arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2308.13072eess.IVcs.CV

基于高效去噪扩散概率模型的低剂量PET全剂量全身PET合成:PET Consistency Model

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Emory University(埃默里大学);Memorial Sloan Kettering Cancer Center(纪念斯隆凯特琳癌症中心);Medical University of South Carolina(南卡罗来纳医科大学)

Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao, Xiaofeng Yang

AI总结:

针对PET成像中图像质量与辐射剂量的权衡问题,提出基于扩散的PET-CM模型,通过PET-VIT网络学习一致性函数实现低剂量到全剂量PET的高效合成,在两种低剂量场景下均达到SOTA性能且速度提升12倍。

摘要:

目的:正电子发射断层扫描(PET)是广泛临床应用中常用的成像模态。PET成像最重要的权衡之一在于图像质量与辐射剂量之间:高图像质量伴随着高辐射暴露。所有临床应用都希望提升图像质量,同时需要尽量减少辐射暴露以降低患者风险。方法:我们提出PET Consistency Model(PET-CM),这是一种高效的基于扩散的方法,可从低剂量PET图像生成高质量的全剂量PET图像。它采用两步流程:在前向扩散过程中向全剂量PET图像添加高斯噪声,然后在反向扩散过程中使用PET Shifted-window Vision Transformer(PET-VIT)网络对其进行去噪。PET-VIT网络学习一个一致性函数,能够将高斯噪声直接去噪为清晰的全剂量PET图像。PET-CM实现了当前最优的图像质量,同时所需计算时间远少于其他方法。结果:在八分之一剂量与全剂量图像的对比实验中,PET-CM表现出优异性能,其归一化平均绝对误差(NMAE)为1.278±0.122%,峰值信噪比(PSNR)为33.783±0.824dB,结构相似性指数(SSIM)为0.964±0.009,归一化互相关(NCC)为0.968±0.011,高分辨率评分(HRS)为4.543,标准摄取值误差(SUV Error)为0.255±0.318%,每位患者的平均生成时间为62秒。与当前最优的基于扩散的模型相比,这是一项显著提升,PET-CM达到该结果的速度快12倍。同样,在四分之一剂量到全剂量的图像实验中,PET-CM取得了具有竞争力的结果,使用相同的生成流程,其NMAE为0.973±0.066%,PSNR为36.172±0.801dB,SSIM为0.984±0.004,NCC为0.990±0.005,HRS为4.428,SUV Error为0.151±0.192%,凸显了其在两种去噪场景下的高定量精度和临床精度。

英文摘要:

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