A transimpedance amplifier has been designed for scanning tunneling microscopy (STM). The amplifier features low noise (limited by the Johnson noise of the 1 GΩ feedback resistor at low input current and low frequencies), sufficient bandwidth for most STM applications (50 kHz at 35 pF input capacitance), a large dynamic range (0.1 pA--50 nA without range switching), and a low input voltage offset. The amplifier is also suited for placing its first stage into the cryostat of a low-temperature STM, minimizing the input capacitance and reducing the Johnson noise of the feedback resistor. The amplifier may also find applications for specimen current imaging and electron-beam-induced current measurements in scanning electron microscopy and as a photodiode amplifier with a large dynamic range. This paper also discusses the sources of noise including the often neglected effect of non-balanced input impedance of operational amplifiers and describes how to accurately measure and adjust the frequency response of low-current transimpedance amplifiers.
The cable capacitance in cryogenic and high vacuum applications of quartz tuning forks imposes severe constraints on the bandwidth and noise performance of the measurement. We present a single stage low noise transimpedance amplifier with a bandwidth exceeding 1 MHz and provide an in-depth analysis of the dependence of the amplifier parameters on the cable capacitance.
We present a thorough theoretical analysis and experimental study of the shot and electronic noise spectra of a balanced optical detector based on an operational amplifier (OA) connected in a transimpedance scheme. We identify and quantify the primary parameters responsible for the limitations of the circuit, in particular the bandwidth and shot-to-electronic noise clearance. We find that the shot noise spectrum can be made consistent with the second order Butterworth filter, while the electronic noise grows linearly with the second power of the frequency. Good agreement between the theory and…
We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 \,\textrm{MHz}$ and exhibits an input referred current noise of $1.2\,\textrm{pA}/\sqrt{\textrm{Hz}}$---marginally above the the theoretical limit of $1.0\,\textrm{pA}/\sqrt{\textrm{Hz}}$ set by the room temperature Johnson noise of the detector's $16\,\textrm{k}Ω$ transimpedance. As a result, the photodetector allows for shot-noise limited operation for input powers exceeding $14\,μ\textrm{W}$ at $461\,\textrm{nm}$ corresponding …
Silicon Photomultipliers (SiPMs) are an excellent candidate for the development of large-area light sensors. Large SiPM-based detectors require low-noise pre-amplifiers to maximize the signal coupling between the sensor and the readout electronics. This article reports on the development of a low-noise transimpedance amplifier sensitive to single-photon signals at cryogenic temperature. The amplifier is used to readout a 1 cm$^{2}$ SiPM with a signal to noise ratio in excess of 40.
The spectroscopic resolution of tunneling measurements performed with a scanning tunneling microscope is ultimately limited by the temperature at which the experiment is performed. To take advantage of the potential high spectroscopic resolution associated with operating an STM in a dilution refrigerator we have designed a room temperature tunnel current amplifier having very small back-action on the tunnel contact and allowing to nearly reach the predicted energy resolution. This design is a modification of the standard op-amp based tip-biasing current-voltage converter which implements diffe…
Two large-area, low noise, high speed fluorescence detectors have been built. One detector consists of a photodiode with an area of 28 mm x 28 mm and a low noise transimpedance amplifier. This detector has a input light-equivalent spectral noise density of less than 3 pW/Hz^1/2, can recover from a large scattered light pulse within 10 us, and has a bandwidth of at least 900 kHz. The second detector consists of a 16 mm diameter avalanche photodiode and a low-noise transimpedance amplifier. This detector has an input light-equivalent spectral noise density of 0.08 pW/Hz^1/2, also can recover fro…
We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the comprehensive characterization of the devices under test regarding noise, settling and burden voltage behavior as well as stability of the gain factor, and confirm the performance of the ULCA for use as small-current calibrator standard. Also, we present a further advanced setup for the calibration of transimpedance amplifiers. Accuracy limits for best elec…
This work studies the adverse effects, as regards noise, of immersing in water an integrating line piezoelectric detector devoted to optoacoustic imaging. We found that the sensor, in conjunction with the acoustic coupling medium (water), behaves as a resonant dielectric antenna. This phenomenon limits the performance of the system because it efficiently captures unwanted electromagnetic signals. The requirement of good acoustic coupling between the water and the sensor precluded the use of a standard metallic shielding enclosure. Therefore, we resorted to a silver-paint based electrical shiel…
A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further reduce electronic noise, a junction field-effect transistor(JFET) is connected between photodiodes and transimpedance amplifier to reduce the impact of amplifier leakage current. Benefit from these designs, the root-mean-square(RMS) of noise voltage is about 6 mV with a gain of 3.2E5 V/W, and it means an ultra-low noise equivalent power density of 2.2E-12 W/rtH…
We present here the straightforward implementation of pump-probe methods into existing scanning tunneling microscopy (STM) systems. Our method uses the waveform-sequencing abilities of a standard arbitrary waveform generator (AWG) and a simple mechanical relay switch that either connects the regular STM control electronics or the AWG to the STM system. Our upgrade further enables pulsed-ESR excitation for advanced STM based spin-resonance experiments. We demonstrate the technical implementation, signal detection using a lock-in amplifier, and cross-correlation measurements of DC/DC and DC/RF p…
The denominated surface charge scraping mechanism was discovered in 2014 by using a new Atomic Force Microscopy (AFM) based mode called Charge Gradient Microscopy. The measurements to probe such mechanism are achieved with the use of a current-to-voltage converter: a transimpedance amplifier (TIA). However, the use of an incorrect approximation, named Gain BandWidth Product (GBWP) to calculate TIAs BandWidth (BW) could mislead to an incorrect data interpretation. By measuring at higher frequencies than permitted, the amplifier is used as a current-to-voltage converter, in conditions where it b…
This paper discusses a detailed design approach to determine the optimal input impedance (Rin) and bandwidth (BW) for current preamplifiers in Front End Electronics (FEE) of high-accuracy time measurement systems used in particle detection. Our study shows the effect of the input impedance Rin including the parasitic interconnection inductances of bonding wires between the detector and the FEE. We explain also the development of a new mathematical model for the estimation of the timing jitter of the current preamplifier in the case of using a low capacitor detector (Cd) as diamond. Different s…
We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 $μ$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivi…