Polarization plays an important role in various time-domain astrophysics to understand the magnetic fields, geometry, and environments of spatially unresolved variable sources. In this paper we present the results of laboratory and on-sky testing of a novel dual-beam, dual-camera optical imaging polarimeter (MOPTOP) exploiting high sensitivity, low-noise CMOS technology and designed to monitor variable and transient sources with low systematic errors and high sensitivity. We present a data reduction algorithm that corrects for sensitivity variations between the cameras on a source-by-source basis. Using our data reduction algorithm, we show that our dual-beam, dual-camera technique delivers the benefits of low and stable instrumental polarization ($<0.05$\% for lab data and $<0.25$\% for on sky data) and high throughput while avoiding the additional sky brightness and image overlap problems associated with dual-beam, single-camera polarimeters.
We present the basic concept of a new astronomical instrument: SPARC4 - Simultaneous Polarimeter and Rapid Camera in 4 bands. SPARC4 combines in one instrument: (i) photometric and polarimetric modes; (ii) sub-second time-resolution in photometric mode and excellent time-resolution in polarimetric mode; (iii) simultaneous imaging in four broad-bands for both modes. This combination will make SPARC4 a unique facility for ground-based optical observatories. Presently, the project is in its conceptual design phase.
The SPTpol camera is a dichroic polarimetric receiver at 90 and 150 GHz. Deployed in January 2012 on the South Pole Telescope (SPT), SPTpol is looking for faint polarization signals in the Cosmic Microwave Background (CMB). The camera consists of 180 individual Transition Edge Sensor (TES) polarimeters at 90 GHz and seven 84-polarimeter camera modules (a total of 588 polarimeters) at 150 GHz. We present the design, dark characterization, and in-lab optical properties of the 150 GHz camera modules. The modules consist of photolithographed arrays of TES polarimeters coupled to silicon platelet a…
The Wide-Area Linear Optical Polarimeter (WALOP)-South instrument is an upcoming wide-field and high-accuracy optical polarimeter to be used as a survey instrument for carrying out the Polar-Areas Stellar Imaging in Polarization High Accuracy Experiment (PASIPHAE) program. Designed to operate as a one-shot four-channel and four-camera imaging polarimeter, it will have a field of view of $35\times 35$ arcminutes and will measure the Stokes parameters $I$, $q$, and $u$ in a single exposure in the SDSS-r broadband filter. The design goal for the instrument is to achieve an overall polarimetric me…
We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beamdisplacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the effic…
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray i…
A new astronomical photo-polarimeter that can measure linear polarization of point sources simultaneously in three spectral bands was designed and built in Indian Institute of Astrophysics. The polarimeter has a Calcite beam-displacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral band are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. The effective chopping frequency can be set to as high as 200 Hz. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the a…
Near-infrared Imager Spectrometer and Polarimeter (NISP) is a camera, an intermediate resolution spectrograph and an imaging polarimeter being developed for upcoming 2.5m telescope of Physical Research Laboratory at Mount Abu, India. NISP is designed to work in the Near-IR (0.8-2.5 micron) using a H2RG detector. Collimator and camera lenses would transfer the image from the focal plane of the telescope to the detector plane. The entire optics, mechanical support structures, detector-SIDECAR assembly will be cooled to cryo-temperatures using an open cycle Liquid Nitrogen tank inside a vacuum De…
A presentation at the SciNeGHE conference of the past achievements, of the present activities and of the perspectives for the future of the HARPO project, the development of a time projection chamber as a high-performance gamma-ray telescope and linear polarimeter in the e+e- pair creation regime.
