In the applications of low dose PET, however, reducing injection dose causes increased noise and reduces signal-to-noise ratio (SNR), subsequently corrupting the motion estimation/correction steps, causing inferior image quality. To tackle these issues, we first propose a Siamese adversarial network (SAN) that can efficiently recover high dose gated image volume from low dose gated image volume. To ensure the appearance consistency between the recovered gate…
Low-dose computed tomography (LDCT) reduces the X-ray radiation but compromises image quality with more noises and artifacts. A plethora of transformer models have been developed recently to improve LDCT image quality. However, the success of a transformer model relies on a large amount of paired noisy and clean data, which is often unavailable in clinical applications. In computer vision and natural language processing fields, masked autoencoders (MAE) have been proposed as an effective label-free self-pretraining method for transformers, due to its excellent feature representation ability. H…
Computed tomography (CT) is a popular medical imaging modality in clinical applications. At the same time, the x-ray radiation dose associated with CT scans raises public concerns due to its potential risks to the patients. Over the past years, major efforts have been dedicated to the development of Low-Dose CT (LDCT) methods. However, the radiation dose reduction compromises the signal-to-noise ratio (SNR), leading to strong noise and artifacts that down-grade CT image quality. In this paper, we propose a novel 3D noise reduction method, called Structure-sensitive Multi-scale Generative Adver…
The explosive rise of the use of Computer tomography (CT) imaging in medical practice has heightened public concern over the patient's associated radiation dose. However, reducing the radiation dose leads to increased noise and artifacts, which adversely degrades the scan's interpretability. Consequently, an advanced image reconstruction algorithm to improve the diagnostic performance of low dose ct arose as the primary concern among the researchers, which is challenging due to the ill-posedness of the problem. In recent times, the deep learning-based technique has emerged as a dominant method…
University of Texas Southwestern Medical Centre(德克萨斯大学西南医学中心)
Despite the indispensable role of X-ray computed tomography (CT) in diagnostic medicine field, the associated ionizing radiation is still a major concern considering that it may cause genetic and cancerous diseases. Decreasing the exposure can reduce the dose and hence the radiation-related risk, but will also induce higher quantum noise. Supervised deep learning can be used to train a neural network to denoise the low-dose CT (LDCT). However, its success requires massive pixel-wise paired LDCT and normal-dose CT (NDCT) images, which are rarely available in real practice. To alleviate this pro…
Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning~(DL)-based methods were introduced, outperforming conventional denoising algorithms on this task due to their high model capacity. However, for the transition of DL-based denoising to clinical practice, these data-driven approaches must generalize robustly beyond the seen training data. We, therefore, propose a hybrid denoising approach consisting of a set of trainable joint bilateral filters (JBFs) combined with a co…
Lowering the radiation dose in computed tomography (CT) can greatly reduce the potential risk to public health. However, the reconstructed images from the dose-reduced CT or low-dose CT (LDCT) suffer from severe noise, compromising the subsequent diagnosis and analysis. Recently, convolutional neural networks have achieved promising results in removing noise from LDCT images; the network architectures used are either handcrafted or built on top of conventional networks such as ResNet and U-Net. Recent advance on neural network architecture search (NAS) has proved that the network architecture …
WIA-LD2ND: Wavelet-based Image Alignment for Self-supervised Low-Dose CT Denoising
School of Computer Science, Wuhan University(武汉大学计算机学院);School of Computer Science, Central China Normal University(华中师范大学计算机学院);University of Louisville(路易斯维尔大学)
Saratoga High School(萨拉托加高中);Stanford University(斯坦福大学)
CT image quality is heavily reliant on radiation dose, which causes a trade-off between radiation dose and image quality that affects the subsequent image-based diagnostic performance. However, high radiation can be harmful to both patients and operators. Several (deep learning-based) approaches have been attempted to denoise low dose images. However, those approaches require access to large training sets, specifically the full dose CT images for reference, which can often be difficult to obtain. Self-supervised learning is an emerging alternative for lowering the reference data requirement fa…
University of California Davis Medical Center(加州大学戴维斯分校医学中心)
Deep neural networks have a great potential to improve image denoising in low-dose computed tomography (LDCT). Popular ways to increase the network capacity include adding more layers or repeating a modularized clone model in a sequence. In such sequential architectures, the noisy input image and end output image are commonly used only once in the training model, which however limits the overall learning performance. In this paper, we propose a parallel-clone neural network method that utilizes a modularized network model and exploits the benefit of parallel input, parallel-output loss, and cl…
Low-dose CT has been a key diagnostic imaging modality to reduce the potential risk of radiation overdose to patient health. Despite recent advances, CNN-based approaches typically apply filters in a spatially invariant way and adopt similar pixel-level losses, which treat all regions of the CT image equally and can be inefficient when fine-grained structures coexist with non-uniformly distributed noises. To address this issue, we propose a Structure-preserving Kernel Prediction Network (StructKPN) that combines the kernel prediction network with a structure-aware loss function that utilizes t…
Okinawa Institute of Science and Technology (OIST)(冲绳科学技术大学院大学)
Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential pre-processing step for low dose Computed Tomographic (CT) reconstructions. We propose a novel sinogram denoising algorithm inspired by the modern field of signal processing on graphs. Graph based methods often perform better than standard filtering operations since they can exploit the signal structure. This makes the sinogram an ideal candidate for graph based denoising since …
School of Statistics and Data Science, Nankai University(南开大学统计与数据科学学院);The First Affiliated Hospital of Xi’an Jiaotong University(西安交通大学第一附属医院);Shanxi Engineering Research Center of Computational Imaging and Medical Intelligence(山西省计算成像与医学智能工程研究中心)
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院(KAIST));VUNO Corp.(VUNO公司);Chungnam National University College of Medicine(忠南大学医学院);Chungnam National University Hospital(忠南大学医院)
The acquisition conditions for low-dose and high-dose CT images are usually different, so that the shifts in the CT numbers often occur. Accordingly, unsupervised deep learning-based approaches, which learn the target image distribution, often introduce CT number distortions and result in detrimental effects in diagnostic performance. To address this, here we propose a novel unsupervised learning approach for lowdose CT reconstruction using patch-wise deep metric learning. The key idea is to learn embedding space by pulling the positive pairs of image patches which shares the same anatomical s…
Friedrich Alexander Universität Erlangen-Nürnberg(弗里德里希·亚历山大大学埃尔朗根-纽伦堡)
Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be an alternative instead of Standard dose CT imaging. However Low Dose CT imaging has a fundamental issue with noises within results compared to Standard Dose CT imaging. Currently, there are lots of attempts to erase the noises. Most of methods with artificial intelligence have many parameters and unexplained layers or a kind of black-box methods. Therefore, o…