用弱值放大方法实现非理想探测器量子极限计量

Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification

Liang Xu, Zexuan Liu, Animesh Datta, George C. Knee, Jeff S. Lundeen, Yan-qing Lu, Lijian Zhang

摘要:

弱值放大(WVA)是一种放大超小物理效应的可扩展协议。然而,放大的结果必然会发生高度抑制的概率,导致广泛的辩论是否整体测量精度相比,传统的测量(CM)的提高。在这里,我们通过实验证明了WVA的明确的优点,克服了实际的限制,包括噪声和饱和的光检测,并保持一个大范围的输入光强度远远超出了动态范围的光电探测器的散粒噪声缩放精度。在我们的设置中,WVA实现的精度比CM高6倍。我们的研究结果为WVA在包括精密计量和商业传感器在内的小信号测量应用中的广泛使用扫清了道路。

英文摘要:

Weak value amplification (WVA) is a metrological protocol that amplifies ultra-small physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photo-detection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is six times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.