A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 micron thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectanc…
The WALOP-South instrument will be mounted on the 1 m SAAO telescope in South Africa as part of the PASIPHAE program to carry out a linear imaging polarization survey of the Galactic polar regions in the optical band. Designed to achieve polarimetric sensitivity of $0.05~\%$ across a $35\times35$ arcminute field of view, it will be capable of measuring the Stokes parameters I, q and u in a single exposure in the SDSS-r broadband and narrowband filters between $0.5~μm - 0.7~μm$. For each measurement, four images of the full field corresponding to linear polarization angles of 0 deg, 45 deg, 90 …
To obtain full Stokes spectra in multi-wavelength windows simultaneously, we developed a new spectro-polarimeter on the Domeless Solar Telescope at Hida Observatory. The new polarimeter consists of a 60 cm aperture vacuum telescope on an altazimuth mount, an image rotator, a high dispersion spectrograph, polarization modulator and analyzer composed of a continuously rotating waveplate with a retardation nearly constant around 127$^{circ}$ in 500 - 1100 nm and a polarizing beam splitter located closely behind the focus of the telescope, fast and large format CMOS cameras and an infrared camera.…
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background (CMB). Its optical system couples a polarizing Fourier transform spectrometer to the sky to measure the differential signal between orthogonal linear polarization states from two co-pointed beams on the sky. The double differential nature of the four-port measurement mitigates beam-related systematic errors common to the two-port systems used in most CMB me…
We designed and built a new Four-Stokes-Parameter spectral line Polarimeter (FSPPol) for the Caltech Submillimeter Observatory (CSO). The simple design of FSPPol does not include any mirrors or optical components to redirect or re-image the radiation beam and simply transmits the beam to the receiver through its retarder plates. FSPPol is currently optimized for observation in the 200-260 GHz range and measures all four Stokes parameters, I, Q, U, and V. The very low level of instrument polarization makes it possible to obtain reliable measurements of the Goldreich-Kylafis effect in molecular …
The SPTpol camera is a two-color, polarization-sensitive bolometer receiver, and was installed on the 10 meter South Pole Telescope in January 2012. SPTpol is designed to study the faint polarization signals in the Cosmic Microwave Background, with two primary scientific goals. One is to constrain the tensor-to-scalar ratio of perturbations in the primordial plasma, and thus constrain the space of permissible inflationary models. The other is to measure the weak lensing effect of large-scale structure on CMB polarization, which can be used to constrain the sum of neutrino masses as well as oth…
We report the design concept and performance of a compact, light-weight, and economic imaging polarimeter, TRIPOL (the Triple Range Imager and POLarimeter), capable of simultaneous optical imagery and polarimetry. TRIPOL splits the beam from wavelength 400 to 830 nm into g'-, r'-, and i'-bands with two dichroic mirrors, and measures polarization with an achromatic half-waveplate and a wire-grid. The simultaneity makes TRIPOL a useful tool for small telescopes for photometry and polarimetry of time variable and wavelength dependent phenomena. TRIPOL is devised for a Cassegrain telescope of an a…
Multi-chroic polarization sensitive detectors offer an avenue to increase both the spectral coverage and sensitivity of instruments optimized for observations of the cosmic-microwave background (CMB) or sub-mm sky. We report on an effort to adapt the Truce Collaboration horn coupled bolometric polarimeters for operation over octave bandwidth. Development is focused on detectors operating in both the 90 and 150 GHz bands which offer the highest CMB polarization to foreground ratio. We plan to deploy an array of 256 multi-chroic 90/150 GHz polarimeters with 1024 TES detectors on ACTPol in 2013, …
Physical Research Laboratory's (PRL) Optical Polarimeter has been used on various telescopes in India since its development in-house in the mid 1980s. To make the instrument more efficient and effective we have designed the acquisition and control system and written the software to run on the GNU/Linux Operating System. CCD cameras have been used, in place of eyepieces, which allow to observe fainter sources with smaller apertures. The use of smaller apertures provides dramatic gains in the signal-to-noise ratio. The polarimeter is now fully automated resulting in increased efficiency. With th…
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we pr…
The Keck Array (SPUD) is a set of microwave polarimeters that observes from the South Pole at degree angular scales in search of a signature of Inflation imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The first three Keck Array receivers were deployed during the 2010-2011 Austral summer, followed by two new receivers in the 2011-2012 summer season, completing the full five-receiver array. All five receivers are currently observing at 150 GHz. The Keck Array employs the field-proven BICEP/BICEP2 strategy of using small, cold, on-axis refractive optics, providing exce…
