arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2007.08766physics.opticsastro-ph.IMphysics.ins-det
收藏

宽带高频灵敏度的引力波探测器

Gravitational wave detectors with broadband high frequency sensitivity

Michael A. Page, Maxim Goryachev, Haixing Miao, Yanbei Chen, Yiqiu Ma, David Mason, Massimiliano Rossi, Carl D. Blair, Li Ju, David G. Blair, Albert Schliesser,… 展开作者

Michael A. Page, Maxim Goryachev, Haixing Miao, Yanbei Chen, Yiqiu Ma, David Mason, Massimiliano Rossi, Carl D. Blair, Li Ju, David G. Blair, Albert Schliesser, Michael E. Tobar, Chunnong Zhao

摘要:

引力波探测器在螺旋阶段观测到了中子星合并GW 170817,但1-5 kHz波段的灵敏度不足以观测到合并本身的预期核物质特征,以及黑洞形成的过程。这为改进1- 5 kHz灵敏度提供了强有力的动机,该灵敏度目前受到光子散粒散粒噪声的限制。通过信号再循环的谐振增强通常以带宽为代价来提高信噪比。光机械白光信号回收(WLSR)的概念已经提出,但迄今为止所有的方案都依赖于合适的超低机械损耗组件的开发。在这里,我们第一次展示了光机械谐振器结构,满足WLSR干涉仪的损失要求,应变灵敏度低于10 $^{-24}$ Hz $^{-1/2}$在几kHz。两个谐振器的实验数据相结合的4公里干涉仪类似于LIGO的分析模型,以证明灵敏度增强跨更宽的频带的中子星合并频率比双回收法布里-珀罗迈克尔逊探测器相同的长度。一种候选谐振器是通过声子晶体与环境声学隔离的氮化硅膜。另一种是支持体声波纵波的单晶石英透镜。光功率要求可以优选膜谐振器,尽管体声波谐振器给出稍微更好的热噪声性能。两者都可以作为现有检测器的附加组件来实现。

英文摘要:

The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Resonant enhancement by signal recycling normally improves the signal to noise ratio at the expense of bandwidth. The concept of optomechanical white light signal recycling (WLSR) has been proposed, but all schemes to date have been reliant on the development of suitable ultra-low mechanical loss components. Here for the first time we show demonstrated optomechanical resonator structures that meet the loss requirements for a WLSR interferometer with strain sensitivity below 10$^{-24}$ Hz$^{-1/2}$ at a few kHz. Experimental data for two resonators are combined with analytic models of 4km interferometers similar to LIGO, to demonstrate sensitivity enhancement across a much broader band of neutron star coalescence frequencies than dual-recycled Fabry-Perot Michelson detectors of the same length. One candidate resonator is a silicon nitride membrane acoustically isolated from the environment by a phononic crystal. The other is a single-crystal quartz lens that supports bulk acoustic longitudinal waves. Optical power requirements could prefer the membrane resonator, although the bulk acoustic wave resonator gives somewhat better thermal noise performance. Both could be implemented as add-on components to existing detectors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