We report on the optimization of the hard X-ray polarimeter X-Calibur for a high-altitude balloon-flight in the focal plane of the InFOCμS X-ray telescope from Fort Sumner (NM) in Fall 2013. X-Calibur combines a low-Z scintillator slab to Compton-scatter photons with a high-Z Cadmium Zinc Telluride (CZT) detector assembly to photo-absorb the scattered photons. The detector makes use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of order unity and reaches a sensitivity close to th…
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope. X-Calibur combines a low-Z scatterer with a CZT detector assembly to measure the polarization of 20-80keV X-rays making use of the fact that polarized photons scatter preferentially perpendicular to the electric field orientati…
We describe a new instrument capable of high precision ($10^{-5}$) polarimetric observations simultaneously in three passbands ($BVR$). The instrument utilizes electron-multiplied EM CCD cameras for high efficiency and fast image readout. The key features of DIPol-UF are: (i) optical design with high throughput and inherent stability; (ii) great versatility which makes the instrument optimally suitable for observations of bright and faint targets; (iii) control system which allows using the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observa…
WALOP-South: a four camera one shot imaging polarimeter for the PASIPHAE survey. Paper III -- PSF modelling
School for Physical Sciences, National Institute of Science Education and Research(国家科学教育与研究大学物理科学学院);Homi Bhabha National Institute(霍米·巴巴国家研究所);Astrophysics division, National Center for Nuclear Research(国家核研究中心天体物理学部);Inter-University Centre for Astronomy and Astrophysics(大学间天文学与天体物理学中心);South African Astronomical Observatory(南非天文台);Cahill Center for Astronomy and Astrophysics, California Institute of Technology(加州理工学院凯尔天体物理学中心);Institute of Astrophysics, Foundation for Research and Technology-Hellas(希腊基础研究与技术基金会天体物理研究所);Steward Observatory, University of Arizona(亚利桑那大学斯图尔德天文台)
We present the design and the preliminary on sky performance with respect to beams and pass-bands of a multichroic polarimeter array covering the 90 and 146 GHz Cosmic Microwave Background (CMB) bands and its enabling broadband optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array…
Imaging polarimetry is a powerful tool for detecting and characterizing exoplanets and circumstellar environments. Polarimetry allows a separation of the light coming from an unpolarized source such as a star and the polarized source such as a planet or a protoplanetary disk. Future facilities like SPHERE at the VLT or EPICS at the E-ELT will incorporate imaging polarimetry to detect exoplanets. The Extreme Polarimeter (ExPo) is a dual-beam imaging polarimeter that currently can reach contrast ratios of 10^5, enough to characterize circumstellar environments. We present the data reduction step…
In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device perform…
The Hokupa'a-85 curvature adaptive optics system components have been adapted to create a new AO-corrected coudé instrument at the 3.67m Advanced Electro-Optical System (AEOS) telescope. This new AO-corrected optical path is designed to deliver an f/40 diffraction-limited focus at wavelengths longer than 800nm. A new EMCCD-based dual-beam imaging polarimeter called InnoPOL has been designed and is presently being installed behind this corrected f/40 beam. The InnoPOL system is a flexible platform for optimizing polarimetric performance using commercial solutions and for testing modulation stra…
In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device perform…
We present the B-BOP instrument, a polarimetric camera on board the future ESA-JAXA SPICA far-infrared space observatory. B-BOP will allow the study of the magnetic field in various astrophysical environments thanks to its unprecedented ability to measure the linear polarization of the submillimeter light. The maps produced by B-BOP will contain not only information on total power, but also on the degree and the angle of polarization, simultaneously in three spectral bands (70, 200 and 350 microns). The B-BOP detectors are ultra-sensitive silicon bolometers that are intrinsically sensitive to …
The Galway Astronomical Stokes Polarimeter (GASP) is an ultra-high-speed, full Stokes, astronomical imaging polarimeter based upon a Division of Amplitude Polarimeter. It has been developed to resolve extremely rapid stochastic, millisecond variations in objects such as optical pulsars, RRATs and magnetic cataclysmic variables. GASP has no moving parts or modulated components, so the complete Stokes vector can be measured from just one exposure - making it unique to astronomy. Furthermore the time required for the determination of the full Stokes vector is limited only by the time resolution o…
We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices and pseudo-tracks exiting from them are identified. We study the various contributions to the single-photon angular resolution using Monte Carlo simulations and compare them with the experimental dat…
POLICAN is a near-infrared imaging linear polarimeter developed for the Cananea Near-infrared Camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico. POLICAN is mounted ahead of CANICA and consist of a rotating super-achromatic 1-2.7 micron half-wave plate (HWP) as the modulator and a fixed wire-grid polarizer as the analyzer. CANICA has a 1024 x 1024 HgCdTe detector with a plate scale of 0.32 arcsec/pixel and provides a field of view of 5.5 x 5.5 arcmin^2. The polarimetric observations are carried out by modulating the i…
Data products from high spectral resolution astronomical polarimeters are often limited by fringes. Fringes can skew derived magnetic field properties from spectropolarimetric data. Fringe removal algorithms can also corrupt the data if the fringes and object signals are too similar. For some narrow-band imaging polarimeters, fringes change the calibration retarder properties, and dominate the calibration errors. Systems-level engineering tools for polarimetric instrumentation require accurate predictions of fringe amplitudes, periods for transmission, diattenuation and retardance. The relevan…
Optical characterization of the BICEP array 150 and 220/270GHz CMB polarimeters in the 2026 season
Boston University(波士顿大学);Cardiff University(卡迪夫大学);SLAC National Accelerator Laboratory(斯坦福直线加速器中心);Kavli Institute for Particle Astrophysics and Cosmology, Stanford University(斯坦福大学卡弗里粒子天体物理与宇宙学研究所);University of British Columbia(不列颠哥伦比亚大学);Center for Astrophysics, Harvard & Smithsonian(哈佛史密森尼天体物理中心);California Institute of Technology(加州理工学院);University of Cincinnati(辛辛那提大学);Stanford University(斯坦福大学);Jet Propulsion Laboratory, California Institute of Technology(加州理工学院喷气推进实验室);Kavli Institute for Cosmological Physics, University of Chicago(芝加哥大学卡弗里宇宙物理学研究所);National Institute of Standards and Technology(美国国家标准与技术研究院);Argonne National Laboratory, High Energy Physics Division(阿贡国家实验室高能物理部);University of Minnesota(明尼苏达大学);Service des Basses Temperatures, Commissariat a l’Energie Atomique(法国原子能委员会低温服务处);University of Iceland(冰岛大学);Harvard University(哈佛大学);Grainger College of Engineering, University of Illinois Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校格兰杰工程学院);Minnesota Institute for Astrophysics, University of Minnesota(明尼苏达大学明尼苏达天体物理研究所)
BICEP3 is a small-aperture refracting cosmic microwave background (CMB) telescope designed to make sensitive polarization maps in pursuit of a potential B-mode signal from inflationary gravitational waves. It is the latest in the BICEP/Keck Array series of CMB experiments at the South Pole, which has provided the most stringent constraints on inflation to date. For the 2016 observing season, BICEP3 was outfitted with a full suite of 2400 optically coupled detectors operating at 95 GHz. In these proceedings we report on the far field beam performance using calibration data taken during the 2015…
We present a characterization of CasPol, a dual-beam polarimeter mounted at the 2.15 meter Jorge Sahade Telescope, located at the Complejo Astronómico El Leoncito, Argentina. The telescope is one of the few available meter-sized optical telescopes located in the Southern Hemisphere hosting a polarimeter. To carry out this work we collected photo-polarimetric data along five observing campaigns, the first one during January, 2014, and the remaining ones spread between August, 2017 and March, 2018. The data were taken through the Johnson-Cousins V, R and I filters. Along the campaigns, we observ…
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured …
The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale Cosmic Microwave Background (CMB) polarization from the South Pole in search of a primordial $B$-mode signature. This $B$-mode signal arises from primordial gravitational waves interacting with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio $r$. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of t…
Context. Remote sensing of weak and small-scale solar magnetic fields is of utmost relevance for a number of important open questions in solar physics. This requires the acquisition of spectropolarimetric data with high spatial resolution (0.1 arcsec) and low noise (1e-3 to 1e-5 of the continuum intensity). The main limitations to obtain these measurements from the ground, are the degradation of the image resolution produced by atmospheric seeing and the seeing-induced crosstalk (SIC). Aims. We introduce the prototype of the Fast Solar Polarimeter (FSP), a new ground-based, high-cadence polari…
The Spectro-Polarimeter (SP) of the Andrei B. Severny Solar Tower Telescope (STT) at the Crimean Astrophysical Observatory: Optical Design and Implementation
We present here the polarization system of the NIKA camera and give a summary of the main results obtained and performed studies on Orion and the Crab nebula. The polarization system was equipped with a room temperature continuously rotating multi-mesh half wave plate and a grid polarizer facing the NIKA cryostat window. NIKA even though less sensitive than NIKA2 had polarization capability in both 1 and 2 millimiter bands. NIKA polarization observations demonstrated the ability of such a technology in detecting the polarization of different targets, compact and extended sources like the Crab …
Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a drop in sensitivity to point sources below 1GeV. The polarisation information, which is carried by the azimuthal angle of the conversion plane, is lost for the same reasons. HARPO (Hermetic ARgon POl…
We analyze the generation of polarization cross-talk in Stokes polarimeters by atmospheric seeing, and its effects on the noise statistics of spectropolarimetric measurements for both single-beam and dual-beam instruments. We investigate the time evolution of seeing-induced correlations between different states of one modulation cycle, and compare the response to these correlations of two popular polarization modulation schemes in a dual-beam system. Extension of the formalism to encompass an arbitrary number of modulation cycles enables us to compare our results with earlier work. Even though…
A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present this data-taking run, which demonstrated the excellent performance of the HARPO TPC.